Fp2 - Panasonic FP-E Programming Manual

Fp series
Table of Contents

Advertisement

1.1.5

FP2

Item
Relay
External input
relay
External
output relay
Internal relay
(* Note 1)
Link relay
(* Note 1)
Timer
(* Notes 1 and 2)
Counter
(* Notes 1 and 2)
Pulse relay
Special internal
relay
Memory
External input
area
relay
External
output relay
Internal relay
Link relay
Data register
(* Note 1)
Link data register
(* Note 1)
Timer/Counter
set value area
(* Note 1)
Timer/Counter
elapsed value area
(* Note 1)
File register
(* Notes 1 and 3)
Special data
register
Index register
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
1.1
Numbering
(X) 2,048 points
(X0 to X127F)
(Y) 2,048 points
(Y0 to Y127F)
(R) 4,048 points
(R0 to R252F)
(L) 2,048 points
(L0 to L127F)
(T) 1,024 points
,
p
(T0 to T999/ C1000 to C1023)
(T0 t T999/ C1000 t C1023)
(C)
(P) 1,024 points
(P0 to P63F)
(R) 176 points
(R9000 to R910F)
(WX) 128 words
(WX0 to WX127)
(WY) 128 words
(WY0 to WY127)
(WR) 253 words
(WR0 to WR252)
(WL) 128 words
(WL0 to WL127)
(DT) 6,000 words
(DT0 to DT5999)
(LD) 256 words
(LD0 to LD255)
(SV) 1,024 words
(SV0 to SV1023)
(EV) 1,024 words
(EV0 to EV1023)
(FL) FP2 (16 K):
0 to 14,333 words
(FL0 to FL14332)
FP2 (32 K)
(when expanded):
0 to 30,717 words
(FL0 to FL30716)
(DT) 256 words
(DT90000 to DT90255)
(I) 14 words (I0 to ID)
Table of Relays, Memory Areas and Constants
Function
Turn on or off based on external input.
Externally outputs on or off state.
Relay which turns on or off only within pro-
gram.
This relay is a shared relay used for
MEWNET link system.
If a TM instruction has timed out, the con-
tact with the same number turns on.
t
t ith th
If a CT instruction has counted up, the con-
tact with the same number turns on.
t
t ith th
This relay is used to turn on only for one
scan duration programmed with the OT"
and OT# instructions.
Relay which turns on or off based on spe-
cific conditions and is used as a flag.
Code for specifying 16 external input points
as one word (16 bits) of data.
Code for specifying 16 external output
points as one word (16 bits) of data.
Code for specifying 16 internal relay points
as one word (16 bits) of data.
Code for specifying 16 link relay points as
one word (16 bits) of data.
Data memory used in program. Data is
handled in 16-bit units (one word).
This is a shared data memory which is
used within the MEWNET link system.
Data is handled in 16-bit units (one word).
Data memory for storing a target value of a
timer and an initial value of a counter.
Stores by timer/counter number.
Data memory for storing the elapsed value
during operation of a timer/counter. Stores
by timer/ counter number.
Data memory used in program. Data is
handled in 16-bit units (one word).
Data memory for storing specific data.
Various settings and error codes are
stored.
Register can be used as an address of
memory area and constants modifier.
,
b
t
p,
b
t
1 - 15