NEC UNIVERGE SV9100 Features And Specifications page 1099

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Program
Program Name/Description
Number
DTMF Tone Receiver Setup – Start delay
80-03-02
time
Define the start delay time for DTMF Tone
Receiver.
DTMF Tone Receiver Setup – Min. detect
80-03-03
level
Define the minimum detection level for DTMF
Tone Receiver.
Input Data
0 ~ 255
(0.25ms ~ 64ms)
0 ~ 15
detect level 0:
-10dBm(0) to -25dBm(15)
detect level 1:
-15dBm(0) to -30dBm(15)
detect level 2:
-20dBm(0) to -35dBm(15)
detect level 3:
-25dBm(0) to -40dBm(15)
detect level 4:
-30dBm(0) to -45dBm(15)
detect level 5:
-35dBm(0) to -50dBm(15)
detect level 6:
-40dBm(0) to -55dBm(15)
detect level 7:
-45dBm(0) to -60dBm(15)
detect level 8:
-50dBm(0) to -65dBm(15)
detect level 9:
-55dBm(0) to -70dBm(15)
detect level 10:
-60dBm(0) to -75dBm(15)
detect level 11:
-65dBm(0) to -80dBm(15)
detect level 12:
-70dBm(0) to -85dBm(15)
detect level 13:
-75dBm(0) to -90dBm(15)
detect level 14:
-80dBm(0) to -95dBm(15)
detect level 15:
-85dBm(0) to -100dBm(15)
1099
Default
Type 1 ~ 5 = 0
Type 1 = 10
(-20dBm)
Type 2 ~ 3 = 15
(-25dBm)
Type 4 ~ 5 = 10
(-20dBm)

Advertisement