Setting Switcher Gpi Outputs; Setting Aux Bus Control - Sony MVS-8000X User Manual

Multi format switcher system with icp-x7000 integrated control panel.
Hide thumbs Also See for MVS-8000X:
Table of Contents

Advertisement

• When the action is "Bkgd A Side Flags" or "Bkgd B
Side Flags," the levels are fixed, as follows.
High level: Off
Low level: On
To set the level for the format converter
1
Select the "Format" action in step 5 in "Setting
Switcher GPI Inputs" (page 452).
The format converter list appears.
2
Select the target format converter to set.
3
Refer to step 2 in "Configuring level settings"
(page 453) and select a setting (signal format).
4
In the <FC Input/Output> group, press [H Set] or [L
Set].

Setting Switcher GPI Outputs

1
In the Engineering Setup >Switcher >Device Interface
menu (7337), press [GPI Output].
The GPI Output menu (7337.4) appears.
2
Select the target to set.
No.
Parameter Adjustment
1
Port
Port selection
3
In the <Trigger Type> group, select the trigger
polarity.
(Rising Edge): Trigger causes the relay to open
or the output to go high level, and holds this state
for the pulse width duration.
(Falling Edge): Trigger causes the relay to
close or the output to go low level, and holds this
state for the pulse width duration.
(Any Edge): When a trigger occurs, the relay
opens/closes or the output goes high/low level,
switching state.
Status: The relay opens/closes or the output goes
high/low level in response to the status.
No Operation: The trigger has no effect on the relay
state or the output level.
4
Set the pulse width and timing.
No.
Parameter Adjustment
3
Pulse
Pulse width
Width
4
Timing
Output timing
5
6
7
Trigger type and actions list
• When the trigger type is other than "Status"
• When the trigger type is "Status"
1) M/E-x: where x is the M/E number (1 to 5)
Testing trigger output
In the Engineering Setup >Switcher >Device Interface
>GPI Output menu (7337.4), press [Test Fire].
This outputs a trigger from the selected output port.
Note
This is no output when the trigger type is "Status."

Setting AUX Bus Control

a)
1
454
a) 1: Field 1, 2: Field 2, 3: Any
Note
When "Any Edge" is selected as the trigger type, only
the [Timing] parameter is available. When "Status" is
selected as the trigger type, there are no parameter
settings.
In the <Source> group, select the source bank to set.
M/E-1 to M/E-5, P/P: Set the actions relating to each
bank.
Common: Set an action relating to error status.
Select the action to set.
No.
Parameter Adjustment
2
Action
Action selection
5
Reg No
Register number
Press [Action Set].
When Source is M/E-x: Cut, Auto Trans, Keyx Cut,
Keyx Auto Trans, Keyx SS ? Recall, Effect ? Recall,
Effect ? Recall & Run, KF Run, KF Stop, KF Rewind,
No Action
When Source is P/P: Cut, Auto Trans, DSKx Cut, DSKx
Auto Trans, FTB Cut, FTB Auto Trans, DSKx SS ?
Recall, Effect ? Recall, Effect ? Recall & Run, KF Run,
KF Stop, KF Rewind, No Action
When Source is Common: No Action
When Source is M/E-x: Keyx On, No Action
When Source is P/P: DSKx On, No Action
When Source is Common: Error Make, Error Break, No
Action
Keyx: where x is the key number (1 to 8)
DSKx: where x is the DSK number (1 to 8)
In the Engineering Setup >Switcher >Device Interface
menu (7337), press [Aux Control].
1)