Using More than One HSS Unit
Condition 1: Cabling Sequence
1. Up to nine ODUs may be connected to the first HSS unit using HSS ports SYNC 1, SYNC 2, 
SYNC 3,... up to SYNC 9 in order without leaving empty ports.
2. The next available SYNC port of the first HSS unit should be connected to SYNC 10 
of the second HSS unit as shown in Figure
available port on the first HSS unit is SYNC 6.
3. The second HSS unit may be filled out with up to nine more ODUs in reverse order. 
That is, connect SYNC 9, SYNC 8, SYNC 7... as shown in Figure
Figure 14‐4: Cascading two HSS units
4. To add a a further HSS unit: Connect the next available SYNC port from the second 
HSS unit in descending order (SYNC 5 in Figure
unit.
5.
ODUs are connected to the third HSS unit from SYNC 2 as shown in Figure
ascending order:
Figure 14‐5: Cascading three HSS units