Control Panel - Sony MVS-8000X User Manual

Multi format switcher system with icp-x7000 integrated control panel.
Hide thumbs Also See for MVS-8000X:
Table of Contents

Advertisement

For SDTV, connect a black burst signal or analog sync
signal.
The two connectors are link through, so that the signal
input on either connector is also output on the other
connector. Connect the supplied 75 terminator to the
remaining connector if not using the link through output.
d UTIL (utility) connector (RJ-45, 1000BASE-T
compliant)
Reserved for future use.
e MVS (multi format video switcher) connector (RJ-
45, 1000BASE-T compliant)
Connect to a MVS-8000X/7000X multi format switcher
processor and ICP-X7000 integrated control panel via an
Ethernet switch.
f S-BUS connector (BNC-type)
Connect a cable with BNC connector to an S-Bus data link
via a T bridge.
Connecting devices such as routing switchers and AUX
bus remote panels via an S-Bus data link enables the
following kinds of control.
• Generation and return of tally information on the S-Bus,
based on data received from other devices.
• Switching of cross-points on a routing switcher from the

control panel.

• Switching of cross-points on a switcher from the remote
panel.
• Display of source names configured by a routing
switcher on the control panel.
g REMOTE 1 to 6 connectors or 1 to 4 connectors (D-
sub 9-pin, RS-422A)
Connect to a device controlled using Sony 9-pin VTR,
VDCP (Video Disk Communications Protocol), Odetics
protocol, or P-Bus (Peripheral II Protocol) protocols.
h SERIAL TALLY 1 and 2 connectors (D-sub 9-pin,
RS-422A compliant)
Outputs tally information generated by the control panel of
the MVS system.
i TALLY/GPI OUT 1 to 54 connectors or 1 to 36
connectors (D-sub 25-pin)
Outputs tally information generated by the control panel of
the MVS system using a relay. It can also be used as a GPI
output port.
The output setting is controlled from the control panel of
the MVS system.
j TALLY/GPI IN 1 to 68 connectors or 1 to 34
connectors (D-sub 25-pin)
Input a trigger signal as a GPI input.
The input setting is controlled from the control panel of the
MVS system.