Private MIB Parameters
Private MIB Parameters
HBS
Table C‐2: Private MIB Parameters ‐ HBS (Sheet 1 of 33)
Name
winlink1000OduAdmProductType
winlink1000OduAdmHwRev
winlink1000OduAdmSwRev
winlink1000OduAdmLinkName
winlink1000OduAdmResetCmd
winlink1000OduAdmAddres
winlink1000OduAdmMask
winlink1000OduAdmGateway
winlink1000OduAdmBroadcast
winlink1000OduAdmHostsTable
winlink1000OduAdmHostsEntry
winlink1000OduAdmHostsIndex
winlink1000OduAdmHostsIp
winlink1000OduAdmHostsPort
winlink1000OduAdmHostsSecurity
Model
winlink1000OduAdmHostsUserNam
e
winlink1000OduAdmHostsPasswor
d
winlink1000OduAdmHostsIPv6
winlink1000OduBuzzerAdminState
winlink1000OduProductId
RADWIN 5000 HPMP User Manual
OID
Type
1.3.6.1.4.1.4458.1000.1.1.1
DisplayString
1.3.6.1.4.1.4458.1000.1.1.2
DisplayString
1.3.6.1.4.1.4458.1000.1.1.3
DisplayString
1.3.6.1.4.1.4458.1000.1.1.4
DisplayString
1.3.6.1.4.1.4458.1000.1.1.5
Integer
1.3.6.1.4.1.4458.1000.1.1.6
IPAddress
1.3.6.1.4.1.4458.1000.1.1.7
IPAddress
1.3.6.1.4.1.4458.1000.1.1.8
IPAddress
1.3.6.1.4.1.4458.1000.1.1.1
Integer
0
1.3.6.1.4.1.4458.1000.1.1.1
Integer
2.1.1
1.3.6.1.4.1.4458.1000.1.1.1
IPAddress
2.1.2
1.3.6.1.4.1.4458.1000.1.1.1
Integer
2.1.3
1.3.6.1.4.1.4458.1000.1.1.1
Integer
2.1.4
1.3.6.1.4.1.4458.1000.1.1.1
DisplayString
2.1.5
1.3.6.1.4.1.4458.1000.1.1.1
DisplayString
2.1.6
1.3.6.1.4.1.4458.1000.1.1.1
DisplayString
2.1.7
1.3.6.1.4.1.4458.1000.1.1.1
Integer
3
1.3.6.1.4.1.4458.1000.1.1.1
DisplayString
4
Release 3.5.70
Description
RO
ODU configuration description. 
RO
ODU Hardware Version. 
RO
ODU Software Version. 
RW Link Name. A change is effective immediately. 
RW Reset Command.    A set command with a value 
of 3 will cause a device reset.   HBS only: A set 
command with a value of 4 will cause a device 
reset for the entire sector.   The read value is 
always 0. 
RW ODU IP address. A change is effective after reset.    
The parameter is kept for backward 
compatibility.    Using the alternative parameter: 
winlink1000OduAdmIpParamsCnfg is 
recommended. 
RW ODU Subnet Mask. A change is effective after 
reset.    The parameter is kept for backward 
compatibility.    Using the alternative parameter: 
winlink1000OduAdmIpParamsCnfg is 
recommended. 
RW ODU default gateway. A change is effective after 
reset.    The parameter is kept for backward 
compatibility.    Using the alternative parameter: 
winlink1000OduAdmIpParamsCnfg is 
recommended. 
RW This parameter is reserved for the Manager 
application provided with the product. 
N/A Trap destinations table. Each trap destination is 
defined by an IP address and a UDP port.   Up to 
10 addresses can be configured. 
N/A Trap destinations table entry.   INDEX { 
winlink1000OduAdmHostsIndex } 
RO
Trap destinations table index. 
RW Trap destination IP address. A change is effective 
immediately. 
RW UDP port of the trap destination. A change is 
effective immediately. 
RW Security model used for this trap generation. 
RW User name used to generate the snmpv3 trap. 
RW Password used to generate the snmpv3 trap. 
RW Trap destination IPv6 address. A change is 
effective immediately. 
RW This parameter controls the activation of the 
buzzer while the unit is in install mode.   A 
change is effective immediately. The valid values 
are: disabled (0)  enabledAuto (1)  
enabledConstantly(2)  advancedAuto (3). 
RO
This parameter is reserved for the Manager 
application provided with the product. 
C‐6