Tandem Trunking With Transfer Key - NEC UNIVERGE SV9100 Features And Specifications

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Method B – Tandem Trunking with Transfer Key:
Program
Program Name/Description
Number
Basic Trunk Data Setup – Transmit Gain
14-01-04
Level for Conference and Transfer Calls
Select the Transmit CODEC gain level used by
the trunk when it is part of an Unsupervised
Conference.
Basic Trunk Data Setup – Receive Gain
14-01-05
Level for Conference and Transfer Calls
Select the Receive CODEC gain level used by
the trunk when it is part of an Unsupervised
Conference.
Basic Trunk Data Setup – Trunk-to-Trunk
14-01-13
Transfer
For each trunk, enter 1 to enable loop
supervision.
15-07-01
Programmable Function Keys
Assign a function key for Transfer (code 06).
20-06-01
Class of Service for Extensions
Assign a Class of Service (1 ~ 15) to an
extension.
20-07-11
Class of Service Options (Administrator
Level) – Forced Trunk Disconnect (analog
trunk only)
Turn Off or On an extension user ability to use
Forced Trunk Disconnect. This allows the
extension user to disconnect an Unsupervised
Conference in progress.
20-11-14
Class of Service Options (Hold/Transfer
Service) – Trunk-to-Trunk Transfer
Restriction
Turn Off or On the Trunk-to-Trunk Transfer
Restriction. If enabled, Trunk-to-Trunk Transfer
is not possible.
20-11-21
Class of Service Options (Hold/Transfer
Service) – Restriction for Tandem Trunking
on Hang Up
Allow/Deny an extension user ability to set up a
tandem call automatically when they hang up.
20-13-10
Class of Service Options (Supplementary
Service) – Barge-In Monitor
Allow/Deny an extension user ability to set up a
tandem call automatically when they hang up.
Input Data
1 ~ 57 (-15.5dB ~ +12.5dB in
0.5dB intervals)
1 ~ 57 (-15.5dB ~ +12.5dB in
0.5dB intervals)
0 = Disable
1 = Enable
Line Key 1 ~ 48
0 ~ 99 (Normal Function Code
851 by default)
*
*
00 ~
99 (Appearance
Function Code) (Service Code
852 by default)
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
0 = Off
1 = On
0 = Off
1 = On
0 = Allow
1 = Deny
0 = Speech
1 = Monitor
1201
Default
32 (0dB)
16 (-8dB)
1
Extension port
101 = Class 15
All other
extension port =
Class 1
COS 1~14 = 0
COS 15 = 1
COS 1 ~ 15 = 0
COS 1 ~ 15 = 0
COS 1 ~ 15 = 0

Advertisement

Table of Contents
loading