The Aux Control menu (7337.5) appears.
2
In the <Control> group, select the target 9-pin port to
set.
Remote1: Make settings for the REMOTE1 port.
Remote2: Make settings for the REMOTE2 port.
Remote3: Make settings for the REMOTE3 port.
Remote4: Make settings for the REMOTE4 port.
3
Select the AUX bus.
4
In the <Control Mode> group, select one of the
following.
Enable: Enable control of the port selected in step 2.
Disable: Disable control of the port selected in step 2.
Manual: Set whether control of the port selected in
step 2 is enabled according to the setting in the
Misc menu.
5
Repeat steps 2 to 4 as required to set other ports.
Setting the Interface Between the
DME and the Switcher
1
In the Engineering Setup >Switcher >Device Interface
menu (7337), press [DME Type Setting].
The DME Type Setting menu (7337.6) appears.
2
In the <DME1 Type> group and <DME2 Type>
group, set DME1 and DME2 to one of the following.
Dedicated: The DME is connected via a dedicated
interface.
SDI: The DME is connected via an SDI interface.
Note
If the system signal format is set to 1080P and the
DME input/output signal format is set to Dual Link
Mode, the SDI interface cannot be selected.
For details about the connection of DME units and the
switcher, refer to the MVS-8000X-C/7000X-C
Installation Manual.
3
In the <DME Assignment for Proc Key> group, select
one of the following.
Single DME unit: Mode in which a processed key
operation is executed with a dedicated interface
DME only or an SDI interface DME only.
Dual DME units: Mode in which two processed key
operations, one each using a dedicated interface
DME and an SDI interface DME, can be executed
simultaneously on the same M/E. When this mode
is selected and a signal is combined with a
processed key that uses an SDI interface DME,
select the material for the second channel not on
the DME external video bus, but on the AUX bus.
Setting AUX Bus Outputs and Re-
entry Inputs
This sets the signal input to the DME (AUX bus output)
and the signal returned as the switcher primary input (re-
entry input).
1
In the Engineering Setup >Switcher >Device Interface
>DME Type Setting menu (7337.6), press [DME SDI
Interface].
The DME SDI Interface menu (7337.7) appears.
2
Select the target DME channel to set.
Note
When using the MVE-8000A, it is not possible to
select DME 1 Ext In to DME 8 Ext In.
3
In the <Select> group, select the AUX bus or re-entry
to assign to the DME channel.
Aux Bus: Set the AUX bus.
Re-Entry: Set re-entry.
4
Depending on the selection in step 3, set the following
parameters.
When [Aux Bus] is selected
No.
Parameter Adjustment
2
Src No
When [Re-Entry] is selected
No.
Parameter Adjustment
2
Src No
5
Press [Set].
6
Repeat steps 2 to 5 as required.
Setting the Key Off Mode for Control
from an Editor
This selects the mode for turning off keys when the "All
Stop" command is received from an editor.
1
In the Engineering Setup >Switcher >Device Interface
menu (7337), press [Editor I/F].
455
AUX bus number
Re-entry number

Hide quick links: