Throughput Checking - Radwin 5000 HPMP User Manual

5000 series point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Software Upgrade recommended
Software Upgrade recommended
This is also an advisory message. It typically occurs with a new HBS or new HSUs added to a 
sector.
If the upgrade is not carried out, then the HBS or HSU (s) will ope rate with limited or 
degraded functionality. This message may appear for an active HBS or any HSU in the sector, 
registered or not.
Software Upgrade required
This message will be displayed if a product band ID mismatch is detected.
Thus for a HBS, it cannot occur unless one or more HSUs are registered. Affected HSUs will 
always show it as depicted above in Figure
For such HSUs, traffic is disabled and the only services available are Change Band and 
Software Upgrade.
Throughput Checking
In this mode, RADWIN 5000 HPMP estimates Ethernet throughput by filling frames over the 
air to maximum for 30 seconds. This mode should not influence service. The test may be 
carried out for the HBS or an HSU.
To use Throughput Checking:
1. HBS: Chose Estimated Throughput as shown:
HSU from HBS: Chose Estimated Throughput as shown:
RADWIN 5000 HPMP User Manual
12‐4 above.
Release  3.5.70
12‐6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents