NEC UNIVERGE SV9100 Features And Specifications page 1113

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Program
Program Name/Description
Number
DTMF Tone Receiver Setup – Max. detect
80-03-04
level
Define the maximum detect levels for the DTMF
Tone Receiver.
DTMF Tone Receiver Setup – Forward twist
80-03-05
level
Define the forward twist levels for the DTMF
Tone Receiver.
DTMF Tone Receiver Setup – Backward
80-03-06
twist level
Define the backward twist levels for the DTMF
Tone Receiver.
DTMF Tone Receiver Setup – ON detect time
80-03-07
Define the on detect times for the DTMF Tone
Receiver.
DTMF Tone Receiver Setup – OFF detect
80-03-08
time
Define the off detect timer for the DTMF Tone
Receiver.
Input Data
0 ~ 15
detect level 0:
0dBm(0) to -15dBm(15)
detect level 1:
-5dBm(0) to -20dBm(15)
detect level 2:
-10dBm(0) to -25dBm(15)
detect level 3:
-15dBm(0) to -30dBm(15)
detect level 4:
-20dBm(0) to -35dBm(15)
detect level 5:
-25dBm(0) to -40dBm(15)
detect level 6:
-30dBm(0) to -45dBm(15)
detect level 7:
-35dBm(0) to -50dBm(15)
detect level 8:
-40dBm(0) to -55dBm(15)
detect level 9:
-45dBm(0) to -60dBm(15)
detect level 10:
-50dBm(0) to -65dBm(15)
detect level 11:
-55dBm(0) to -70dBm(15)
detect level 12:
-60dBm(0) to -75dBm(15)
detect level 13:
-65dBm(0) to -80dBm(15)
detect level 14:
-70dBm(0) to -85dBm(15)
detect level 15:
-75dBm(0) to -90dBm(15)
0 ~ 9 (1dB ~ 10dB)
0 ~ 9 (1dB ~ 10dB)
1 ~ 255 (15+ 15ms ~ 3825ms)
1 ~ 255 (15+ 15ms ~ 3825ms)
1113
Default
Type 1 ~ 5 = 2
(-2dBm)
Type 1~5 = 5
(6dBm)
Type 1~5 = 0
(1dBm)
Type 1~5 = 1
(30ms)
Type 1~5 = 1
(30ms)

Advertisement

Table of Contents
loading

Table of Contents