3.5.3.9

CALCulate2:TRANsform:METEr subsystem

3.5.3.9.1

CALCulate2:TRANsform:METEr:RANGe:AUTO command/query

This sets and reads out ON/OFF of auto range in the analog meter display.
When auto range is ON, the display range is full scale of the measuring range.
Command syntax
:CALCulate2:TRANsform:METEr:RANGe:AUTO <off_on>
<off_on>
<Character program data>
OFF
ON
For ON, AUTO; for OFF, MANUAL
Query syntax
:CALCulate2:TRANsform:METEr:RANGe:AUTO?
Response message <off_on>
<off_on> is <NR1 numeral response data> format.
0 and 1 denote OFF and ON respectively.
ON if the range is set to AUTO, OFF for others.
Remarks
This command/ query is used to make compatibility with version 2.xx or before of the firmware.
For version 3.xx or later, use of ":CALCulate2:TRANsform:METEr:RANGe:MODE[?]" command/
query which supports AUTO mode and LOG mode is recommended (refer to "3.5.3.9.2
CALCulate2:TRANsform:METEr:RANGe:MODE command/query".)
<Numerical program data>
0
1 (Excluding 0)
85