3.3.3
Service request enable register
The service request enable register masks the status byte register. A message is returned to the RQS
or MSS bit, depending on the result of masking. (Consequently, this register masks the SRQ output of
GP-IB.)
The mask pattern is can be set using the SRE command and read using the SRE? query.
Whether or not the contents of this register are cleared (to 0) as the power is turned on is set using
the PSC command.
This does not directly affect the GP-IB instrument clear message and the CLS command.
Status byte register format
6
7
RQS
ESB
OPS
MSS
AND
AND
X
Not used Not used
5
4
3
0
MAV
QES
AND
AND
X
OR
Operation event status
Standard event status
This reflects the output queue
Questionable event status
Measurement event status
0
This is read by the seial pole.
0
Status byte register
MEV
This is read by STB? Query.
AND
X
Service request enable register
26