Private MIB Parameters
Table C‐2: Private MIB Parameters ‐ HBS (Sheet 24 of 33)
Name
winlink1000IduTdmLoopbackConfig
winlink1000IduTdmLineStatus
winlink1000IduTdmCurrentTable
winlink1000IduTdmCurrentEntry
winlink1000IduTdmCurrentIndex
winlink1000IduTdmCurrentBlocks
winlink1000IduTdmCurrentDrops
winlink1000IduTdmCurrentTxClock
winlink1000IduTdmCurrentBlocksHi
gh
winlink1000IduTdmRemoteQual
winlink1000IduTdmRemoteQualEva
l
winlink1000IduTdmSrvEval
winlink1000IduTdmBackupAvailabl
eLinks
winlink1000IduTdmBackupTable
winlink1000IduTdmBackupEntry
winlink1000IduTdmBackupIndex
winlink1000IduTdmBackupMode
winlink1000IduTdmBackupCurrentA
ctiveLink
winlink1000IduTdmJitterBufferSize
winlink1000IduTdmJitterBufferDefa
ultSize
winlink1000IduTdmJitterBufferMinS
ize
winlink1000IduTdmJitterBufferMax
Size
winlink1000IduTdmJitterBufferSizeE
val
RADWIN 5000 HPMP User Manual
OID
Type
Release 3.5.70
Description
RW Loop back configuration table. Each of the
trunks can be set Normal Line loop back or
Reverse line loop back. A change is effective
immediately.
RO
Line status.
N/A IDU TDM Links Statistics table.
N/A IDU TDM Links Statistics table entry. INDEX {
winlink1000IduTdmCurrentIndex }
RO
Table index (Same as
winlink1000IduTdmLineIndex).
RO
Number of correct blocks transmitted to the
line.
RO
Number of error blocks transmitted to the line.
RW TDM Transmit Clock. A change is effective after
re‐activation of the TDM service.
RO
High part of the 64 bits counter Current Blocks
RO
Estimated average interval between error
second events. The valid values are 1‐2^31
where a value of ‐1 is used to indicate an
undefined state.
RO
Estimated average interval between error
second events during evaluation process. The
valid values are 1‐2^31 where a value of ‐1 is
used to indicate an undefined state.
RW Evaluated TDM service bit mask. Setting this
parameter to value that is bigger than the
activated TDM service bit mask will execute
the evaluation process for 30 seconds. Setting
this parameter to 0 will stop the evaluation
process immediately.
RO
Number of TDM backup trunks.
N/A IDU TDM Links Statistics table.
N/A IDU TDM Links Statistics table entry. INDEX {
winlink1000IduTdmBackupIndex }
RO
Table index.
RW TDM backup mode: Enable or Disable where
the main link is the air link or the external link.
Changes will be effective immediatly.
RO
TDM backup current active link: N/A air link is
active or external link is active.
RW TDM Jitter Buffer Size. The value must be
between the minimum and the maximum TDM
Jitter Buffer Size. The units are 0.1 x
millisecond.
RO
TDM Jitter Buffer Default Size. The units are 0.1
x millisecond.
RO
TDM Jitter Buffer Minimum Size. The units are
0.1 x millisecond.
RO
TDM Jitter Buffer Maximum Size. The units are
0.1 x millisecond.
RW TDM Jitter Buffer Size for evaluation. The
value must be between the minimum and the
maximum TDM Jitter Buffer Size. The units are
0.1 x millisecond.
C‐29