3.7.6 Other commands

The following describes the other commands than MAIN-related, SUB-related, and measurement
function-related commands.
Syntax
:SMPL
Sampling related
:MOD[?]
Setting/reading of sampling method
:ITVL[?]
Setting/reading of interval time
:RATE[?]
Setting/reading of sampling rate
:POW
Power management related
:SET[?]
Setting/reading of setup status at
powered ON
:SLE[?]
Setting/reading of time until power
saving mode
:SIMM
Immediate transition to power saving
mode
:SAVE
Data store related
:STAT[?]
Setting/reading of data store
ON/OFF
:STAR[?]
Setting/reading of saving start
address
:NUMB[?]
Setting/reading of saved data counts
:AINI[?]
Setting/reading of ON/OFF to
initialize storage address
:TINI[?]
Setting/reading of ON/OFF to
initialize time stamp
:CLR
Initialization of all saved data
:RCLL
Data recall related
:RADR[?]
Setting/reading of reading address of
saved data
:DATA?
Reading of saved data at specified
address
:TIME
Time stamp related
:NOW?
Reading of eapsed time after system
start or time stamp initilization
:INIT
Initialization of time stamp
:COMP
Limit calculation related
:SRC[?]
Setting/reading of calculation target
:LVL[?]
Setting/reading of calculation level
:BEEP
Beep related
:KEY[?]
Setting/reading of beep tone
ON/OFF when key is pressed
:ERR[?]
Setting/reading of beep tone when
acquiring error data
:PEAK[?]
Setting/readingof beep tone when
statistic calculation updates
MIN/MAX
:COMP[?]
Setting/reading of beep tone
condiiton according to limit
calculation result
Functions
FREE|HOLD
<Numerical program
data>
SLOW|MID|FAST
LAST|INI
RECALL only for query
<Numerical program
data>
|OFF
OFF|ON or 0|1
<Numerical program
data>
<Numerical program
data>
OFF|ON or 0|1
OFF|ON or 0|1
<Numerical program
data>
<Numerical program
data>
000d00h00m00.00s
(Elapsed day d hour h
minute m second s)
MAIN|SUB|OR|AND
RED|YEL
OFF|ON or 0|1
OFF|ON or 0|1
OFF|ON or 0|1
NOGO|GO|OFF
Parameters
Response; 0:FREE, 1:HOLD
See section 3.7.4 .
Settable values
0(OFF), 1, 5, 10, 30, 60
Execution error for command
Always 0 for query response
Execution error for command
Recorded data count for query
response
Execution error for command
Always 0 for query response
Execution error for command
Always 0 for query response
Max. value: 99,999
Execution error during data
saving
Always MAIN for query
response
Always RED for query response
Always execution error
213