3
In the <Attachment Setting Mode> group, select
whether to enable cross-point button operations when
a macro attachment is set.
With Btn Function: Enable cross-point button
operations.
W/o Btn Function: Disable cross-point button
operations.
4
In the <Macro 2nd Recall Mode> group, set the action
to occur during macro execution or when a macro is
paused if the cross-point button that sets the macro
attachment set is double-pressed.
Continue: Execution of a macro that has been paused
is resumed, and an executing macro continues.
Cancel: A paused macro or a macro during execution
is terminated.
5
In the <Macro Recall Override> group, set the action
to occur during macro execution or when a macro is
paused if another macro is recalled.
Disable: Ignore the other macro recall.
Enable: Execute the other macro.
To set a cross-point button with a macro
attachment lit continuously
Press [Attchd Btn Indication], turning it on.
When the [MACRO ATTACH ENABLE] button in the
cross-point Flexi Pad is on and lit orange, cross-point
buttons with a macro attachment are always lit green.
Setting Button and Indicator Status
on the Cross-point Control Block/
AUX Bus Control Block
Setting the color of cross-point buttons
This sets the color when background A bus and B bus
cross-point buttons are lit.
1
In the Engineering Setup >Panel >Operation menu
(7326), press [Xpt Module Operation].
The Xpt Module Operation menu (7326.12) appears.
2
In the <Bank Select> group, select the target bank to
set.
3
In the <A/B Bus Button Color> group, select one of
the following.
Source Color: Lit using the color set in the
Engineering Setup >Panel >Xpt Assign >Src
Name/Src Color menu (7322.6).
White: Lit white.
Setting cross-point indicators
You can disable the cross-point indicators so that they do
not turn on.
1
In the Engineering Setup >Panel >Operation menu
(7326), press [Xpt Module Operation].
The Xpt Module Operation menu (7326.12) appears.
2
In the <Bank Select> group, select the target bank to
set.
3
Press [Xpt Indicator], turning it off.
To enable the cross-point indicators so that they do
turn on, press [Xpt Indicator] again, turning it on.
Configuring the Cross-Point Flexi
Pad
Assigning a function to a cross-point Flexi
Pad button
1
In the <Xpt Flexi Pad> group of the Engineering Setup
>Panel >Operation >Xpt Module Operation menu
(7326.12), press [Flexi Pad Btn Assign].
The Flexi Pad Btn Assign menu (7326.14) appears.
The left side of the status area shows the currently
display page number and buttons, and the right side of
the status area shows a list of assignable functions.
2
In the <Bank Select> group, select the target bank to
set.
3
Select the target page to set.
No.
Parameter Adjustment
1
Page
4
Press the target button to make an assignment.
5
In the list on the right, select the function to assign.
6
Press [Set].
To release the assignment
Select the target button to release, then press [Clear].
To return the assignment to the default
Press [Default Recall], check the message, then press
[Yes].
To rename a page
1
Select the target page number to set, and press [Name].
430