Figure 13-1 Interference; Figure 13-2 Collocated Units; Figure 13-3 Collocated Units - Radwin 5000 HPMP User Manual

5000 series point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

RADWIN HSS
Figure 13‐1: Interference caused by collocated units
Adding HSS removes interference as shown in the next two figures:
Figure 13‐2: Collocated units using Hub Site Synchronization (1)
Figure 13‐3: Collocated units using Hub Site Synchronization (2)
The units are connected to each other with HSS cables and HSS Distribution Units.
One of the radios in the site is defined as HSS Master and generates synchronization pulses.
The other collocated radios in the site ‐ the HSS Clients, are connected to the HSS Master and 
synchronize their transmission to the pulses. An HSS Client can be configured to work in one 
of two modes:
RADWIN 5000 HPMP User Manual
Release  3.5.70
13‐2