Radwin 5000 HPMP User Manual page 427

5000 series point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Private MIB Parameters
Table C‐2: Private MIB Parameters ‐ HBS (Sheet 3 of 33)
Name
winlink1000OduAdmOvrdCmd
winlink1000OduAdmLinkMode
winlink1000OduAdmActualConnect
Mode
winlink1000OduAdmAES256Suppor
t
winlink1000OduAdmAES256State
winlink1000OduAdmAES256Status
winlink1000OduAdmBatterySavingS
hutdownTime
winlink1000OduAdmWiFiPowerMo
de
winlink1000OduAdmShutdownTim
er
winlink1000OduAdmGPSState
winlink1000OduAdmTemperatureC 1.3.6.1.4.1.4458.1000.1.1.4
winlink1000OduAdmIPStackMode
winlink1000OduAdmIPv6ParamsCnf
g
winlink1000OduAdmIPv6Address
winlink1000OduAdmIPv6Prefix
winlink1000OduAdmIPv6DefaultGa
teWay
winlink1000OduSrvMode
winlink1000OduSrvBridging
winlink1000OduSrvRingLinkMode
winlink1000OduSrvRingTopologySu
pported
winlink1000OduSrvRingVlanIdTable
winlink1000OduSrvRingVlanIdEntry
winlink1000OduSrvRingVlanIdIndex
winlink1000OduSrvRingVlanId
winlink1000OduSrvRingEthStatus
winlink1000OduSrvRingMaxAllowe
dTimeFromLastRpm
RADWIN 5000 HPMP User Manual
OID
Type
1.3.6.1.4.1.4458.1000.1.1.3
DisplayString
4
1.3.6.1.4.1.4458.1000.1.1.3
Integer
5
1.3.6.1.4.1.4458.1000.1.1.3
Integer
6
1.3.6.1.4.1.4458.1000.1.1.3
Integer
7
1.3.6.1.4.1.4458.1000.1.1.3
Integer
8
1.3.6.1.4.1.4458.1000.1.1.3
Integer
9
1.3.6.1.4.1.4458.1000.1.1.4
Integer
0
1.3.6.1.4.1.4458.1000.1.1.4
Integer
1
1.3.6.1.4.1.4458.1000.1.1.4
Integer
2
1.3.6.1.4.1.4458.1000.1.1.4
Integer
3
Integer
4
1.3.6.1.4.1.4458.1000.1.1.4
Integer
5
1.3.6.1.4.1.4458.1000.1.1.4
DisplayString
6
1.3.6.1.4.1.4458.1000.1.1.4
DisplayString
7
1.3.6.1.4.1.4458.1000.1.1.4
Integer
8
1.3.6.1.4.1.4458.1000.1.1.4
DisplayString
9
1.3.6.1.4.1.4458.1000.1.2.1
Integer
1.3.6.1.4.1.4458.1000.1.2.3
Integer
Release 3.5.70
Description
RW Ability to perform special command in the ODU. 
RW Unit PMP operation mode. 
RO
Unit connected as part to ptp or ptmp. 
RO
AES‐256 security support indication. 
RW Enable/Disable AES‐256 security mode over the 
air link. 
RO
AES256 operating status 
RW Battery Saving Shutdown Time in minutes  0 till 
battery run out  ‐1 if not supported. 
RW WIFI unit power mode. 
RO
Shutdown Timer in seconds. 
RO
GPS state 
RO
The temperature (Celsius) inside the Board. 
RW The IP stack mode. 
RW ODU IPv6 address Configuration. The format is: 
<IP_Address>|<Subnet_Mask>|<Default_Gatew
ay>| 
RO
ODU IPv6 address. 
RO
ODU IPv6 subnet mask. 
RO
ODU IPv6 default gateway. 
RW System mode. The only values that can be set 
are installMode and slaveMode;   normalMode 
reserved to the Manager application provided 
with the product.   A change is effective after 
link re‐synchronization. 
RO
Bridging Mode. Valid values are: disabled (0)  
enabled (1). 
RW Mode of the link regarding ring topology. 
RO
Ring Topology  options are: supported  not 
supported 
N/A Ring VLAN IDs table. 
N/A VLAN ID of the internal ring messages. Valid 
values are 1 to 4094.   Initial value is 0 meaning 
VLAN unaware.   INDEX { 
winlink1000OduSrvRingVlanIdIndex } 
RO
Index of VLAN ID of the internal ring messages.    
RW VLAN ID of the internal ring messages. Valid 
values are 1 to 4094.   Initial value is 0 meaning 
VLAN unaware. 
RO
Represents the Ethernet service blocking state 
of a Rings link 
RW Defines the minimal time (in ms) required for 
determination of ring failure. 
C‐8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents