Installing the Base Station
Figure 4‐28: Basic use of lightning protectors
To install a LPU on a pole adjacent to an ODU (HBS or HSU):
1. Mount one LPU on the 
ODU pole, as close as 
possible to the ODU.
2. Ground the LPU to the 
pole using the grounding 
lug.
3. Connect the 0.5 meter 
CAT‐5e cable to the IDU 
port of the ODU.
4. Connect the other end of 
the cable to the top of 
the LPU.
5. Tighten the top cable LPU 
gland cap.
6. Connect the main ODU‐
IDU cable from the IDU to the bottom end of the LPU.
7. Tighten the bottom cable LPU gland cap.
8. Run the main ODU‐IDU cable towards the IDU location.
9. Insulate both LPU connections. See the next section, Additional Considerations for 
Waterproofing
RADWIN 5000 HPMP User Manual