Private MIB Parameters
Table C‐3: Private MIB Parameters ‐ HSU (Sheet 5 of 33)
Name
winlink1000OduEthernetIfFailActio
n
winlink1000OduEthernetNumOfPor
ts
winlink1000OduEthernetGbeSuppo
rted
winlink1000OduBridgeBasePortTabl
e
winlink1000OduBridgeBasePortEntr
y
winlink1000OduBridgeBasePortInd
ex
winlink1000OduBridgeBaseIfIndex
winlink1000OduBridgeTpMode
winlink1000OduBridgeTpPortTable
winlink1000OduBridgeTpPortEntry
winlink1000OduBridgeTpPortIndex
winlink1000OduBridgeTpPortInFra
mes
winlink1000OduBridgeTpPortOutFr
ames
winlink1000OduBridgeTpPortInByte
s
winlink1000OduBridgeTpPortOutBy
tes
winlink1000OduBridgeConfigMode
winlink1000OduAirFreq
winlink1000OduAirDesiredRate
winlink1000OduAirSSID
winlink1000OduAirTxPower
winlink1000OduAirSesState
winlink1000OduAirMstrSlv
winlink1000OduAirResync
RADWIN 5000 HPMP User Manual
OID
Type
1.3.6.1.4.1.4458.1000.1.3.2.
Integer
1.8
1.3.6.1.4.1.4458.1000.1.3.3
Integer
1.3.6.1.4.1.4458.1000.1.3.4
Integer
1.3.6.1.4.1.4458.1000.1.4.4.
Integer
101
1.3.6.1.4.1.4458.1000.1.4.4.
Integer
3.1.1
1.3.6.1.4.1.4458.1000.1.4.4.
Counter
3.1.3
1.3.6.1.4.1.4458.1000.1.4.4.
Counter
3.1.4
1.3.6.1.4.1.4458.1000.1.4.4.
Counter
3.1.101
1.3.6.1.4.1.4458.1000.1.4.4.
Counter
3.1.102
1.3.6.1.4.1.4458.1000.1.4.4.
Integer
102
1.3.6.1.4.1.4458.1000.1.5.1
Integer
1.3.6.1.4.1.4458.1000.1.5.2
Integer
1.3.6.1.4.1.4458.1000.1.5.3
DisplayString
1.3.6.1.4.1.4458.1000.1.5.4
Integer
1.3.6.1.4.1.4458.1000.1.5.5
Integer
1.3.6.1.4.1.4458.1000.1.5.6
Integer
1.3.6.1.4.1.4458.1000.1.5.8
Integer
Release 3.5.70
Description
RW Failure action of the interface.
RO
Number of ODU network interfaces.
Supported Giga bit Ethernet in ODU.
N/A ODU Bridge Ports table.
N/A ODU Bridge Ports table entry. INDEX {
winlink1000OduBridgeBasePortIndex }
RO
ODU Bridge Port Number.
RO
IfIndex corresponding to ODU Bridge port.
RW ODU bridge mode. A change is effective after
reset. Valid values: hubMode (0) bridgeMode
(1).
N/A ODU Transparent Bridge Ports table.
N/A ODU Transparent Bridge Ports table entry.
INDEX { winlink1000OduBridgeTpPortIndex }
RO
ODU Transparent Bridge Port Number.
RO
Number of frames received by this port.
RO
Number of frames transmitted by this port.
RO
Number of bytes received by this port.
RO
Number of bytes transmitted by this port.
RO
ODU bridge configuration mode
RW Installation Center Frequency. Valid values are
product dependent. A change is effective after
link re‐synchronization.
RW Deprecated parameter actual behavior is read‐
only. Required Air Rate. For Channel
Bandwidth of 20 10 5 MHz divide the value by
1 2 4 respectively.
RW Reserved for the Manager application provided
with the product. The Sector ID in Point‐To‐
Multi‐Point systems.
RW Required Transmit power in dBm . This is a
nominal value while the actual transmit power
includes additional attenuation. The min and
max values are product specific. A change is
effective immediately.
RO
Current Link State. The value is active (3) during
normal operation.
RO
This parameter indicates if the device was
automatically selected into the radio link master
or slave. The value is undefined if there is no
link. The value is relevant only for point to
point systems.
RW Setting this parameter to 1 will cause the link to
restart the synchronization process.
C‐43