Cables and connectors
Cable ties
Sealing material
Waterproofing tape such as Scotch 23 Tape ¾" wide, from 3M to ensure IP‐67 compliant 
protection against water and dust
Cables and connectors
ODU grounding cable 10 AWG
ODU‐PoE cable (outdoor class, CAT‐5e, 4 twisted pairs, 24AWG):
• Up to 100 m. for 100BaseT connection. 
• For a 1000BaseT connection (HBS only) use an ODU‐PoE cable no longer than 75m.
 For 1000BaseT, you should use RADWIN supplied ODU‐PoE cables, which 
guarantees 1Gb performance. RADWIN cannot guarantee 1Gb 
performance if you use third party cables. 
Note
• External CAT‐5e cable diameter should be between 7‐9 mm to ensure waterproof 
sealing.
Safety Practices and Provisions
Preventing Overexposure to RF Energy
To protect against overexposure to RF energy, install the ODUs so as to provide and maintain 
minimal separation distances from all persons.
When the system is operational, avoid standing directly in front of the antenna. Strong RF 
fields are present when the transmitter is on. The ODU must not be deployed in a location 
where it is possible for people to stand or walk inadvertently in front of the antenna.
Grounding
All RADWIN products should be grounded during operation. In addition:
All ODUs should be earthed by a wire with diameter of at least 10 AWG.
RADWIN 5000 HPMP ODUs must be properly grounded to protect against lightning. It is 
the user's responsibility to install the equipment in accordance with Section 810 of the 
National Electric Code, ANSI/NFPA No.70‐1984 or Section 54 of the Canadian Electrical 
Code. These codes describe correct installation procedures for grounding outdoor units, 
masts, lead‐in wiring and discharge units. It also lays down the size of grounding 
conductors and connection requirements for grounding electrodes. RADWIN 5000 
HPMP ODUs must be grounded to a Protective Earth in accordance with the Local 
Electrical Regulations.
RADWIN 5000 HPMP User Manual
Release  3.5.70
4‐13