Telnet Access to the HSU
Table 8‐8: HSU Telnet ‐ Set Immediate Commands
Command
set ip <ipaddr> <subnetMask>
<gateway>
set trap <index:1‐10> <ipaddr>
<port:0‐65535>
set readpw <oldpasswd> <passwd>
set writepw <oldpasswd> <passwd>
set trappw <oldpasswd> <passwd>
set buzzer
<mode:0=OFF,1=AUTO,2=ON>
set tpc<power:Value between
minimal Tx power, and maximal Tx
power>
set name <new name>
set location <new location>
set contact <new contact>
set ethernet <port:LAN1>
<mode:AUTO,10H,10F,100H,100F,D
ISABLE>
reboot
help
Table 8‐9: HSU Telnet ‐ Set Commands requiring Reset
Command
set secId <SectorID>
RADWIN 5000 HPMP User Manual
Explanation
Set the ODU IP address, subnet mask and gateway.
The user must reset the ODU after the command
completion
Set a specific trap from the traps table (e.g. set trap 3
192.168..101 162)
Set the read access password (Read Community)
Set the read‐write access password (Read‐Write
Community)
Set the trap Community string
Set the buzzer mode
Set the ODU Tx Power. If a wrong value is entered,
both min and max values shall be displayed in the
error reply
Set the name of the link
Set the name of the location
Set the name of the site manager
Set the mode and speed of the Ethernet port
Resets the ODU. The user is warned that the
command will reset the ODU. A new Telnet session to
the ODU may be opened after the reset is complete.
Displays the available commands
Explanation
Set new sector ID ‐ Reset required.