IDU Grounding
IDU Grounding
The IDU grounding post should be connected to the internal ground point, using a grounding
wire of at least 10 AWG. The grounding wire should be connected to a grounding rod or the
building grounding system.
The device should be permanently connected to ground.
The RADWIN Lightning Protection Kit
The RADWIN lightning protection kit contains the items as shown in
Figure 17-2: RADWIN Lightning Protection Kit
The lightning protector incorporates high-power gas discharge tube and current transistor
protection in a single protector unit. Technical specifications are shown in
Using Lightning Protectors and Grounding
A Grounding Kit and lightning protector Unit must be located near the ODU and properly
grounded as illustrated in Figures
RADWIN 5000 HPMP User Manual
17-3
and
17-4
below:
Release 3.2.00
Chapter 17
Figure
17-2:
Appendix
A.
17-3