Lightning Protector - Radwin 5000 HPMP User Manual

5000 series point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Lightning Protector
EMC
FCC
ETSI
CAN/CSA‐CEI/IEC
AS/NZS
Lightning Protector
Electrical
Compatible Interfaces
Data Rates
Nominal Operational Voltage
Maximum Operational Voltage
Maximum Continuous current
Impedance 
Connection type 
Pin-out
Pins Protected 
Response time 
Nominal discharge currents
Line to Line
Line to Ground
Impulse Discharge Current
20000 A, 8/20 μs
10000 A, 8/20 μs
2000 A, 10/350 μs
200 A, 10/1000 μs
200 A, 10/700 μs
Impulse Spark‐over
DC Spark-over ±20 % @ 100 V/s
100 V/μs
1000 V/μs
RADWIN 5000 HPMP User Manual
CFR47 Class B, Part15, Subpart B
EN 300 386, EN 301 489‐1, EN 301 489‐4
CISPR 22‐04 Class B
CISPR 22‐2004 Class B
10/100/1000BaseT
Up to 1000Mbps
48 VDC
60 VDC ‐ 650 mA
1 A
90 to 110 Ohm
RJ45 CAT 5e STP (shielded)
8 wires + shielding
All pins protected
<5 microseconds (with ODU)
500 A @ 8/20μs
2000 A @ 8/20μs
1 operation minimum
> 10 operations
1 operation
> 300 operations
> 500 operations
150 V
350 V
500 V
Release 3.5.70
A‐16