2
Select the target button to set.
3
Select the transition rate to assign.
4
Press [Set].
To release the assignment
Select the target button to release, then press [Clear].
Assigning Functions to 1st Row/2nd
Row Buttons of the Cross-Point
Control Block
You can assign functions to the 1st row/2nd row buttons of
the cross-point control block (utility/shotbox mode).
1
In the Engineering Setup >Panel >Prefs/Utility menu
(7324), press [Xpt Module Assign].
The Xpt Module Assign menu (7324.2) appears.
2
Select the target button to set.
No.
Parameter Adjustment
1
Bank
Bank selection
2
Button No
Button selection
3
In the <Action> group, select the function to assign.
Menu Shortcut: Assign a frequently used menu to be
recalled (menu shortcut).
Utility Command: Assign a function setting (utility
command).
Macro Recall: Assign a macro register recall.
Shotbox Recall: Assign a shotbox register recall.
4
Perform the following operations, according to the
selection in step 3.
When [Menu Shortcut] is selected: When the 1st
row/2nd row button on the cross-point control
block is blinking, display the shortcut menu. Press
the target button to set to assign a shortcut. When
finished, press [Menu Shortcut] again.
When [Utility Command] is selected: Select a
command to assign in the list on the right side of
the status area.
No.
Parameter Adjustment
3
Command
Utility command selection
GPI No
GPI number
a)
4
a) SWR GPI Test Fire and DCU GPI Test Fire commands only
When [Macro Recall] is selected: Select the macro
register to assign.
No.
Parameter Adjustment
3
Macro
When [Shotbox Recall] is selected: Select the
shotbox register to assign.
No.
Parameter Adjustment
3
Shotbox
5
Press [Action Set].
When [Menu Shortcut] is selected in step 3, it is not
necessary to press [Action Set].
To release the assignment
Select the target button to release, then press [Clear].
To display register names in the Utility Command
field
When [Macro Recall] or [Shotbox Recall] is selected in
step 3, you can select whether to display register names in
the Utility Command field.
To enable display, press [Reg Name Display], turning it
on.
For details about utility commands that can be assigned to
the 1st row/2nd row buttons, see "List of utility commands
and user preference button states" (page 419).
Settings names to show on the display
You can set the display of names on the display when
menu shortcuts or utility commands are assigned to the 1st
row/2nd row buttons.
Note
When a macro register is assigned, the names specified in
the Macro menu are displayed on the display. When a
shotbox register is assigned, the names specified in the
Shotbox menu are displayed on the display.
1
In the Engineering Setup >Panel >Prefs/Utility >Xpt
Module Assign menu (7324.2), select the target button
to set.
2
Press [Name].
3
Enter a name of up to 8 characters in the keyboard
window, and press [Enter].