Method C – Tandem Trunking on Hang up:
Program
Program Name/Description
Number
Basic Trunk Data Setup – Transmit Gain
14-01-04
Level for Conference and Transfer Calls
Select the Transmit CODEC gain level used by
the trunk when it is part of an Unsupervised
Conference.
Basic Trunk Data Setup – Receive Gain
14-01-05
Level for Conference and Transfer Calls
Select the Receive CODEC gain level used by
the trunk when it is part of an Unsupervised
Conference.
Basic Trunk Data Setup – Trunk-to-Trunk
14-01-13
Transfer
For each trunk, enter 1 to enable loop
supervision.
20-06-01
Class of Service for Extensions
Assign a Class of Service (1 ~ 15) to an
extension.
20-07-11
Class of Service Options (Administrator
Level) – Forced Trunk Disconnect (analog
trunk only)
Turn Off or On an extension user ability to use
Forced Trunk Disconnect. This allows the
extension user to disconnect an Unsupervised
Conference in progress.
20-11-11
Class of Service Options (Hold/Transfer
Service) – Automatic On-Hook Transfer
Turn Off or On the Trunk-to-Trunk Transfer
Restriction. If enabled, Trunk-to-Trunk Transfer
is not possible.
20-11-14
Class of Service Options (Hold/Transfer
Service) – Trunk-to-Trunk Transfer
Restriction
Turn Off or On the Trunk-to-Trunk Transfer
Restriction. If enabled, Trunk-to-Trunk Transfer
is not possible.
20-11-21
Class of Service Options (Hold/Transfer
Service) – Restriction for Tandem Trunking
on Hang Up
Allow/Deny an extension user ability to set up a
tandem call automatically when they hang up.
System Options for Transfer – Trunk-to-
24-02-07
Trunk Transfer Release Warning Tone
This timer starts when a trunk begins talking
with another trunk (for example: Trunk-to-Trunk
Transfer, outgoing from trunk, Tandem
Trunking).
When this time expires, a warning tone is
heard. If Program 24-02-10 is set, the
conversation disconnects after time expires.
This time is set again when the external digit
time expires. One of the trunks used must be
an analog trunk (or leased line).
Input Data
1 ~ 57 (-15.5dB ~ +12.5dB in
0.5dB intervals)
1 ~ 57 (-15.5dB ~ +12.5dB in
0.5dB intervals)
0 = Disable
1 = Enable
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
0 = Off
1 = On
0 = Off
1 = On
0 = Off
1 = On
0 = Allow
1 = Deny
0 ~ 64800 seconds
1203
Default
32 (0dB)
16 (-8dB)
1
Extension port
101 = Class 15
All other
extension port =
Class 1
COS 1~14 = 0
COS 15 = 1
COS 1 ~ 15 = 0
COS 1 ~ 15 = 0
COS 1 ~ 15 = 0
1800