Fp2Sh - Panasonic FP-E Programming Manual

Fp series
Table of Contents

Advertisement

1.1.6

FP2SH

Item
Relay
External input
relay
External output
relay
Internal relay
(* Note 1)
Link relay
(* Note 1)
Timer
(* Notes 1 and 2)
Counter
(* Notes 1 and 2)
Pulse relay
Error alarm relay
Special
internal relay
Memory
External input
area
relay
External output
relay
Internal relay
Link relay
Data register
(* Note 1)
Link data register
(* Note 1)
Timer/Counter
set value area
(* Note 1)
Timer/Counter
elapsed value area
(* Note 1)
File register
(* Note 1)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
1.1
Numbering
(X) 8,192 points (X0 to X511F)
(Y) 8,192 points (Y0 to Y511F)
(R) 14.192 points (R0 to R886F)
(L) 10,240 points (L0 to L639F)
(T) 3,072 points
( )
,
p
(T0 to T2999/ C3000 to C3071)
(
( )
(C)
(P) 2,048 points (P0 to P127F)
(E) 2,048 points (E0 to E2047)
(R) 176 points (R9000 to R910F)
(WX) 512 words (WX0 to WX511)
(WY) 512 words (WY0 to WY511)
(WR) 887 words (WR0 to WR886)
(WL) 640 words (WL0 to WL639)
(DT) 10,240 words
(DT0 to DT10239)
(LD) 8,448 words (LD0 to LD8447)
(SV) 3,072 words
(SV0 to SV3071)
(EV) 3,072 words
(EV0 to EV3071)
(FL) 98,295 words
,
(32,765 words ×3 banks )
Table of Relays, Memory Areas and Constants
Function
Turn on or off based on external input.
Externally outputs on or off state.
Relay which turns on or off only within pro-
gram.
This relay is a shared relay used for
MEWNET link system.
If a TM instruction has timed out, the con
If a TM instruction has timed out, the con-
tact with the same number turns on.
)
If a CT instruction has counted up, the con-
If a CT instruction has counted up, the con
tact with the same number turns on
This relay is used to turn on only for one
scan duration programmed with the OT
and OT
#
instructions.
If turned on while the unit is running, this
relay stores the history in a dedicated buff-
er.
Program this relay so that it is turned on at
the time of abnormality.
Relay which turns on or off based on spe-
cific conditions and is used as a flag.
Code for specifying 16 external input points
as one word (16 bits) of data.
Code for specifying 16 external output
points as one word (16 bits) of data.
Code for specifying 16 internal relay points
as one word (16 bits) of data.
Code for specifying 16 link relay points as
one word (16 bits) of data.
Data memory used in program. Data is
handled in 16-bit units (one word).
This is a shared data memory which is
used within the MEWNET link system.
Data is handled in 16-bit units (one word).
Data memory for storing a target value of a
timer and an initial value of a counter.
Stores by timer/counter number.
Data memory for storing the elapsed value
during operation of a timer/counter. Stores
by timer/ counter number.
Data memory used in program. Data is
y
handled in 16-bit units (one word).
h
dl d i 16 bit
"
p g
it (
d)
1 - 17