Private MIB Parameters
Table C‐2: Private MIB Parameters ‐ HBS (Sheet 23 of 33)
Name
winlink1000IduEthernetIfTable
winlink1000IduEthernetIfEntry
winlink1000IduEthernetIfIndex
winlink1000IduEthernetIfAddress
winlink1000IduEthernetNumOfLan
Ports
winlink1000IduEthernetNumOfSfpP
orts
winlink1000IduEthernetSfpProperti
es
winlink1000IduEthernetGbeSuppor
ted
winlink1000IduEthernetOduInError
s
winlink1000IduBridgeTpAging
winlink1000IduTdmTxClockAvailStat
es
winlink1000IduTdmTxClockDesiredS
tate
winlink1000IduTdmTxClockActualSt
ate
winlink1000IduTdmMasterClockAva
ilOptions
winlink1000IduTdmMasterClockDes
ired
winlink1000IduTdmMasterClockAct
ual
winlink1000IduTdmConfigTable
winlink1000IduTdmConfigEntry
winlink1000IduTdmConfigIndex
winlink1000IduTdmIfIndex
winlink1000IduTdmLineCoding
RADWIN 5000 HPMP User Manual
OID
Type
Release 3.5.70
Description
N/A IDU Ethernet Interface table.
N/A IDU Ethernet Interface table entry. INDEX {
winlink1000IduEthernetIfIndex }
RO
If Index corresponding to this Interface.
RO
IDU MAC address.
RO
Number of LAN interfaces in the IDU.
RO
The number of SFP interfaces in the IDU.
RO
SFP venfor properties : Vendor Name PN and
Revision.
RO
Supported Giga bit Ethernet in IDU.
RO
The number of inbound packets that contained
errors preventing them from being deliverable
to a higher‐layer protocol.
RW Timeout in seconds for aging. Note that for this
parameter to be effective the ODU must be
configured to HUB mode. A change is effective
immediately.
RO
Available states of the TDM Transmit Clock
Control each input status is represented by a
bit. When the state is available the bit value is
1. When the state is unavailable the bit value
is 0. The available states are: bit 2 =
Transparent bit 3 = Local Loop Timed bit 4 =
Remote Loop Timed bit 5 = Local Internal bit 6
= Remote Internal
RW Required state of the TDM Transmit Clock
Control. A change is effective after re‐activation
of the TDM service.
RO
Actual state of the TDM Transmit Clock Control.
RO
Available options of the TDM Master Clock
Control each input status is represented by a
bit. When the option is available the bit value
is 1. When the option is unavailable the bit
value is 0. The available options are: bit 2 =
Automatic bit 3 = Trunk #1 bit 4 = Trunk #2 bit
5 = Trunk #3 bit 6 = Trunk #4 When no options
are available the returned value is: 1
RW Required TDM Master Clock. A change is
effective after re‐activation of the TDM service.
RO
Actual Trunk used for TDM Master Clock.
N/A IDU TDM Links Configuration table.
N/A IDU TDM Links Configuration table entry.
INDEX { winlink1000IduTdmConfigIndex }
RO
Table index.
RO
Link index in the interface table.
RW This parameter applies to T1 trunks only. The
parameter controls the line coding. Setting the
value to each of the indices applies to all. A
change is effective after the next open of the
TDM service.