DME Setup
About DME setup
Configure DME1 and DME2.
When the signal format is 1080P, up to four DMEs can be
connected, so configure DME1 to DME4.
This section describes settings for DME1 as an example.
Chapter
Settings Relating to
Signal Inputs
Setting Initial Crop
1
In the <Aspect> group of the Engineering Setup
>DME >Input menu (7341), select the screen aspect
ratio (16:9 or 4:3).
2
In the DME1 <Crop> group, press [Initial Crop] and
set the following parameters.
No.
Parameter Adjustment
1
Top
2
Left
3
Right
4
Bottom
To return the settings to the defaults
In the <Crop> group, press [Unity].
Setting the Illegal Color Limiter for
Matte Signals
Enable/disable the illegal color limiter for the signal
generated by the DME internal matte generator.
To enable, in the Engineering Setup >DME >Input menu
(7341) press [Matte Illeg Col Limit] for DME1, turning it
on.
Adjusting DME System Phase
This adjusts the DME reference phase.
1
In the Engineering Setup >DME >Input menu (7341),
press [System Phase].
457
21
Position of top side
Position of left side
Position of right side
Position of bottom side