The M/E Operation Inhibit menu (7321.18) appears.
3
Select the target bank to set.
4
In the <M/E Operation Inhibit> group, select the utility
2 bus (Util2 Bus) or key button (Key1 to Key8) for
which operations are to be inhibited.

Inhibiting DME Channel Selection

Operations

You can inhibit DME channel selection operations in the
device control block (trackball).
1
In the Engineering Setup >Panel >Config menu
(7321), press [Operation Inhibit].
The Operation Inhibit menu (7321.26) appears.
2
Press [Trackball Module].
The Trackball Module menu (7321.27) appears.
3
Select the DME channel for which to inhibit operation.
4
Press [Inhibit].

Cross-Point Settings

Creating Cross-Point Assign Tables

You can create a "main" table and up to 14 other tables
(table 1 to table 14) as cross-point assign tables. However,
you can only carry out assignment of video and key
combinations in the main table.
Creating the main table
In the main table, a pair consisting of a video signal and a
key signal is assigned to each button number. You can also
assign the same signal to another button number to
duplicate the assignment. You can also delete currently
assigned signals.
1
In the Engineering Setup >Panel >Xpt Assign menu
(7322) or the Engineering Setup >Panel >Xpt Assign
>Table Button Assign menu (7322.1), press [Main, V/
K Pair Assign].
The Main, V/K Pair Assign menu (7322.5) appears.
The left side of the status area shows the video and key
signal names currently assigned in the main table, and
the source numbers. When the shift button is pressed,
the number field is distinguished by color.
The right side of the status area shows a list of source
numbers and assignable signals.
2
Select the target button number to set.
No.
Parameter Adjustment
1
V/K Pair No Selection of video and key pair
3
In the <Assign> group, select the target signal to set.
Video: Set video signals.
Key: Set key signals.
[Video] and [Key] can also be selected at the same
time.
[Video] and [Key] cannot be deselected at the same
time. One or the other is always selected.
4
Select the signal to assign.
No.
Parameter Adjustment
3
Source No
5
In the <Xpt Assign> group, select one of the
following.
413
number
Selection of signal to assign