3.5.8.11.10
[SENSe]:TEMPerature:TRANsducer:RTD:TYPE command/query
This sets and reads out 2 terminal resistance temperature detectors as TEMP measuring sensor.
Command syntax
[:SENSe]:TEMPerature:TRANsducer:RTD:TYPE <rtd_type>
<rtd_type>
<Character program data>
PT100
JPT100
4 terminal measuring setting is also changed.
If this command is executed during trigger waiting status or measurement, none is done and the
execution error occurs.
Query syntax
[:SENSe]:TEMPerature:TRANsducer:RTD:TYPE?
Response message <rtd_type>
<rtd_type> is <character response data> format.
Remark
[:SENSe]:TEMPerature:TRANsducer:RTD:TYPE command/query is effective only for
VOAC7602. It becomes a command error for VOAC7502.
3.5.8.11.11
[SENSe]:TEMPerature:TRANsducer:FRTD:TYPE command/query
This sets and reads out 4 terminal resistance temperature detectors as TEMP measuring sensor.
Command syntax
[:SENSe]:TEMPerature:TRANsducer:FRTD:TYPE <rtd_type>
<rtd_type>
<Character program data>
PT100
JPT100
2 terminal measuring setting is also changed.
If this command is executed during trigger waiting status or measurement, none is done and the
execution error occurs.
Query syntax
[:SENSe]:TEMPerature:TRANsducer:FRTD:TYPE?
Response message <rtd_type>
<rtd_type> is <character response data> format.
Remark
[:SENSe]:TEMPerature:TRANsducer:FRTD:TYPE command/query is effective only for
VOAC7602. It becomes a command error for VOAC7502.
168