Radwin 5000 HPMP User Manual page 402

5000 series point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

ODU ‐ HBS and HSU/HMU
Band
Regulation
Frequency  R ange     
(GHz)
5.928‐6.400
ETSI
5.895‐6.4050
6.4
5.890‐6.410
Universal
5.725‐6.400
The following Max Tx Power limitations apply to all products supporting the 3.5GHz ETSI 
band:
Occupied Sub‐
Center 
Band
Frequency
GHz
GHz
3.403‐3.490
3.413‐3.480
3.470‐3.610
3.480‐3.600
3.590‐3.710
3.600‐3.700
(†) The 3.480 GHz frequency is overlapped, occurring in two different bands 
as shown. If you wish to use the 3.480 GHz frequency, you should set Max 
TX Power to 17 dBm.
(‡) The 3.600 GHz frequency is overlapped, occurring in two different bands 
Note
as shown. If you wish to use the 3.600 GHz frequency, you should set Max 
TX Power to 23 dBm.
 
Management
Management Application (per 
sector)
Protocol
NMS
Environmental
Operating Temperatures
Humidity
Storage
RADWIN 5000 HPMP User Manual
Occupied 
CBW 
DFS?
(MHz)
(GHz)
5/10/
No
20
10
No
20
5/10/
No
20/40
Mode
Inactive
5, 10, 20
RADWIN Manager
SNMP and Telnet
RADWIN NMS ‐ RNMS
HBS/HSU: ‐35°C to +60°C / ‐31°F to +140°F
HBS/HSU: Up to 100% non‐condensing, IP67
‐40° to 85°C / ‐40°F to 185°F
Release 3.5.70
Compliance (Notes)
Low temperature, to ‐35°C
N/A
N/A Low temperature, to ‐55°C
Channel 
Max Tx 
Bandwidth
Power
MHz
dBm
17
23(†)
25(‡)
Frequency 
Step
KHz
250
A‐6

Hide quick links:

Advertisement

Table of Contents
loading