What You Need; Getting Started - Radwin 5000 HPMP User Manual

5000 series point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

What You Need
Changing any of VLAN, MIR, QoS, fixed rate, Spatial Multiplexing/Diversity antenna mode for 
one configured HSU at a given level, changes all other HSUs at that level. If you add a new 
HSU to a sector (by direct connection) at a given level, at sync time, it will acquire the existing 
parameters for that level.
A HMU must be able to send and receive service traffic while moving. To avoid service 
"glitches" while switching between successive HBSs, the HBS hand‐over time must be very 
small. For RADWIN 5000 HBSs it is typically less than 500 ms, depending on selection of 
Mobility channels.
A HMU detects that it is time to seek the next HBS when its rate drops below a predefined 
minimum capacity threshold based on a minimum supported rate. The HBS chosen will be the 
first found offering an RSS level above a minimum threshold (by default ‐60 dBm), which you 
can configure for each HMU. If no HBS can be found satisfying the latter criterion, then the 
HSU will sync with the HBS that has the highest RSS level (even though it is below the RSS 
Threshold).
It is up to the Mobility Project RF planners to ensure that HBSs are spaced with coverage 
overlap so that on the one hand the HSU RSS level does not fall so low that it loses 
synchronization between HBSs and on the other hand, successive HBSs do not interfere with 
one another.
In a Mobility project, it is fairly typical to use a fixed channel at each HBS and to have the 
HSUs configured to use the group of channels used by the HBSs so as to minimize hand‐over 
time.
What You Need
The RADWIN 5000 Mobility products are different from the fixed/nomadic products. They 
have different part numbers. Ensure that your HBS and HSUs as delivered are the Mobility 
models.
Each sector comes with a pre‐installed operating band. You can change it in the usual way. If 
you do ensure than each of the HSUs is changed. Alternatively (better), bring up the sector as‐
is and change the band sector‐wide.
Getting Started
We will create a sector with three HMUs. There is no difference in the log‐on procedure to 
the HBS. To avoid needless repetition and issues not really relevant to this chapter, we will 
start out with the HBS and the HMUs set to there factory defaults except for the IP addresses. 
We will maintain the IP addresses used in the previous chapters. In practice, the IP addresses 
of sector element may well be configured using Direct or Local Connection prior to 
reproduction of sector parameters from a "template" sector (such as we are creating) and 
most likely before deployment in the field.
Further we will not make any use of the Map view in this chapter. Once again, in practice, a 
Mobile system would be managed from a NOC using an enterprise standard NMS.
RADWIN 5000 HPMP User Manual
Release  3.5.70
11‐2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents