Chapter 20 Switcher Setup; Switcher Configuration; Adjusting The Reference Phase; Specifying The Video Switching Timing - Sony MVS-8000X User Manual

Multi format switcher system with icp-x7000 integrated control panel.
Hide thumbs Also See for MVS-8000X:
Table of Contents

Advertisement

Switcher Setup

Switcher Configuration

Adjusting the Reference Phase

This adjusts the switcher internal reference phase.
In the Engineering Setup >Switcher >Config menu (7331),
set the following parameter.
No.
Parameter Adjustment
3
Phase
Switcher internal reference phase
Specifying the Video Switching
Timing
1
In the Engineering Setup >Switcher >Config menu
(7331), press [Switching Timing].
The Switching Timing menu (7331.8) appears.
2
Select one of the following.
Any: Not specified
Field 1: Field 1
Field 2: Field 2
Note
When the signal format is 720P, 1080PsF, or 1080P, the
switching timing cannot be specified.

Setting the Operation Mode

This sets the output signal configuration for each bank.
In the <M/E Config> group of the Engineering Setup
>Switcher >Config menu (7331), select the operation
mode for each M/E or PGM/PST bank.
Standard: Standard mode
Multi Program: Multi-program mode
DSK: DSK mode (PGM/PST only)
Chapter
About the operation mode
• Standard mode: Fix the output signal configuration for
the maximum of four outputs (Out1 to 4) of the M/E and
PGM/PST banks as follows.
- Out1: Program output
- Out2: Preview output
- Out3: Clean output
- Out4: Key preview output
• Multi-program mode: Increase the number of M/E or
PGM/PST program systems, and assign one of the
following to up to six outputs (Out1 to 6) (M/E Output
Assign).
- Program outputs 1 to 4
- Preview output
- Key preview outputs
- Clean output
Further, you can change the combination of signals
from which the program output is configured (PGM
Config).
• DSK mode: Treats PGM/PSTs as DSKs by assigning
one of the Out1 to Out6 program outputs of M/E-1 to M/
E-5 to the background. You can change the signals that
make up the output signal selection (M/E Output
Assign), program output, and key preview output
using PGM Config and K-PVW Config.
1) For the key preview output, you can select either video mode (background
and key) or key mode (key only), and select the background and key (K-
PVW Config).
Note
When Multi-program mode is selected, two or more
transition type selection buttons may be lit on the transition
control block. Also, more than one <Transition Type>
group button may be selected in the Misc >Transition
menu of each M/E and PGM/PST bank.
Assigning the output of each bank in
multi-program mode
This configures settings when [Multi Program] is selected
as the operation mode.
1
In the Engineering Setup >Switcher >Config menu
(7331), press [M/E Output Assign].
434
20
1)
1)
1 and 2
1)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents