2
Set the following parameters.
No.
Parameter Adjustment
1
DME1
DME1 system phase adjustment
Phase
2
DME2
DME2 system phase adjustment
Phase
Note
When the signal format is 1080P, you can configure
DME3 and DME4 using the [DME3 Phase] and
[DME4 Phase] parameters.
Setting the TBC Window Center
Position
1
In the Engineering Setup >DME >Input menu (7341),
press [TBC Center].
The TBC Center menu (7341.1) appears.
The status area shows the TBC center positions for
external input signals on each DME.
Note
The TBC center position values for external input
signals are shown only when an MVE-9000 or MKS-
7470X/7471X is used.
2
Select the target input number to set.
3
In the <Video/Key> group or <External Video> group,
set the TBC center position (0H, 0.5H, or 1H).
The settings in the <Video/Key> group are valid only
when using an MVE-8000A/9000 SDI interface.
The settings in the <External Video> group are valid
only when using an MVE-9000 or MKS-7470X/
7471X.
Settings Relating to
Signal Outputs
Adjusting the DME Output Video
Clip Level
When the MVE-8000A/MVE-9000 is used with an SDI
interface, you can adjust the DME output video clip levels.
1
In the <DME1 (Ch1-Ch4)> group of the Engineering
Setup >DME >Output menu (7343), press [Clip
Adjust].
2
Set the following parameters.
No.
Parameter Adjustment
1
White Clip
2
Dark Clip
3
Chroma
Clip
To return the settings to the defaults
In the <DME1 (Ch1-Ch4)> group, press [Default].
Setting the Monitor Output
You can select the signals output from the four monitor
output systems.
1
In the Engineering Setup >DME >Output menu
(7343), press [Monitor Output].
The Monitor Output menu (7343.1) appears.
2
In the <Select> group, select the target DME to set.
3
In the list on the left of the status area, select the target
monitor to set.
Note
On the MVE-8000A, when the signal format is 1080P,
Moni Out#2 and Moni Out#4 cannot be selected.
4
In the list on the right of the status area, select the
signal you want to output.
5
Press [Set].
458
White clip
Dark clip
Chroma clip