Radwin 5000 HPMP User Manual page 423

5000 series point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

MIB Parameters
<winlink1000><Section 1>...<Section n><Parameter Name>
For each of the configuration and control parameters (parameters with read‐write access), 
the "Description" column describes when the new value is effective. It is recommended that 
you perform the appropriate action to make the values affective immediately after any 
change. Where a change is required on both sides of the link, it is recommended that you 
change both sides of the link first and then perform the action.
Supported Variables from the RFC 1213 MIB
Table C‐1: Supported Variables
Name
OID
ifIndex
.1.3.6.1.2.1.2.2.1.1.x
ifDescr
.1.3.6.1.2.1.2.2.1.2
ifType
.1.3.6.1.2.1.2.2.1.3
ifSpeed
.1.3.6.1.2.1.2.2.1.5
ifPhysAddress
.1.3.6.1.2.1.2.2.1.6
ifAdminStatus
.1.3.6.1.2.1.2.2.1.7
ifOperStatus
.1.3.6.1.2.1.2.2.1.8
ifInOctets
.1.3.6.1.2.1.2.2.1.10.x
ifInUcastPkts
.1.3.6.1.2.1.2.2.1.11.x
ifInNUcastPkts
.1.3.6.1.2.1.2.2.1.12.x
ifInErrors
.1.3.6.1.2.1.2.2.1.14.x
RADWIN 5000 HPMP User Manual
Type
a
Integer
DisplayString
Integer
Gauge
Phys‐Address
Integer
Integer
Counter
Counter
Counter
Counter
Release 3.5.70
Description
RO
A unique value for each interface.Its value 
ranges between 1 and the value of 
ifNumber.The value for each interface must 
remain constant at least from one re‐
initialization of the entity's network 
management system to the next re‐
initialization.
RO
A textual string containing information 
about the interface.This string should 
include the name of the manufacturer, the 
product name and the version of the 
hardware interface.
RO
The type of interface, distinguished 
according to the physical/link protocol(s) 
immediately `below' the network layer in 
the protocol stack.
RO
An estimate of the interface's current 
bandwidth in bits per second.For interfaces 
which do not vary in bandwidth or for 
those where no accurate estimation can be 
made, this object should ontain the 
nominal bandwidth.
RO
The interface's address at the protocol 
layer immediately `below' the network 
layer in the protocol stack. For interfaces 
which do not have such an address (e.g., a 
serial line), this object should contain an 
octet string of zero length.
RW
The desired state of the interface. The 
testing(3) state indicates that no 
operational packets can be passed.
RO
The current operational state of the 
interface. The testing(3) state indicates 
that no operational packets can be passed.
RO
The total number of octets received on the 
interface, including framing characters.
RO
The number of subnetwork‐unicast packets 
delivered to a higher‐layer protocol.
RO
The number of non‐unicast (i.e., 
subnetwork‐ broadcast or subnetwork‐
multicast) packets delivered to a higher‐
layer protocol.
RO
The number of inbound packets that 
contained errors preventing them from 
being deliverable to a higher‐layer 
protocol.
C‐4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents