Installation Procedure
Installation Procedure
For M12 connectors, use a locking torque of 0.49Nm.
Note
Unpacking and Checking
For each of the items below, do the following:
1. Remove the equipment from the box.
2. Check that everything listed on the included Bill of Materials or Pro‐forma Invoice is 
present.
3. If any item is missing, contact Customer Service. You will be advised whether to 
return the package for replacement, or whether the missing item can be supplied 
separately.
4. Do not dispose of the packaging until the unit is installed and operational.
Tools and Additional Materials
Spanner/wrench, screw drivers various (primarily for small electrical connections)
Drill 
Sealing material or other waterproofing tape such as Scotch 23 Tape ¾" wide, from 3M 
to ensure protection against water and dust for cable entry into the vehicle.
Installation
Mount the VMU in a safe protected location. The ambient temperature should be in the 
range ‐35°C to +60°C (‐31°F to +140°F).
To prepare the vehicle for VMU installation:
1. Locate and mark the VMU in the place where you want to mount it.
2. Determine the precise location of the antennas on the roof‐top.
3. Route the cables from the vehicle battery area to the VMU location.
4. Route the cables from the antenna location to the VMU location.
5. Route the cables from the cabin PC/Camera to the VMU location.
To physically mount the VMU: 
1. Place the unit against the surface to which it is to be mounted. 
2. Mark the screw placements using four of the mounting holes in the unit as guides. 
3. Drill holes in the surface using your marks. 