Selecting the Primary Input to use as
the Format Converter
On the MVS-7000X, the primary input used by the format
converter must be specified.
1
In the Engineering Setup >Switcher >Input menu
(7332), press [FC Input Select].
The FC Input Select menu (7332.3) appears.
The status area shows the format converter list on the
left and the primary input number list on the right.
2
In the list on the left, select the FC (format converter)
number.
3
In the list on the right, select the primary input number.
4
Press [Set].
5
To enter the name of the input signal converted in the
format converter, press [FC Name].
6
Enter a name of up to 16 characters in the keyboard
window, and press [Enter].

Setting the Frame Delay Function

1
In the Engineering Setup >Switcher >Input menu
(7332), select the target input signal to set.
You can select input signals for which the frame delay
function is enabled in advance.
2
Set the following parameter.
No.
Parameter Adjustment
Delay (1 to 8 frames)
2
Frame
Delay
a) When the signal format is 720P or 1080P, the delay (number of
frames) is twice the set adjustment value.
Selecting the Format Converter
Conversion Method
This sets the input used for the format converter and the
conversion method.
Note
The setup menu display varies if IP converter or 4K up-
converter is selected.
For details about the IP converter, see "Setting the IP
Converter Conversion Method" (page 441).
For details about the 4K up-converter, see "Setting the 4K
Up-Converter Conversion Method" (page 442).
Selecting the target inputs to set
The same settings are applied to each of four groups: FC1
to FC4, FC5 to FC8, FC9 to FC12, and FC13 to FC16.
Notes
• FC9 to FC12 and FC13 to FC16 can be used only on the
MVS-8000X.
• For the cross-converter, conversion method settings are
not required.
1
In the Engineering Setup >Switcher >Input menu
(7332), press [FC Adjust].
The FC Adjust menu (7332.2) appears.
a) These buttons do not appear when the frame delay
a)
function is set.
2
Press [FC Input 1-4], [FC Input 5-8], [FC Input 9-12],
or [FC Input 13-16] to select the group.
3
Select the target to set.
Setting the up-converter conversion
method
1
In the Engineering Setup >Switcher >Input >FC
Adjust menu (7332.2), select the target input to set.
2
In the <Conversion> group, select one of the
following.
Frame: Conversion in frame units
439