10-12-01
10-12-02
10-12-09
51-01-01
51-15
84-03-06
90-04
90-58
10-46-07
84-23
When network communication is down, an alarm is sent to the Attendant terminal informing of
the communication error on the network. Improvements also allow for a defined number of
network outages per clock hour before failing over.
When the Attendant telephone exists on a secondary system, alarm information is not
displayed on the Attendant telephone.
When Fail Over occurs between the Primary System and two or more Secondary Systems,
the Attendant telephone displays the System ID of the system that went into Fail-Over last.
When using InMail in a CCIS or Netlink network, 8-digit extensions and mailboxes are not
supported.
The SV9100 can recognize each system where the DT700 extension(s) are connected and
provide an Automatic Route Selection (ARS) COS based on the System (System ID) when
using NetLink.
When NetLink is enabled, synchronous ringing (Program 14-02-17) is automatically
disabled. Synchronous ringing is not supported in a NetLink environment.
All nodes in a NetLink network should have the same setting in Program 51-01-04.
Restrictions
Netlink is only supported between SV9100 systems.
Netlink is not supported between SV8100 and SV9100 systems.
The number of total ports depends on the Primary System.
System ID (Program 51-01-02) must be unique for each system in a NetLink network.
MIS can connect to the Primary (Main) site only.
Only one Voice Mail can be installed in a NetLink network.
In-Mail and VRS use the VMDB of the Primary (Main) site.
APSU can be installed in the Secondary (Remote) System, however the NetLink time zone
follows the Primary (Main) System.
Secondary systems must follow the primary CPU software settings for Mu-law/A-law within
CPU Reset Programs
Program
When Changed Using
Handset, WebPro, PCPro
Handset, WebPro, PCPro
Handset, WebPro, PCPro
Handset, WebPro, PCPro
WebPro, Handset Programming
Handset, WebPro, PCPro
Handset Programming
Handset Programming
PcPro
Handset, WebPro, PCPro