Parallel Tally Settings

Configure the parallel port on which to output tally
information for each source and destination. For each tally
output terminal number, specify the tally type, and source
address or destination level and address.

Configuring/Modifying Parallel Tally

1
In the <Device> group of the Engineering Setup
>Router/Tally >Parallel Tally menu (7366), select one
of the following.
DCU1: Set the SIU1 (DCU function) parallel tally.
DCU2: Set the SIU2 (DCU function) parallel tally.
2
Select the slot number and port number.
No.
Parameter Adjustment
1
Slot No
Parallel tally slot number
2
Port No
Parallel tally port number
Note
On the MKS-X2700, select 2 for the slot and a value in
the range 1 to 36 for the port.
3
Press [Set].
The Set menu (7366.1) appears.
4
In the <Source/Destination> group, select the tally
type.
Src: Return a tally to all sources that are output to the
destination.
Dest: Return a tally to destinations outputting sources
that return a tally using source tally.
5
Set the destination address and level.
The level setting is only required when [Dest] is
selected in step 4.
No.
Parameter Adjustment
1
Address
Destination address
2
Level
Destination level
6
To set the tally type, set the following parameter.
No.
Parameter Adjustment
3
Type
a) 1: R1, 2: G1, 3: R2, 4: G2, 5: R3, 6: G3, 7: R4, 8: G4, 9: R5, 10: G5,
11: R6, 12: G6, 13: R7, 14: G7, 15: R8, 16: G8 (R stands for Red
Tally, and G for Green Tally)
7
Press [Execute].

Deleting Parallel Tally

1
In the Engineering Setup >Router/Tally >Parallel
Tally menu (7366), select the parallel tally.
2
Press [Clear].
475