Sense]:Current:ac:null:state Command/Query; Sense]:Current:ac:null:value Command/Query - Iwatsu VOAC760 Manual

Remote control manual
Table of Contents

Advertisement

3.5.8.5.6

[SENSe]:CURRent:AC:NULL:STATe command/query

This sets and reads out ON/OFF of the null measurement of ACI measurement.
Command syntax
[:SENSe]:CURRent:AC:NULL[:STATe] <off_on>
<off_on>
<Character program data>
OFF
ON
If this command is executed during trigger waiting status or measurement, none is done and the
execution error occurs.
Query syntax
[:SENSe]:CURRent:AC:NULL[:STATe]?
Response message <off_on>
<off_on> is <NR1 numerical response data> format.
0 and 1 denote OFF and ON respectively.
3.5.8.5.7

[SENSe]:CURRent:AC:NULL:VALue command/query

This sets and reads out the null value of ACI measurement.
It is used for the null measurement of ACI measurement.
Command syntax
[:SENSe]:CURRent:AC:NULL:VALue {<val_data>|MIN|MAX|DEF}
<val_data>
<Numerical program data>
-999.9999E+12 to +999.9999E+12
-999.999E+12 to +999.999E+12
Numerical value beyond limit is set by rounding up maximum value/minimum value, and becomes
execution error.
This allows unit "A".
If this command is executed during trigger waiting status or measurement, none is done and the
execution error occurs.
Query syntax
[:SENSe]:CURRent:AC:NULL:VALue? [{MIN|MAX}]
Response message <val_data>
<val_data> is <NR3 numerical response data> format.
<Numerical program data>
0
1 (Excluding 0)
Resolution
Default value
0.000001E-12
+0.000000E+0
0.00001E-12
+0.00000E+0
135
Models
VOAC7602
VOAC7502

Advertisement

Table of Contents
loading

This manual is also suitable for:

Voac7502

Table of Contents