Radwin 5000 HPMP User Manual

Radwin 5000 HPMP User Manual

Point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Quick Links

RADWIN 5000 HPMP
Point to Multipoint Broadband Wireless
USER MANUAL
RELEASE 3.2.00
UM 5000-3200/08.11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5000 HPMP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Radwin 5000 HPMP

  • Page 1 RADWIN 5000 HPMP Point to Multipoint Broadband Wireless USER MANUAL RELEASE 3.2.00 UM 5000-3200/08.11...
  • Page 2: User Manual

    RADWIN protected under international copyright law and shall be and remain solely with RADWIN. The RADWIN name is a registered trademark of RADWIN Ltd. No right, license, or interest to such trademark is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark.
  • Page 3 Italy Ciudad Merliot El Salvador Tel:+390815564116 Tel: +503 2278-5628 sales@radwin.com Fax: +39335433620 Email: salesit@radwin.com Email: RADWIN South East Asia All Season Mansion 87/38 Wireless Road Lumpinee Bangkok ,10330 Thailand Tel: +66811707503 sales@radwin.com Email: RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 4: Regulatory Compliance

    The installer should configure the output power level of antennas according to country regulations and antenna type. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 5 2. For protection of ODU against direct lightning strikes, appropriate requirements of NFPA 780 should be considered in addition to NEC. 3. For Canada, appropriate requirements of the CEC 22.1 including Section 60 and additional requirements of CAN/CSA-B72 must be considered as applicable. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 6 Chapter 9 Hub Site Synchronization Chapter 10 Using the RADWIN GSU Part 5: Advanced Installation Topics Chapter 11 Software Upgrade Chapter 12 VLAN Functionality with RADWIN 5000 HPMP Chapter 13 False Radar Mitigation Facilities Chapter 14 FCC/IC DFS Considerations Chapter 15 Quality of Service...
  • Page 7: Table Of Contents

    Full Table of Contents Part 1: Basic Installation Chapter 1 Introduction Welcome to RADWIN 5000 HPMP! ............... 1-1 RADWIN 5000 HPMP Highlights..............1-1 What’s New in Release 3.2.00 ..............1-1 Some Terminology ..................1-2 ............1-2 Key features of RADWIN 5000 HPMP ...............
  • Page 8 Base Station Panel HBS Events Log ..................4-11 ..............4-12 HBS Main Window - HSUs Panel Exploring the RADWIN Manager Main Window - HSU ........4-15 Logging on to an HSU................4-15 ................4-17 HSU Main Button Menu HSU Link Status ..................
  • Page 9 RADWIN Manager Traps ................8-13 Active Alarms .................... 8-14 Other Diagnostic Aids ................8-14 Link Budget Calculator ................8-14 ................... 8-15 Online Help .................. 8-15 Customer Support Part 4: Site Synchronization Chapter 9 Hub Site Synchronization RADWIN 5000 HPMP User Manual Release 3.2.00 viii...
  • Page 10 Part 5: Advanced Installation Topics Chapter 11 Software Upgrade What is the Software Upgrade Utility? ............11-1 Upgrading an Installed Sector ..............11-2 Chapter 12 VLAN Functionality with RADWIN 5000 HPMP VLAN Tagging - Overview ................12-1 .................. 12-1 VLAN Terminology ..........
  • Page 11 Grounding for Indoor/Outdoor Units ............17-2 ..................17-2 ODU Grounding ..................17-3 IDU Grounding The RADWIN Lightning Protection Kit ............17-3 Using Lightning Protectors and Grounding........... 17-3 Mounting RADWIN Lighting Protection unit ..........17-6 Internal ESD Protection circuits ..............17-7 Chapter 18 Link Budget Calculator Overview ....................
  • Page 12 Antenna Issues ...................E-1 About Single and Dual Antennas..............E-1 ............E-1 Dual Antennas at the HBS and an HSU ..............E-2 Single Antennas at Both Sites ..........E-2 Single at One Site, Dual Antennas at the Other RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 13 Contenu du kit de montage ODU ................F-3 Montage sur un pylône Montage sur un mur ................. F-5 ..............F-6 Montage d'une antenne externe ......... F-6 Contenu du kit de montage d'une antenne externe Index RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 14: List Of Figures

    .............. 6-16 IGURE ETTING THERNET SERVICES 6-10 R ......6-18 IGURE ESTORE ACTORY ETTINGS AND ICENSE CTIVATION 6-11 HSU I .............. 6-20 IGURE NTERCOMMUNICATION 6-12 HSU C (HBS) ..........6-21 IGURE ONFIGURATION WINDOW RADWIN 5000 HPMP User Manual Release 3.2.00 xiii...
  • Page 15 OTE THE STOP BUTTON 11-6 S ........11-4 IGURE OFTWARE UPGRADE COMPLETED SUCCESSFULLY 12-1 VLAN RADWIN 5000 HBS ....... 12-2 IGURE SCENARIOS HANDLE BY 12-2 S ..... 12-2 IGURE EPARATING CLIENT DATA STREAMS USING DOUBLE TAGGING RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 16 IGHTNING PROTECTOR AND GROUNDING AT BUILDING ENTRY POINT 18-1 F ................18-4 IGURE RESNEL ZONE 18-3 L ............18-5 IGURE UDGET WINDOW STARTUP 18-4 RADWIN 5000 HPMP LBC ........18-6 IGURE MAIN WINDOW 18-5 B ................18-7 IGURE AND SELECTOR 18-6 C ......18-8...
  • Page 17: List Of Tables

    RAPS D-1 S RADWIN 5000 HPMP FCC IC P ..D-1 ABLE AFETY ISTANCES FOR RODUCTS D-2 S RADWIN 5000 HPMP ETSI P ....D-1 ABLE AFETY ISTANCES FOR RODUCTS E-1 MIMO - D ..............E-3 ABLE IVERSITY SETTINGS E-2 RADWIN 5000 HPMP A ............E-3...
  • Page 18: Part 1: Basic Installation

    RADWIN 5000 HPMP Point to Multipoint Broadband Wireless USER MANUAL RELEASE 3.2.00 Part 1: Basic Installation UM 5000-3200/08.11...
  • Page 19: Chapter 1 Introduction

    Chapter 1 Introduction Welcome to RADWIN 5000 HPMP! RADWIN 5000 HPMP delivers up to 200Mbps and is the ideal choice for last mile enterprise connectivity and high-end applications that demand assured performance with guaranteed bandwidth per subscriber. RADWIN 5000 HPMP sector base station delivers up to 200Mbps, providing the highest end user capacity in the market to best support data and high resolution video applications, today and tomorrow.
  • Page 20: Some Terminology

    Unit radios. The SUs are sometimes called Customer Premises Equipment (CPEs). The terminology comes from the field of telephony. The RADWIN 5000 HPMP product suite supports considerably higher capacity than other cur- rent technologies (such as Wi-Max). We distinguish between generic BSs and SUs and RAD- WIN units, relabeling the latter, HBSs and HSUs (H = high capacity).
  • Page 21: Radwin 5000 Hpmp Components

    ODU antenna An HSU consists of a RADWIN 55xx HSU ODU. It may be a small form factor (SFF) model with a built in antenna, or a regular integrated or connectorized unit. The latter should use a dual pole antenna for best performance.
  • Page 22: The Radwin Manager

    Where a term is defined or introduced for the first time, it is shown in Boldface. You will have noticed this usage in the Terminology section above. Software The RADWIN Manager is a Microsoft Windows application following the user interface con- ventions of familiar Microsoft Windows programs. RADWIN 5000 HPMP User Manual...
  • Page 23: Viewing And Printing

    For good legibility, use a commercial grade laser printer. A color printer is of course best, however a monochrome printer set to use gray-scale gives acceptable results • Better quality ink jet printers also give good output RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 24: Chapter 2 Site Preparation

    RADWIN 5000 HPMP offers a wide operating frequency range. A free frequency channel must be determined within the operating range, for optimum performance.
  • Page 25: Stage 1: Preliminary Survey

    7. If the sites chosen do not meet requirements, consider alternative sites. 8. Use the Link Budget Calculator (on the CD supplied with the equipment or using the RADWIN Manager) to determine the expected performance. RADWIN 5000 HPMP User Manual...
  • Page 26: Stage 2: Physical Survey

    If the site is suitable, continue with stage 3, the RF survey • If the site is not suitable, survey another site Additional Outdoor Site Requirements The ambient outdoor operating temperature should be -35 to 60C (-31 to 140F). RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 27: Additional Indoor Site Requirements

    RADWIN unit. • If one or more collocated units are not RADWIN units, ensure that there is a physical separation of at least three meters between a RADWIN unit and any other collocated radio on the site.
  • Page 28: Chapter 3 Hardware Installation

    Hardware Installation This chapter sets out the requirements and procedures for the hardware installation and alignment of a RADWIN 5000 HPMP sector in accordance with the prior planning as set out in Chapter 2. It is intended to guide qualified field technicians.
  • Page 29: Protection Against Lightning

    • Use extreme care when working at heights. • When using an AC power source for RADWIN 5000 HPMP PoEs always use the AC power adapter supplied by RADWIN. • Use the right tools. In addition to standard tools required for any kind of ODU or...
  • Page 30 Figure 3-2: ODU Form Factors • Integrated Antenna ODU This ODU has an integrated 370mm (1.2ft) flat panel antenna. The ODU contains both the radio and the antenna as a single unit housed in a weatherproof case. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 31: External Antenna Package Contents

    The HBS requires a dual pole sector antenna. HSUs may use any suitable dual pole directional antenna. External antennas are available for the RADWIN 5000 HPMP radios, varying in operating fre- quencies, form factor, size and gain. Figure 3-3: External Antennas for use with RADWIN 5000 HBS - Left: 60°...
  • Page 32: Power Over Ethernet (Poe) Devices

    Power Over Ethernet (PoE) Devices GbE PoE RADWIN’s Gigabit Power over Ethernet (GbE PoE) device provides data and power to RADWIN 5000 5000 outdoor units. The PoE device is available with a variety of AC cables with different plug types.
  • Page 33: Hub Site Synchronization (Hss) Unit

    The GPS-based synchronization unit (GSU) is designed to handle inter-site interferences under large-scale deployment scenarios. The GSU is an outdoor unit consisting of a standard WinLink 1000 enclosure, a GPS antenna and a PoE device. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 34: Additional Tools And Materials Required

    Figure 3-9: General GSU configuration Chapter 10 for further details about the use of GSU. Additional Tools and Materials Required The following is a list of the equipment and materials required to install RADWIN 5000 HPMP hardware. Tools and Materials •...
  • Page 35: Hardware Installation Sequence

    • A crossed Ethernet LAN cable is required if you set up ODUs using the “Local Connec- tion” method. Hardware Installation Sequence The following steps are required to install a RADWIN 5000 HPMP system: 1. Mounting the ODUs, page 3-9.
  • Page 36: Outdoor Installation

    1. Ensure that the ODU is properly grounded. 2. Mount the ODU onto the pole or wall. Ensure that the unit is oriented so that the cable connectors are at the bottom. (If they are on top, water may penetrate RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 37: Mounting External Antennas

    The use of lightning protection is dependent on regulatory and end user requirements. The RADWIN 5000 HPMP ODU is designed with surge limiting circuits to minimize the risk of dam- age due to lightning strikes. RADWIN recommends the use of additional surge arrestor devices to protect the equipment from nearby lightning strikes.
  • Page 38: Installing A Sector Using Poe Devices

    4. Provided that an HSU detects the signal from the HBS, the ODU starts beeping 20 seconds after power up, and continues beeping until the HSU is aligned to the HBS, and the alignment is complete. RADWIN 5000 HPMP User Manual Release 3.2.00 3-11...
  • Page 39 Long beep and short pause is 'signal quality decreased' Note • One beep and a long pause is 'no air link' • Any other signal does not relate to antenna alignment 7. Secure the HSU antenna to the pole/wall. RADWIN 5000 HPMP User Manual Release 3.2.00 3-12...
  • Page 40: Part 2: Sector Installation

    RADWIN 5000 HPMP Point to Multipoint Broadband Wireless USER MANUAL RELEASE 3.2.00 Part 2: Sector Installation UM 5000-3200/08.11...
  • Page 41: What We Will Do Here

    This chapter is a quick “hands-on” tour of a running sector. We show you how to install the RADWIN Manager software on your managing PC, connect it to an operating base station and then log on. We then explain the use of the various objects on the RADWIN Manager main window.
  • Page 42: Installing The Software

    Any modern Web browser to view additional material, use the Web Interface or get help from the RADWIN Web site. Installing the Software Any PC running the RADWIN Manager application can be used to configure a RADWIN 5000 HPMP sector. ...
  • Page 43: Getting Started With The Radwin Manager

    Getting Started with the RADWIN Manager Chapter 4 Getting Started with the RADWIN Manager We will look at a preconfigured sector, setup as follows: Table 4-2: Preconfigured setup Unit Location Attribute Value Remark IP Address 192.168.10.200 All communicating HSUs and HBS in Net Mask 255.255.255.0...
  • Page 44: The Radwin Manager Log-On Concept

    The Log-on dialog box appears. Figure 4-2: Log-on window The RADWIN Manager log-on Concept The RADWIN Manager provides three levels of access in one of two entry modes. To see them, click Options at any time in the Log on window (Figure 4-2 above).
  • Page 45 (or regulation). The latter function has legal ramifications, requiring familiarity with local regulations. If you are connecting through the RNMS server check the RMNS connect button and enter your server IP address. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 46 Leave the default Community passwords, for read-write, public for read-only. • If you are a user with read-only permission, then you may only log Note on as Observer. The RADWIN Manager main window is displayed: RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 47: Log-On Errors And Cautions

    Log-on Errors and Cautions Chapter 4 Figure 4-5: Opening RADWIN Manager window - HBS Log-on Errors and Cautions Unsupported Device Attempting to connect to an unsupported device on an otherwise valid IP address (for exam- ple, a LAN printer) will result in the following error message:...
  • Page 48: Incorrect Password

     To deal with lost or forgotten Community Strings: 1. Send an email request for to RADWIN Customer Support for an alternative key. Your email must include the ODU serial number shown on the adhesive sticker on rear of one of your ODUs.
  • Page 49: Hbs Main Button Menu

    Normally you would not leave unallocated time slots unless you intended to add more HSUs. Every HSU requires at least one time slot. Base Station Panel The displayed items in the Base Station panel are straight forward. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 50 HSU Connection Table page 6-19 Reset the HBS Deactivate the HBS page 5-31 The foregoing description relates to an activated HBS. The Detail Panel title bar for an inactive HBS looks like this: RADWIN 5000 HPMP User Manual Release 3.2.00 4-10...
  • Page 51: Hbs Events Log

    IP address of the ODU that initiated alarm. For complete information about internal traps and alarms see Chapter The events are displayed in the Events Log in the lower right-hand panel of the RADWIN Manager main window: Figure 4-12: Events Log panel The events log provides a color coded event list.
  • Page 52: Hbs Main Window - Hsus Panel

    If you have a large number of HSUs in the sector, it may be helpful to filter the display. You have the following choices: The following case has colored fields indicating a problem requiring your attention: Figure 4-14: HBS Main Window (Reduced) - indicating a problem RADWIN 5000 HPMP User Manual Release 3.2.00 4-12...
  • Page 53 Table 4-6: HSU Status ball color codes Color Description Green Registered, in sync Registered, no sync Grey Deregistered Purple Authentication error Blue Belongs to another sector Right click an HSU to get its context menu: RADWIN 5000 HPMP User Manual Release 3.2.00 4-13...
  • Page 54 Configure Site configuration for the HSU page 6-20 Recent Events Recent events log per HSU page 8-5 Performance Performance Monitoring per HSU page 8-7 Monitoring Active Alarms Display Active Alarms page 8-14 RADWIN 5000 HPMP User Manual Release 3.2.00 4-14...
  • Page 55: Exploring The Radwin Manager Main Window - Hsu

    Exploring the RADWIN Manager Main Window - HSU Chapter 4 Table 4-7: HSU main window detail display context menu and button bar functions (Contin- Menu Menu Item Purpose Reference Icon Estimate Estimate throughput per HSU page 8-4 Throughput Service evaluation and Time Slot allocation...
  • Page 56 Logging on to an HSU Chapter 4 Figure 4-19: Opening RADWIN Manager window - HSU RADWIN 5000 HPMP User Manual Release 3.2.00 4-16...
  • Page 57: Hsu Main Button Menu

    Run and store diagnostics for all or some members of a sector Log Off Return to log-on window Link Budget Calculator Help Check for updates About Help Button View this User Manual HSU Link Status RADWIN 5000 HPMP User Manual Release 3.2.00 4-17...
  • Page 58: Hsu Events Log

    They are also functionally identical for both the HBS and HSUs. Each technician servicing a sector will need to set up his managing computer (typically a laptop) with his own preferences. Note RADWIN 5000 HPMP User Manual Release 3.2.00 4-18...
  • Page 59: Monitor

    For an HSU, it will record the information just for that HSU. You should use distinctive file names for HBS and HSU Monitor files. The content of the Monitor file will be discussed in more detail in Chapter RADWIN 5000 HPMP User Manual Release 3.2.00 4-19...
  • Page 60: Events

    You may also choose a location and file name for the events log for storage. These settings are again, per HBS or HSU. To avoid over-writing, you should use file names reflecting their source ODU. RADWIN 5000 HPMP User Manual Release 3.2.00 4-20...
  • Page 61: Advanced

    What Comes Next? The purpose of this chapter was to offer an overview of a running RADWIN 5000 HPMP a sec- tor. The next three chapters will cover respectively, detailed sector setup considerations, sec- tor management and monitoring and diagnostics. The foregoing background should provide sufficient “signposts”...
  • Page 62: Chapter 5 Installing The Sector

    Bringing up the HSUs - configuration and registration The same RADWIN Manager program is used for both the HBS and the HSUs. Much of the process is common to both types of ODU. We will cover the HBS in detail; for the HSUs we will concentrate on those items which are different.
  • Page 63: Workflow

    Prior to commencing, you should have written sector plan along the lines of Table 5-2. Default RADWIN 5000 HPMP Settings The default settings of the RADWIN 5000 HPMP configuration parameters are listed in Table 5-1 below. Table 5-1: Default settings...
  • Page 64 Default RADWIN 5000 HPMP Settings Chapter 5 Table 5-1: Default settings (Continued) Unit Parameter Default Value IP Address 10.0.0.120 Net Mask 255.0.0.0 Default Gateway 0.0.0.0 Location Location Contact Person Name Name RADWIN Manager log-on passwords Observer admin Operator admin Installer...
  • Page 65: Configuring The Sector Out Of The Box - Ip Addresses

    10.0.0.100, Subnet Mask 255.255.255.0 and Default Gateway 0.0.0.0. Ensure that you have a direct LAN connection to the ODU, run the RADWIN Manager and log- on to it. Figure 5-1: Logging on with factory default IP address...
  • Page 66 Further, it will throw any other links on the net- work into Installation or Inactive mode. Warning • Network log on (IP address to the ODU) is recommended. Here is the main display: RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 67 Notice the red icon on the top left corner of the window. It will change to green as soon as the HBS is configured and activated.  To pre-configure the HBS and HSUs prior to deployment in the field: 1. Click the configuration button . The Base Station site configuration widow opens: RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 68 Configuring the Sector out of the Box - IP Addresses Chapter 5 Figure 5-4: Site Configuration prior to definition 2. Click the Management tab. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 69 HSU site configuration dialogs will be the same. At this point you should field-install the units according to the guidelines in Chapter 3. You should now revert your network card to the Sector Subnet. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 70: Activating The Hbs

    Activating the HBS enables it to be discovered by the HSUs. An Activation Wizard will guide you through the process.  To activate an HBS: 1. Click the Activate button. The Activation Wizard opens. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 71 Activating the HBS Chapter 5 2. Click Next: Enter the Sector ID, Name and Location. All fields are mandatory. Here are entries in accordance with Table 5-2: RADWIN 5000 HPMP User Manual Release 3.2.00 5-10...
  • Page 72 It is best left as is if there is no pressing need to change it. If you skipped an entry, it will be framed in red like this: Note 3. From the previous Activation Wizard window, click Next. RADWIN 5000 HPMP User Manual Release 3.2.00 5-11...
  • Page 73 4. The next window is used to set the frequency and channels. The default frequency for the installed band is shown. Click the right hand selector wheel to see other available frequencies: RADWIN 5000 HPMP User Manual Release 3.2.00 5-12...
  • Page 74 Activating the HBS Chapter 5 Choosing Other enables you to move up and down by increments of 5 MHz: 5. Choose the required Channel Bandwidth: RADWIN 5000 HPMP User Manual Release 3.2.00 5-13...
  • Page 75 40 MHz Channel Bandwidth to enable it. Note 6. To use ACS, check the Automatic Channel Selection box: You can perform a customized channel selection or click Select All to check all the channel boxes as shown:” RADWIN 5000 HPMP User Manual Release 3.2.00 5-14...
  • Page 76 Appendix Choose your Antenna Type, Required Tx Power, Antenna Gain and Cable Loss. We will set Required Tx Power to 6 dBm for our example. Click Next. RADWIN 5000 HPMP User Manual Release 3.2.00 5-15...
  • Page 77 8. The Summary window of the Wizard is displayed. Check that all information showed is correct and click Activate. After a few moments the sector HSUs will be displayed in the Manager HSU panel. RADWIN 5000 HPMP User Manual Release 3.2.00 5-16...
  • Page 78 Further, you may have observed that operating frequency 5.805 GHz shown, is not what we chose (5.820 GHz). The HBS tries to optimize the frequency to minimize the kind of problem displayed above. RADWIN 5000 HPMP User Manual Release 3.2.00 5-17...
  • Page 79: Pre-Configuring The Hsus For Service

    To pre-configure an HSU for service from the HBS: 1. Right click an HSU to get its context menu: Figure 5-8: HSU Context menu 2. Click Configure. The Configuration dialog is displayed. Enter a Name Contact and Location: RADWIN 5000 HPMP User Manual Release 3.2.00 5-18...
  • Page 80 Location is a site name - typically a building or tower name. Contact is the contact person at that Location and Name is the Contact location. It might be just a tele- phone number. Here are our entries: RADWIN 5000 HPMP User Manual Release 3.2.00 5-19...
  • Page 81 Click Tx & Antenna. The following dialog is displayed: Set the Antenna Type, Required Tx Power, Antenna Gain and Cable Loss as required. For our example, we set Tx Power to 5 dBm. 4. Open the Management tab. RADWIN 5000 HPMP User Manual Release 3.2.00 5-20...
  • Page 82 Set the HSU IP address, Subnet mask and Default Gateway. You may defer the trap destinations, VLAN and Protocol settings for now.Here are our settings for this HSU: 5. Click OK. You will be offered a cautionary message: RADWIN 5000 HPMP User Manual Release 3.2.00 5-21...
  • Page 83: Pre-Configuring From A Direct Link

     To pre-configure an HSU for service by direct link: 1. Connect your managing computer to the HSU and log on using Local Connection. RADWIN 5000 HPMP User Manual Release 3.2.00 5-22...
  • Page 84 Pre-configuring from a Direct Link Chapter 5 2. Click the (top left hand) Configure button. RADWIN 5000 HPMP User Manual Release 3.2.00 5-23...
  • Page 85 HSU IP address, Subnet Mask and Default Gateway. 5. Click OK to accept your entries. You will be offered the following disconnection warn- ing: 6. Click Yes. You will see your configuration changes on the main window: RADWIN 5000 HPMP User Manual Release 3.2.00 5-24...
  • Page 86: The Final Outcome

    You may now carry out any other adjustments to HS_10.101 either from the HBS or by direct connection. Notice that as we did for HSU_10.102, we adjusted the Tx Power to keep the RSS at a reasonable level. RADWIN 5000 HPMP User Manual Release 3.2.00 5-25...
  • Page 87: Registering The Hsus For Service

    We continue our illustration using HSU at HSU_10.102.  To register an HSU for service: 1. Right click an HSU to get its context menu: 2. Click Register... The Registration window opens: RADWIN 5000 HPMP User Manual Release 3.2.00 5-26...
  • Page 88 The choice is HSU specific. For further details about MIMO/Diversity antenna mode, Appendix 5. Click the Evaluate button. Service evaluation takes a few seconds during which the window is darkened and inactive. Upon completion you may assign time slots to the HSU: RADWIN 5000 HPMP User Manual Release 3.2.00 5-27...
  • Page 89 7. Use the sliders to set uplink and downlink MIR. You may defer this and carry it out using the HSU Configure option. The MIR acts a s a “throttle”. 8. Click Register it to complete the process. Here is the result for our example: RADWIN 5000 HPMP User Manual Release 3.2.00 5-28...
  • Page 90 Observe that the registered HSU LED is now green and that the Time Slots bar on the left reflects the proportion of time slots allocated. 9. Repeat steps 1 to 8 for other HSUs. Here is the result for our example: RADWIN 5000 HPMP User Manual Release 3.2.00 5-29...
  • Page 91: Choosing Diversity Antenna Mode During Registration

    The throughput on this HSU has dropped to about half of its previous value. The other HSU is left unchanged. This underlines the flexibility of the RADWIN 5000 HPMP system which enables HSUs to be independently configured depending on their particular location.
  • Page 92: Deactivating The Hbs

    Where has my HSU gone? Suppose that you installed two collocated HBSs with contiguous sectors. It is possible that an HSU located close to the common sector boundary may “discover” the wrong HBS. A HSU can RADWIN 5000 HPMP User Manual Release 3.2.00 5-31...
  • Page 93 Where has my HSU gone? Chapter 5 be “forced” across to another HBS by changing its Sector ID to that of the required HBS. The method for doing this is covered in Chapter RADWIN 5000 HPMP User Manual Release 3.2.00 5-32...
  • Page 94: Part 3: Sector Management

    RADWIN 5000 HPMP Point to Multipoint Broadband Wireless USER MANUAL RELEASE 3.2.00 Part 3: Sector Management UM 5000-3200/08.11...
  • Page 95: Chapter 6 Managing The Sector

    The Refresh button restores the current window to its previous state abandoning any changes you made, provided that you did not click Apply or OK. We will work through each of the Configuration tabs in turn: RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 96: System

    System Chapter 6 System These items are convenience fields. Name and Location are typically entered during HBS activation. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 97: Air Interface

    5). Changing the Sector ID will “percolate” to all registered HSUs. It will of course, be “picked up” by newly installed and registered HSUs. Channel Bandwidth and Channel Selection changes will all be sector-wide. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 98: Tx And Antenna

    For the HBS, changes made here may affect link quality and in the case of antenna type, cause a sector re-sync. Changing the antenna type for an HSU will cause a re-sync to that site only. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 99: Hub Site Sync [Hss]

    Chapter 6 Hub Site Sync [HSS] The External Pulses detected in this example, come from a collocated RADWIN 2000 ODU configured as Hub Sync Master. (A WinLink 1000 would have done just as well.) To enable HSS, check the Enabled check box.
  • Page 100: Management

    If you set the IP and related addresses correctly, there should be little to change here. The three sub-windows, Trap Destinations, VLAN Management and Protocol dialogs are generic to the HBS nad the HSUs (direct or over-the-air) and are discussed below. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 101 VLAN for Management Management VLAN Configuration Figure 6-1: VLAN for Management VLAN IDs are used by RADWIN products in three separate contexts: Management VLAN, Traffic VLAN and Ethernet Ring. It is recommended that you use different VLAN IDs for each context.
  • Page 102 • For further details about the Web Interface, see Chapter SNMP access is on by default for RADWIN 5000 HPMP and cannot be disabled. Note Telnet and Web Interface access modes when available, are site specific. If for example, you want Telnet access from specific sector members, you should enable it for these sites and dis- able it elsewhere.
  • Page 103: Inventory

    Inventory Chapter 6 Inventory You might like to capture or copy the information here: The Inventory information will be required by Customer Support should you require assis- tance. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 104: Security

    Here are the details: wireless-p2mp The default password is . Optionally, you can change the link password as explained here.  To change the link password: 1. Open the Security tab (Figure 6-2). RADWIN 5000 HPMP User Manual Release 3.2.00 6-10...
  • Page 105 Continue with the next step. 3. Enter a new password. 4. Retype the new password in the Confirm field. 5. Click OK. 6. Click Yes when asked if you want to change the link password. RADWIN 5000 HPMP User Manual Release 3.2.00 6-11...
  • Page 106 ODU if the read-write or the read Community values are forgot- ten. A new Community value may be obtained from RADWIN Customer Support for the pur- pose of setting new Community. You must also have available the serial number or the MAC address of the ODU.
  • Page 107 If both the read-write Community and the alternative Community key are unavailable, then an alternative Community key can be obtained from RADWIN Customer Support using the ODU serial number or MAC address. The serial number is located on the product label. The serial number and the MAC address are displayed in the Site Configuration inventory tab.
  • Page 108: Date And Time

    To set the date and time: 1. Determine the IP address of the NTP server to be used. 2. Test it for connectivity using the command (Windows XP), for example: w32tm /stripchart /computer:216.218.192.202 RADWIN 5000 HPMP User Manual Release 3.2.00 6-14...
  • Page 109 5. To manually set the date and time, click Change and edit the new values. Figure 6-8: Change Date and Time 6. Click OK to return to the Configuration dialog. 1. Greenwich Mean Time RADWIN 5000 HPMP User Manual Release 3.2.00 6-15...
  • Page 110: Ethernet Service Configuration

    The ODU Ethernet port mode is configurable for line speed (10/100/1000BaseT) and duplex mode (half or full duplex). Line speed 1000BaseT is only available if the HBS is connected to A GbE PoE device. RADWIN 5000 HPMP User Manual Release 3.2.00 6-16...
  • Page 111 To install and use the Ethernet QoS feature, see Chapter Advanced: Broadcast/Multicast Flooding Protection Broadcast/Multicast Flooding Protection provides a measure of protection by limiting multicast and broadcast packets to mo more than 12.5% of available capacity. RADWIN 5000 HPMP User Manual Release 3.2.00 6-17...
  • Page 112: Operations

    Operations This section applies to both HBSs and HSUs. Reverting to Factory Settings Figure 6-10: Restore Factory Settings and License Activation Clicking the Restore Defaults button opens the following self explanatory dialog: RADWIN 5000 HPMP User Manual Release 3.2.00 6-18...
  • Page 113: Advanced: False Radar Mitigation For Hbs

    (a text file) you will need to use the License File option. In some instances it may involve purchasing the relevant license from RADWIN. You should contact Customer Service for details. You will find the technical steps required to obtain and...
  • Page 114: Configuring An Hsu From The Hbs Main Window

    The Backup and Restore buttons have the same functionality as the corresponding buttons for the HBS. They provide for backup and restore of the HSU software. The Buzzer button may set or mute the buzzer. RADWIN 5000 HPMP User Manual Release 3.2.00 6-20...
  • Page 115: System

    We will work through each of the Configuration tabs in turn: System Figure 6-12: HSU Configuration window (HBS) These items are convenience fields. They are typically entered before the sector is brought RADWIN 5000 HPMP User Manual Release 3.2.00 6-21...
  • Page 116: Tx & Antenna

    Figure 6-13: HSU Configuration - Setting antenna type and parameters The remarks about changing the HBS parameters also apply here. Changing the antenna type will cause a re-sync between the HSU and the HBS. RADWIN 5000 HPMP User Manual Release 3.2.00 6-22...
  • Page 117: Management

    Management Chapter 6 Management Figure 6-14: HSU Configuration - IP addresses The functionality is identical as that for the HBS. RADWIN 5000 HPMP User Manual Release 3.2.00 6-23...
  • Page 118: Inventory

    Inventory Chapter 6 Inventory You should note the details for each HSU. RADWIN 5000 HPMP User Manual Release 3.2.00 6-24...
  • Page 119: Security

    Security Chapter 6 Security You may change the SNMP community strings only for the HSU from here. You cannot change the Link password from an HSU. RADWIN 5000 HPMP User Manual Release 3.2.00 6-25...
  • Page 120: Date & Time

    Date & Time Chapter 6 Date & Time The functionality is identical as that for the HBS. RADWIN 5000 HPMP User Manual Release 3.2.00 6-26...
  • Page 121: Ethernet

    The Maximum Information Rate (MIR) was initially set during HSU Registration. You may change it here. VLAN Configuration For Traffic VLAN configuration, see Chapter QoS Configuration QoS configuration is described in Chapter RADWIN 5000 HPMP User Manual Release 3.2.00 6-27...
  • Page 122: Operations

    Chapter 6 Operations This functionality is identical to that for the HBS. Advanced: False Radar Mitigation This tab is only visible if • You are using a Regulation requiring Radar Channel Avoidance and RADWIN 5000 HPMP User Manual Release 3.2.00 6-28...
  • Page 123: Replacing An Hsu

    1. Right click the defective unit to obtain the context menu. It has a new item: Replace. 2. Click Replace. Your are offered a list of HSUs available as replacements. In our example there is one: 10.102. RADWIN 5000 HPMP User Manual Release 3.2.00 6-29...
  • Page 124 5. Cancel the current dialog and right click 10.102. Use Configure | Tx & Antenna set the required antenna type (sse page 6-22). Here is the current situation: RADWIN 5000 HPMP User Manual Release 3.2.00 6-30...
  • Page 125 6. Repeat steps 1 to 3. Now the OK button is enabled: 7. Click OK. You are requested to accept your choice: 8. Click OK. Doing this, de-registers your defective device (10.101) and registers the replacement (10.102). RADWIN 5000 HPMP User Manual Release 3.2.00 6-31...
  • Page 126: Updating Hsu Services

    Choosing Update Services from an HSU context menu or clicking from the HSU button bar opens the following window: You may use this to switch the HSU between MIMO and Diversity mode and change the HSU time slot allocation. RADWIN 5000 HPMP User Manual Release 3.2.00 6-32...
  • Page 127: Suspending An Hsu

    Sector Band you must be logged on to the HBS as Installer. In Installer mode, the right hand button, on the Base Station button bar has an extra function, Change Band. RADWIN 5000 HPMP User Manual Release 3.2.00 6-33...
  • Page 128 Such additional Bands must be available within the framework of your local regula- tions • Acquisition of additional Bands may be subject to payment of a licensing fee to RAD- WIN Ltd. RADWIN 5000 HPMP User Manual Release 3.2.00 6-34...
  • Page 129: To Obtain/Install Additional Bands

    Chapter 6 The foregoing applies to both regulated and unregulated Bands. There is no connection between license fees payable to RADWIN for additional installed Bands (a hardware feature) and license fees payable to regulatory authorities for the right to use such Bands (a legal imposition).
  • Page 130 Key button. 6. The results of your request will be displayed with further instructions, A few minutes later, you should receive an email, containing in its body, a list of license keys. RADWIN 5000 HPMP User Manual Release 3.2.00 6-36...
  • Page 131: Configuration With Telnet

    For example, if you run Telnet as follows, telnet 192.168.10.200 you will be asked for a user name and password. The Telnet log on user name is the password that you used to enter the RADWIN Manager admin (for example, the default: ).
  • Page 132 ODU. A new Telnet session to the ODU may be opened after the reset is complete. help Displays the available commands Table 6-3: HBS Telnet - Set Commands requiring Reset Command Explanation set secId <SectorID> Set new sector ID - Reset required. RADWIN 5000 HPMP User Manual Release 3.2.00 6-38...
  • Page 133: Telnet Access To The Hsu

    ODU after the command completion set trap <index:1-10> <ipaddr> <port:0- Set a specific trap from the traps table (e.g. set trap 3 192.168..101 162) 65535> set readpw <oldpasswd> <passwd> Set the read access password (Read Community) RADWIN 5000 HPMP User Manual Release 3.2.00 6-39...
  • Page 134 ODU. A new Telnet session to the ODU may be opened after the reset is complete. help Displays the available commands Table 6-6: HSU Telnet - Set Commands requiring Reset Command Explanation set secId <SectorID> Set new sector ID - Reset required. RADWIN 5000 HPMP User Manual Release 3.2.00 6-40...
  • Page 135: Chapter 7 Direct Hsu Configuration

    Chapter Configuring an HSU Log on to the HSU either directly or over-the-air as shown in Chapter 4. For a registered HSU, you will see a display like this: RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 136 For an unregistered HSU, the throughput (T-put) fields and the Sector ID field would be empty. If the HBS is deactivated, or the HSU is stand-alone you will see a display like this: RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 137: Configuration Menu Buttons

    The Refresh button restores the current window to its previous state abandoning any changes you made, provided that you did not click Apply or OK. We will work through each of the Configuration tabs in turn: RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 138: System

    System Chapter 7 System Figure 7-3: HSU Configuration window (Direct) These items are convenience fields. They are typically entered before the sector is brought RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 139: Air Interface

    HSU, the Sector ID field will be blank and editable and the Channel Bandwidth field will be set to default and active: Figure 7-5: HSU Configuration - Air Interface for stand-alone HSU RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 140 Air Interface window: Figure 7-6: HSU Configuration - Air Interface Unregistered HSU Enter the Sector ID of the required HBS and click OK. The HSU should then “discover” the required HBS. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 141: Tx & Antenna

    Tx & Antenna Chapter 7 Tx & Antenna page 6-22. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 142: Management

    Management Chapter 7 Management page 6-23. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 143: Inventory

    Inventory Chapter 7 Inventory page 6-24. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 144: Security

    You may only change the SNMP community strings over a direct or over-the-air connection. You can change the Link Password for an un-synchronized HSU. Otherwise the functionality is the same as in page 6-25. RADWIN 5000 HPMP User Manual Release 3.2.00 7-10...
  • Page 145: Date & Time

    Date & Time Chapter 7 Date & Time page 6-26. RADWIN 5000 HPMP User Manual Release 3.2.00 7-11...
  • Page 146: Ethernet

    Ethernet Chapter 7 Ethernet This item is same for HSUs and the HBS. See page 6-16. RADWIN 5000 HPMP User Manual Release 3.2.00 7-12...
  • Page 147: Operations

    Operations Chapter 7 Operations page 6-28. RADWIN 5000 HPMP User Manual Release 3.2.00 7-13...
  • Page 148: Advanced

    You are logged on as Installer For this release, this feature for HSUs, is relevant to the 5.3 GHz ETSI and the 5.4 GHz FCC/ IC bands. Configuration of False Radar Mitigation is covered in Chapter RADWIN 5000 HPMP User Manual Release 3.2.00 7-14...
  • Page 149: Chapter 8 Monitoring And Diagnostics

    Chapter 8 Monitoring and Diagnostics The RADWIN Manager application enables you to monitor the sector, as well as perform basic diagnostic operations such as throughput testing. This chapter covers: • Retrieving link information • Throughput checking • Recent events •...
  • Page 150 Network performance data over defined time periods - - every 15 minutes for 30 days Spectrum Analysis For HBS, selected HSUs and general inter fence statistics for the sector  To get diagnostics: 1. Click the Get Diagnostics button: Figure 8-1: Get Diagnostics Dialog Box - HBS RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 151 Chapter 8 Figure 8-2: Get Diagnostics Dialog Box - HSU 2. Select or deselect the data options. If the file is to be sent to RADWIN Customer Sup- port leave all options checked. 3. HBS only: Choose HSUs to be included.
  • Page 152: Throughput Checking

    Get Diagnostics facility. Throughput Checking In this mode, RADWIN 5000 HPMP estimates Ethernet throughput by filling frames over the air to maximum for 30 seconds. This mode should not influence service. The test may be car- ried out for the HBS or an HSU.
  • Page 153: Recent Events

    The foregoing event types include events from all links for which this managing computer has been defined as the traps address. Only events from RADWIN equipment will be shown. Note Alarms (traps) are displayed in the Events Log in the lower panel of the main window. The Events Log may be saved as a text file.
  • Page 154 You may filter the events shown by choosing All or Internal. A full report may be seem by clicking Recent Events: Figure 8-3: Recent Events: Left- HBS, Center HSU from HBS, Right HSU direct In each case the report has the same format: RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 155: Performance Monitoring

    The left button may be used to save the report to a file. Performance Monitoring RADWIN 5000 HPMP Performance Monitoring constantly monitors traffic over the radio link and collects statistics data for the air interface and Ethernet ports. It does so continuously, even when the RADWIN Manager is not connected.
  • Page 156: Hbs

    Figure 8-5: Setting the upper traffic threshold To get data for display, click Get Data. The process may take a few seconds. Here is an extract Performance Monitoring report based on 15 minutes recording: RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 157 Data becomes invalidated following a reset. In the example below, the HBS was reset shortly after 11:00. All data prior to that time becomes invalidated. The only valid item is the first recording after re-sync. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 158: Hsu

    Here, only a downlink report is available. Otherwise the buttons have the same functionality as they do for the HBS. Here is an extract from a 15 minute report. We have broken it into three pieces so that it is legible: RADWIN 5000 HPMP User Manual Release 3.2.00 8-10...
  • Page 159 Figure 8-9: HSU - Performance Monitoring report - Both valid and invalid data (2 of 3) Figure 8-10: HSU - Performance Monitoring report - Both valid and invalid data (3 of 3) RADWIN 5000 HPMP User Manual Release 3.2.00 8-11...
  • Page 160: More On The Thresholds

    You can check the RSS from the Link Budget Calculator results during installation. Values of -5dB and -8dB from the current RSS are typical. TSL Threshold A counter is maintained, of the number of second intervals during which Tx power exceeds this threshold. RADWIN 5000 HPMP User Manual Release 3.2.00 8-12...
  • Page 161: Radwin Manager Traps

    The number of seconds count that received traffic exceeded this threshold. It can be used to measure traffic peaks. RADWIN Manager Traps The RADWIN Manager application issues traps to indicate various events, displayed in the Events Log. Table 8-4: RADWIN Manager Trap Messages...
  • Page 162: Active Alarms

    Other Diagnostic Aids Link Budget Calculator The Link Budget Calculator is part of the RADWIN Manager software and is found in the Help menu. This useful utility enables you to calculate the expected performance of the wireless link and the possible configurations for a specific link range including antenna size, cable loss and climate conditions.
  • Page 163: Online Help

    • Go to Start | Programs | RADWIN Manager | Link Budget Calculator Online Help Online help can be accessed from the Help menu on the main window of the RADWIN Man- ager. Using most common Web browsers, it may also be run going to...
  • Page 164: Part 4: Site Synchronization

    RADWIN 5000 HPMP Point to Multipoint Broadband Wireless USER MANUAL RELEASE 3.2.00 Part 4: Site Synchronization UM 5000-3200/08.11...
  • Page 165: What Is Hub Site Synchronization

    When several units are collocated at a common hub site, interference may occur from one unit to another. RADWIN ODU units support the collocation of more than two units at a cen- tral site. Like any other RF deployment, the wireless operation is highly dependent on factors such as available frequencies, the physical spacing between radios, other interfering radios, and whether WinLink 1000, RADWIN 2000 or RADWIN 5000 HPMP units are installed.
  • Page 166 The other collocated radios in the site - the HSS Clients, are connected to the HSS Master and synchronize their transmission to the pulses. An HSS Client can be configured to work in one of two modes: RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 167: Connecting An Hss Unit

    5. Repeat for all ODUs that are to be collocated at the hub site. The next ODU to be connected is inserted in SYNC 1, SYNC 2, followed by SYNC 3 and so on. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 168: Using A Single Hss Unit

    Condition 1: Cabling Sequence 1. Up to nine ODUs may be connected to the first HSS unit using HSS ports SYNC 1, SYNC 2, SYNC 3,... up to SYNC 9 in order without leaving empty ports. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 169 HSS units are populated in ascending order from SYNC 2. If an ODU is disconnected from an HSS unit, then all remaining ODUs must be moved up or down to maintain the connectivity. Note RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 170: Odu/Hss Unit Connection Pinout

    UNIT RJ-45 RJ-45 White/Green Green Not connected White/Orange Orange Blue White/Blue White/Brown Brown Radio Frame Pattern (RFP) A Radio Frame Pattern (RFP) is the cycle duration of transmit and receive of the air-frame. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 171: Without Hss

    The tables describe the efficiency of the air interface according to the RFP type, radio prod- ucts mix, services and channel bandwidth. The tables may also be viewed in the RADWIN Manager and in the Link Budget Calculator. The efficiency of the air interface will vary accord-...
  • Page 172: Rfp: General Radio Frame Pattern

    When setting the RPF, the following considerations should be borne in mind: • When synchronizing RADWIN 5000 HBS units you must use RFP E • When synchronizing RADWIN 5000 HBS with RADWIN 2000 or WinLink 1000 units you must use RFP E • RFP influences capacity and latency.
  • Page 173 Sector Configuration and HSS Chapter 9 Figure 9-10: HSS Settings window If you click the Enabled box, the central display (with Operational state opened) will look like this: RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 174 Continue Tx means that the HBS as a client to continue to work if there is no HSM pulse. If you select Hub Sync Master and click Apply, the display changes again: Figure 9-12: HBS as HSM RADWIN 5000 HPMP User Manual Release 3.2.00 9-10...
  • Page 175 Detected sync pulse Not detected ODU is independent Generating and detected HSM, but other HSM present RADWIN 5000 HBS is HSM, but Generating and detects a WinLink 1000 or Orange Improperly Detected RRADWIN 2000 HSM signal that is not RFP E...
  • Page 176: Figure

    The GSU receives a synchronization signal from the GPS once per second. It distributes a RADWIN proprietary synchronization signal to all other ODU units using the RS422 protocol and the standard HSS mechanism, where the GSU acts as an HSM unit.
  • Page 177: Figure

    10-3. This is an impossible situation, if all the links must send and receive together. It is further complicated by adding a third and further sites as shown. Figure 10-2: GSU Scenario - Communicating distributed sites RADWIN 5000 HPMP User Manual Release 3.2.00 10-2...
  • Page 178: Cascaded Sites Using Shifted Phase Transmission

    Figure 10-3: Phase shifted transmission - phase shift is 1/2 the RFD Choice of normal or shifted phase is configurable per GSU using the RADWIN Manager. GSU Redundancy The GSU is designed to support redundancy, improving the robustness of a GSU based topol- ogy.
  • Page 179: Gsu Kit Contents

    1 x GPS Antenna • 1 x GPS Antenna Mounting Kit • 1 x RF Cable, 1.5m • GSU Installation Overview The GSU uses the same container and cabling as a WinLink 1000 unit. RADWIN 5000 HPMP User Manual Release 3.2.00 10-4...
  • Page 180: Preparing The Gsu For Use

    Chapter 17 Chapter 18 of the use Manual apply to the GSU. It may be configured using the regular RADWIN Manager or Telnet. Preparing the GSU for Use Use the method of Chapter Preloading an ODU with an IP Address to change the IP address from the default (10.0.0.120).
  • Page 181 Installation or Configuration wizards. Such configuration as is necessary is car- ried out using a modified version of Site Configuration for WinLink 1000. Similarly, the Tool bar is a subset of that applicable to the WinLink 1000. RADWIN 5000 HPMP User Manual Release 3.2.00 10-6...
  • Page 182 Chapter 10 Using Site Configuration for the GSU Site Configuration: System Here is the opening window for Site Configuration: Figure 10-7: Site Configuration: System It is similar to that of the WinLink 1000. RADWIN 5000 HPMP User Manual Release 3.2.00 10-7...
  • Page 183 If the hub site consists only of WinLink 1000 units, then any suitable RFP may be chosen. If there are one or more RADWIN 2000 units, you must use RFP B or E. If there are one or more RADWIN 5000 HBS units, you must use RFP E.
  • Page 184 2. Setting the Tx Transmission Ratio Since the GSU is always HSM, it must be able to cater for hub site RADWIN 2000 C based links. (See the RADWIN 2000 User Manual, Chapter 5). If you use asymmetric allocation, shifted transmission phase becomes unavailable and you cannot “cascade”...
  • Page 185 Figure 10-9: Site Configuration: Management Here you set the GSU IP address, Subnet mask and gateway. You also set trap addresses here. It is identical to the corresponding panel for WinLink 1000. RADWIN 5000 HPMP User Manual Release 3.2.00 10-10...
  • Page 186 Configuring the GSU Chapter 10 Site Configuration: Inventory Figure 10-10: Site Configuration: Inventory Site Configuration: Security You can only change the SNMP Community stings: RADWIN 5000 HPMP User Manual Release 3.2.00 10-11...
  • Page 187 Configuring the GSU Chapter 10 Figure 10-11: Site Configuration: Security Site Configuration: Date and Time ODU Recent events, alarms and traps are time-stamped from the time method chosen here (NTP, managing computer, ODU default). RADWIN 5000 HPMP User Manual Release 3.2.00 10-12...
  • Page 188 Configuring the GSU Chapter 10 Figure 10-12: Setting the date and time for trap reporting Site Configuration: Operations The only available action here is Restore System Defaults: RADWIN 5000 HPMP User Manual Release 3.2.00 10-13...
  • Page 189 Configuring the GSU Chapter 10 Figure 10-13: Site Configuration: Operations RADWIN 5000 HPMP User Manual Release 3.2.00 10-14...
  • Page 190: Gsu Preferences

    The available commands are the same as for WinLink 1000 with the addition of four addi- tional display commands and three additional set commands. The additional display commands are display rfp RADWIN 5000 HPMP User Manual Release 3.2.00 10-15...
  • Page 191: Software Update For Gsus

    <ratio> [Leave as is] set tx_phase <mode:1=normal,2=shifted> [See above] Software Update for GSUs All GSUs in a distributed site can be updated simultaneously. Use an IP list as described in Chapter RADWIN 5000 HPMP User Manual Release 3.2.00 10-16...
  • Page 192 RADWIN 5000 HPMP Point to Multipoint Broadband Wireless USER MANUAL RELEASE 3.2.00 Part 5: Advanced Installation Topics UM 5000-3200/08.11...
  • Page 193: Software Upgrade

    Software Upgrade What is the Software Upgrade Utility? The RADWIN Manager provides a Software Upgrade Utility (SWU) to upgrade the software (firmware) of installed ODUs in a network. The update files may be located anywhere acces- sible by the operator.
  • Page 194: Upgrading An Installed Sector

    Figure 11-1: Software Upgrade Utility - Main window The default sites shown in the Software Upgrade list panel belong to the currently installed sector. The list may be empty if you are running the RADWIN Manager “offline”. 2. Click Add Site to add additional sites for upgrade.
  • Page 195 3. Having created an update list, click Upgrade Package to chose the relevant files. The default files are located in the SWU subdirectory in the RADWIN Manager instal- lation area. You may see one or more of the following SWU files:...
  • Page 196 Figure 11-5: Software upgrade in progress - Note the stop button Figure 11-6: Software upgrade completed successfully 9. Click Close to exit. 10. If you requested a delayed upgrade, a notice like this will appear in the SWU title bar: RADWIN 5000 HPMP User Manual Release 3.2.00 11-4...
  • Page 197 If you do not, following the next reset of Caution the updated site, you could experience a link software mismatch which may affect service. See page 9-3 for details. RADWIN 5000 HPMP User Manual Release 3.2.00 11-5...
  • Page 198: Radwin 5000 Hpmp Lbc

    RADWIN 5000 HPMP VLAN Tagging - Overview VLAN Terminology Both the technical literature and the RADWIN Manager use the terms VLAN ID and VID inter- changeably to denote a VLAN identification number. VLAN Background Information on the WEB The standards defining VLAN Tagging are IEEE_802.1Q and extensions.
  • Page 199: Qinq (Double Tagging) For Service Providers

    QinQ (Double Tagging) for Service Providers Chapter 12 Figure 12-1: VLAN scenarios handle by RADWIN 5000 HBS IEEE 802.1Q is used as the encapsulation protocol to implement this mechanism over Ether- net networks. QinQ (Double Tagging) for Service Providers QinQ is useful for Service Providers, allowing them to use VLANs internally in their “transport network”...
  • Page 200: Vlan Untagging

    VLAN functionality is supported at the MNG port of the HSU. The HSU MNG port can be configured to handle Ethernet frames at ingress direction (where frames enter the HSU) and at egress direction (where frame exit the HSU). RADWIN 5000 HPMP User Manual Release 3.2.00 12-3...
  • Page 201 Priority Code Point (PCP) which refers to the IEEE 802.1p priority. It indicates the frame priority level from 0 (lowest) to 7 (highest), which can be used to prioritize different classes of traffic (voice, video, data, etc). RADWIN 5000 HPMP User Manual Release 3.2.00 12-4...
  • Page 202: Vlan Configuration Using The Radwin Manager

    The facilities described below are offered as a service to enable you to get best value from your RADWIN 5000 HPMP links and are provided “as is”. Under no circumstances Disclaimer does RADWIN accept responsibility for network system or financial damages arising from incorrect use of these VLAN facilities.
  • Page 203: Configuration Of Vlan Tagging For Ethernet Service

    1. Right click an HSU on the HBS window, and then click Configure | Ethernet | VLAN Configuration. The VLAN Configuration window is displayed: In Disabled mode, Ethernet frames pass transparently over the radio links. 2. For Provider tagging, click the Provider Radio button: RADWIN 5000 HPMP User Manual Release 3.2.00 12-6...
  • Page 204 5. In Tag mode Ethernet frames are tagged or untagged to distinguish between differ- ent networks. 6. For completely transparent passage of tagged frames, there is nothing further to do. The following table shows the possible settings for each combination of Ingress and Egress modes: RADWIN 5000 HPMP User Manual Release 3.2.00 12-7...
  • Page 205 Allow up to 4 VIDs to be passed through Tag: Enter a VLAN Nothing further required Nothing further required Allow up to 4 VIDs to be passed through ID and Priority 7. Click OK. RADWIN 5000 HPMP User Manual Release 3.2.00 12-8...
  • Page 206 There are three types of radars: • Fixed: False radars with fixed pulse width having fixed repetition frequency • Variable: False radars with variable pulse width having variable repetition fre- quency RADWIN 5000 HPMP User Manual Release 3.2.00 13-1...
  • Page 207: Configuring False Radar Mitigation

    Figure 13-1: False Radar Mitigation 3. The DFS Frequency Status Table at the bottom of Figure 13-1 shows the time, type and frequency of the last radars detected. This table should be used to select the RADWIN 5000 HPMP User Manual Release 3.2.00 13-2...
  • Page 208: Fcc/Ic Considerations

    The FCC requires that devices installed within 35 km of any Terminal Doppler Weather Radars (TDWR) location should be registered in the voluntary WISPA sponsored database.For conve- nience, we supply guidelines about the way this is done in Chapter RADWIN 5000 HPMP User Manual Release 3.2.00 13-3...
  • Page 209: Fcc 5.4Ghz Device Registration

    Registering the Device  To register a device: 1. Enter the website http://www.spectrumbridge.com/udia/home.aspx and follow the instructions. At your first entry into the site, you will be required to register as a user: RADWIN 5000 HPMP User Manual Release 3.2.00 14-1...
  • Page 210 Registering the Device Chapter 14 2. Click the User Registration button to enter the registration page. RADWIN 5000 HPMP User Manual Release 3.2.00 14-2...
  • Page 211 Registering the Device Chapter 14 3. Fill in the registration page and click Register. 4. To complete device registration enter the Register Device tab as shown: RADWIN 5000 HPMP User Manual Release 3.2.00 14-3...
  • Page 212 Registering the Device Chapter 14 You are offered this: 5. Fill in the required information in the preceding web page and click the Register Device button. RADWIN 5000 HPMP User Manual Release 3.2.00 14-4...
  • Page 213: Tdwr Table

    W 074 16 13 N 40 35 37 5620 MHz PENNSAUKEN W 075 04 12 N 39 56 57 5610 MHz LAS VEGAS W 115 00 26 N 36 08 37 5645 MHz 1995 RADWIN 5000 HPMP User Manual Release 3.2.00 14-5...
  • Page 214 W 111 55 47 N 40 58 02 5610 MHz 4219 LEESBURG W 077 31 46 N 39 05 02 5605 MHz MILWAUKEE W 088 02 47 N 42 49 10 5603 MHz RADWIN 5000 HPMP User Manual Release 3.2.00 14-6...
  • Page 215: Quality Of Service

    QoS - Overview QoS is a technique for prioritization of network traffic packets during congestion. RADWIN 5000 HPMP sectors support two classification criteria, VLAN based or Diffserv based. You may chose which of them to use. Table 15-1: Default priorities an d allocation by VLAN ID and Diffserv...
  • Page 216: Setting Up The Hbs For Qos

    From the HBS manager, enter Configuration, open the Ethernet tab and then QoS configura- tion. QoS is disabled by default. You may chose between the VLAN (802.1p) and Diffserv methods. The default settings for Diffserv and VLAN are as shown in the next two figures: RADWIN 5000 HPMP User Manual Release 3.2.00 15-2...
  • Page 217: Setting Up An Hsu For Qos

    To configure an HSU for QoS: 1. Right click an HSU in the HBS manager HSU window, and choose Configuration. 2. Open the Ethernet tab and click QoS Configuration. The following window is dis- played: RADWIN 5000 HPMP User Manual Release 3.2.00 15-3...
  • Page 218 In particular, a queue set to zero weight will become nearly blocked under congestion with packets passing through on a best effort basis. 5. When you complete your entries, click OK to save them and continue. RADWIN 5000 HPMP User Manual Release 3.2.00 15-4...
  • Page 219 RADWIN 5000 HPMP Point to Multipoint Broadband Wireless USER MANUAL RELEASE 3.2.00 Part 6: Field Installation Topics UM 5000-3200/08.11...
  • Page 220: Figure 16-1 Large Clamp Figure 16-2 Small Clamp Figure 16-3 Arm

    16-2) Arm (see Figure 16-3) Screw hex head M8x40 Screw hex head M8x70 Washer flat M8 Washer spring M8 M8 Nuts Figure 16-1: Large Clamp Figure 16-2: Small Clamp Figure 16-3: Arm RADWIN 5000 HPMP User Manual Release 3.2.00 16-1...
  • Page 221: Figure 16-4 M

    Mounting an ODU on a Pole Chapter 16 Mounting an ODU on a Pole Figure 16-4: Mounting on a pole RADWIN 5000 HPMP User Manual Release 3.2.00 16-2...
  • Page 222: Figure 16-5 Mounting On A

    Mounting an ODU on a Wall Chapter 16 Mounting an ODU on a Wall Figure 16-5: Mounting on a Wall RADWIN 5000 HPMP User Manual Release 3.2.00 16-3...
  • Page 223: Figure 16-6 Mounted

    Optional external antennas can be mounted on a pole. The external mounting kit varies according to the specific antenna model. Mounting a Connectorized ODU Horizontally What follows applies to both WinLink 1000, RADWIN 2000 and RADWIN 5000 HPMP with obvious differences. An ODU may be mounted horizontally as shown in Figure 16-6.
  • Page 224: Grounding For Antenna Cable

    Warning This chapter is at best a guide. The actual degree of lightning protection required depends on local conditions and regulations. Note The RADWIN Lightning Protection System consists of the following components: • Grounding for the antenna coax cable •...
  • Page 225: Figure 17-1 G

    Grounding for Indoor/Outdoor Units ODU Grounding RADWIN Lightning Protection System uses a Shielded CAT 5e cable to interconnect the Out- door (ODU) and Indoor (IDU) units. However, this shielding does not provide a good lightning discharge path, since it can not tol- erate the high Lightning Current surges.
  • Page 226: Figure

    10 AWG. The grounding wire should be connected to a grounding rod or the building grounding system. The device should be permanently connected to ground. The RADWIN Lightning Protection Kit The RADWIN lightning protection kit contains the items as shown in Figure 17-2: Figure 17-2: RADWIN Lightning Protection Kit The lightning protector incorporates high-power gas discharge tube and current transistor protection in a single protector unit.
  • Page 227: Figure 17-3 G

    Using Lightning Protectors and Grounding Chapter 17 Figure 17-3: Grounding a typical pole installation RADWIN 5000 HPMP User Manual Release 3.2.00 17-4...
  • Page 228: Figure 17-4 G

    Using Lightning Protectors and Grounding Chapter 17 Figure 17-4: Grounding a typical wall installation The next figure shows a close-up of the rear of grounded ODU: RADWIN 5000 HPMP User Manual Release 3.2.00 17-5...
  • Page 229: Mounting Radwin Lighting Protection Unit

    5e cable at regular intervals up the mast. This may be as frequent as every 10 meters (33 feet). Note A second lightning protector Unit should be mounted at the building entry point and must be grounded, as shown in Figure 17-4 above. RADWIN 5000 HPMP User Manual Release 3.2.00 17-6...
  • Page 230: Figure 17-6 L

    Figure 17-6: Lightning protector and grounding at building entry point Internal ESD Protection circuits RADWIN equipment is designed to meet the ETSI/FCC/Aus/NZ/CSA EMC and Safety require- ments. To fulfill these requirements, the system's Telecom lines at the ODU/IDU are Trans- former-isolated and include internal ESD (Electro-Static-Discharge) Protection circuits.
  • Page 231: User Input

    Overview The Link Budget Calculator is a utility for calculating the expected performance of the RAD- WIN 5000 HPMP wireless link within a sector and the possible configurations for a specific link range. The utility allows you to calculate the expected RSS of the link, and find the type of services and their effective throughput as a function of the link range and deployment conditions.
  • Page 232: Expected Rss And Fade Margin

    The Service Availability calculation is based on the Vigants Barnett method which predicts the downtime probability based on a climate factor (C factor). Availability 7 –       – Cfactor frequency RequiredRange – ExpectedFadeM ------------------------------------------------------------  RADWIN 5000 HPMP User Manual Release 3.2.00 18-2...
  • Page 233: Antenna Height

    The Fresnel zone (pronounced "frA-nel", with a silent “s”) is an elliptically shaped conical zone of electromagnetic energy that propagates from the transmitting antenna to the receiving antenna. It is always widest in the middle of the path between the two antennas. RADWIN 5000 HPMP User Manual Release 3.2.00 18-3...
  • Page 234: Figure 18-1 Fresnel Zone

    The top of the obstruction does not extend far into the Fresnel zone, leaving 60% of the Fresnel zone clear; therefore, the signal is not significantly attenuated. For more about Fresnel zone, see http://en.wikipedia.org/wiki/Fresnel_zone. RADWIN 5000 HPMP User Manual Release 3.2.00 18-4...
  • Page 235: Figure 18-3 Linkb

    Running the Link Budget Calculator Chapter 18 Running the Link Budget Calculator The Link Budget Calculator is supplied on the RADWIN Manager CD. It may be run stand- alone from the CD or from the RADWIN Manager application.  To run the Link Budget Calculator from the CD: 1.
  • Page 236 • Click the yellow bar and follow the instructions to allow blocked con- tent.  To use the Link Budget Calculator for RADWIN 5000 HPMP: 1. Click the RADWIN 5000 HPMP tab. Figure 18-4: RADWIN 5000 HPMP LBC main window 2.
  • Page 237: Figure 18-5 Band Selector

    5. If the required range between the two link sites is known, you may enter it directly. Alternatively, you may enter the latitude and longitude of each site in the link, in which case the distance between them will be calculated and displayed. RADWIN 5000 HPMP User Manual Release 3.2.00 18-7...
  • Page 238: Figure 18-6 C

    Figure 18-6: Calculation of distance from site coordinates If for example, we enter: Site A: 41.1°N lat 74.2°W Long Site B: 40.8°N lat 74.0°W Long and press Set, the range will be calculated and displayed: RADWIN 5000 HPMP User Manual Release 3.2.00 18-8...
  • Page 239: Figure 18-7 Climactic

    C Factor values. It is only available if you choose a non-adaptive rate. Figure 18-7: Climactic C Factors For help about what these mean, click the ? button to the right of the list in Figure 18-7. RADWIN 5000 HPMP User Manual Release 3.2.00 18-9...
  • Page 240: Figure 18-8 Climactic

    Running the Link Budget Calculator Chapter 18 Figure 18-8: Climactic C Factor description Figure 18-9 we display a map of the world showing C Factor contours: Figure 18-9: World map showing C Factor contours RADWIN 5000 HPMP User Manual Release 3.2.00 18-10...
  • Page 241 Figure 18-10: LBC - Results section The Expected Performance parameters are calculated and displayed: • Expected RSS - the expected RSS that the RADWIN Manager shows when the RAD- WIN 5000 HPMP ODUs are optimally aligned • Services Type - max number of T1 or E1 trunks if “Max Trunks” is selected •...
  • Page 242: What Is Spectrum View

    The Spectrum View reports may be generated as images, CSV files or text files as part of the Get Diagnostics feature. All of these are intended for use by to RADWIN customer Services to assist with diagnosing interference related problems.
  • Page 243: Where Is The Spectrum View Data Stored

    . The Spectrum View main window opens in full screen mode: Use the top left panel to set the Spectrum View configuration parameters and choose an anal- ysis type - Entire Sector or Specific HSU. RADWIN 5000 HPMP User Manual Release 3.2.00 19-2...
  • Page 244 Since a large sector will clutter up the right hand display area, you may selectively Show, min- imize or remove a sector member. Another way of freeing up more space for analysis displays is to hide the left hand panel using the circled arrow: RADWIN 5000 HPMP User Manual Release 3.2.00 19-3...
  • Page 245: Figure 19-1 Spectrumv

    Figure 19-1: Spectrum View data panel for the HBS, ready for data The standard X button closes the window completely (but does not loose data). The - button collapses the view to look like this: RADWIN 5000 HPMP User Manual Release 3.2.00 19-4...
  • Page 246: Spectrum View Display Function Buttons

    Each button function applies to all of the sector members at once. Note Table 19-1: Spectrum View Analysis Display Buttons functionality Button Purpose Show/Hide Antenna A Show/Hide Antenna B Show/Hide average Show/Hide current channel (HSUs only) Show/Hide maximum RADWIN 5000 HPMP User Manual Release 3.2.00 19-5...
  • Page 247: Running Spectrum View From The Hbs

    If it is acceptable to drop the service click Yes. The processing may appear to have stopped - but it is not complete until all of the Show buttons for selected HSUs are enabled. Here is the result for the HBS: RADWIN 5000 HPMP User Manual Release 3.2.00 19-6...
  • Page 248: Figure 19-2 Spectrumv

    (circled) to the upper left of either graph. Clicking it opens a Windows File-Save dialog allowing you to save the graph to disk as a jpg file. Here is the analysis for one of the HSUs. It is a bit different: RADWIN 5000 HPMP User Manual Release 3.2.00 19-7...
  • Page 249: Running Spectrum View From An Hsu

    HBS. There is a major difference between running Spectrum View on an active HSU (registered or not) or in total isolation from the sector. Here is what happens in total isolation: RADWIN 5000 HPMP User Manual Release 3.2.00 19-8...
  • Page 250 Now we return the HSU to the sector: Figure 19-4: HSU spectrum analysis within the sector The hump in Figure 19-4 reflects the duty cycle signal from the HBS centered on the current channel (barely seen but circled). RADWIN 5000 HPMP User Manual Release 3.2.00 19-9...
  • Page 251: Using The Web Interface

    The WI is a tool for technicians to “quick-install” a HSU in a link with minimum effort. It may also be employed by a user for a quick look at current operating parameters and the Recent Events logs. RADWIN 5000 HPMP User Manual Release 3.2.00 20-1...
  • Page 252: How It Works

    The WI is a developing technology. It is possible that the current distributed release may have additional or slightly different features from those shown here. The description below, should nevertheless give you a good idea of how to use the WI. RADWIN 5000 HPMP User Manual Release 3.2.00 20-2...
  • Page 253: Technical Background

    ODUs. The WI can be used directly opposite the HBS any of its HSUs. It can also be used over the air from the HBS to any registered HSU. The WI is available for RADWIN 2000 C and RADWIN 2000 B ODUs at release level 2.6.00 or later along with RADWIN 5000 HPMP ODUs, this release and later.
  • Page 254: Figure 20-1 Web Interface

    The User Name and Password are respectively, as used for Telnet access. You must click the Log In button to effect entry to the WI. The foregoing applies to both the HBS and the HSUs. RADWIN 5000 HPMP User Manual Release 3.2.00 20-4...
  • Page 255: Figure 20-2 Web Interface

    The bottom panel shows all member HSUs. The green LED icons will change color to reflect the status of HSUs. For example, deregistering an HSU will change it to black as in the RAD- WIN Manager. RADWIN 5000 HPMP User Manual Release 3.2.00 20-5...
  • Page 256 Configure Chapter 20 Figure 20-4: HSU Haydn deregistered Now, click anywhere on the HBS Info panel: Configure The Configure button opens the following display: RADWIN 5000 HPMP User Manual Release 3.2.00 20-6...
  • Page 257 There is nothing that can be changed on this panel. Clicking the Antenna & Tx Power button opens up the following window: The only item that can be changed is the Antenna Type: Inventory The Inventory display is for information only. RADWIN 5000 HPMP User Manual Release 3.2.00 20-7...
  • Page 258 Configure Chapter 20 Changing Antenna Type will call a sector-wide sync loss. Caution Management The Management fields are all fully editable: RADWIN 5000 HPMP User Manual Release 3.2.00 20-8...
  • Page 259 Configure Chapter 20 If you change any of these fields, you will cause an HBS reset: RADWIN 5000 HPMP User Manual Release 3.2.00 20-9...
  • Page 260 Configure Chapter 20 Other You may change the HBS LAN port configuration: You will receive the following notification: RADWIN 5000 HPMP User Manual Release 3.2.00 20-10...
  • Page 261: Hsu Management

    HSU configuration is accomplished by clicking the required HSU in the bottom panel of Chap- 20. For the purposes of this section, we have deregistered Haydn so the panel looks like this: RADWIN 5000 HPMP User Manual Release 3.2.00 20-11...
  • Page 262 The Main Window Chapter 20 Click Mozart. Here is what you see: Clicking Configure, opens up a new tab in you browser, pointing to Mozart: RADWIN 5000 HPMP User Manual Release 3.2.00 20-12...
  • Page 263 HBS. Here is the Configure display: The only fucction here, which differs from the corresponding HBS function, is the Air Inter- face tab. RADWIN 5000 HPMP User Manual Release 3.2.00 20-13...
  • Page 264 “loose” it from the sector. The only remedy is to log on to the HSU with a direct connection and either reverse the above process, or log on as Installer and using the regular Change Band. RADWIN 5000 HPMP User Manual Release 3.2.00 20-14...
  • Page 265: Part 7: Product Reference

    Product Reference RADWIN 5000 HPMP Point to Multipoint Broadband Wireless USER MANUAL RELEASE 3.2.00 Part 7: Product Reference UM 5000-3200/08.11...
  • Page 266: Technical Specifications

    The latest authoritative and most up to date technical specifications are available as Data Sheets obtainable from RADWIN Customer Service. In any event, RADWIN reserves the right to change these specifications without notice. ODU - HBS and HSU...
  • Page 267 ODU: Outdoor Unit with Integrated Antenna, Connectorized for External Antenna or Embedded Architecture PoE device for Ethernet only HBS: • Outdoor RADWIN CAT-5e cable. maximum cable length: 100m for 10/ 100BaseT. ODU to PoE Interface • Outdoor RADWIN CAT-5e cable. maximum cable length: 75m for 1000BaseT.
  • Page 268 GbE PoE Device - Indoor, AC for HBS only Appendix A Management Application (per sector) RADWIN Manager Protocol SNMP and Telnet RADWIN NMS - RNMS Operating Temperatures HBS/HSU: -35°C to +60°C / -31°F to +140°F Humidity HBS/HSU: Up to 100% non-condensing, IP67 FCC/IC (cTUVus) UL 60950-1, UL 60950-22, CAN/CSA C22.2 60950-1, CAN/CSA C22.2 60950-22...
  • Page 269 Outdoor CAT-5e; Maximum cable length: 100m for 10/100BaseT Standard socket IEC320 C14 type ODU (PoE Port) RJ-45 connector Case Plastic Dimensions 16cm(W) x 6.3cm(D) x 3.33cm(H) Weight 250g Operating Temperatures 0°C - 40°C Humidity 90% non-condensing RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 270 IEC 60721-3-4 Class 4M5 Standards IP67 FCC/IEC/ CAN/CSA Designed to meet 60950-1, 60950-22 ETSI Designed to meet EN 300 386 V1.3.2; EN 301 489-1 V1.4.1 Designed to meet CFR47 Class B, Part15, Subpart B RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 271: Antenna Characteristics

    These factors are limited by country regulations. The RADWIN 5000 HPMP may be operated with an integrated antenna attached to the HSU unit, or with an external antenna wired to the HBS/HSU via a N-type connectors. All cables and connections must be connected correctly to reduce losses.
  • Page 272: Wiring Specifications

    Power (+) Blue Power (+) White/Blue Power () White/Brown Power () Brown HBS/HSS Unit Connection Pinout Table B-2: HBS/HSS Unit Connection Pinout Color UNIT RJ- RJ-45 White/Green Green Not connected White/Orange Orange Blue White/Blue RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 273: User Port Connectors

    Transmit Data (positive) TD (+) Transmit Data (negative) TD (–) Receive Data (positive) RD (+) Receive Data (negative) RD (–) DC Power Terminals DC PoE Table B-4: Terminal Block 2-pin -48VDC Function Right – Left RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 274: Control Method

    Interface API Control Method The RADWIN Manager application provides all the means to configure and monitor a RADWIN 5000 HPMP link, communicating with the SNMP agent in each ODU. Each SNMP agent con- RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 275: Community String

    To control a link, all SNMP requests should go to the local site IP address. Table 4-3 for default Community strings. Private MIB Structure The sections in the private RADWIN MIB and its location in the MIB tree are shown in Figure C-1 below: Figure C-1: Top Level Sections of the private MIB...
  • Page 276: Mib Parameters

    .1.3.6.1.2.1.2.2.1.3 Integer The type of interface, distinguished according to the physical/link protocol(s) immediately `below' the network layer in the protocol stack. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 277 The total number of packets that higher-level protocols requested be transmitted to a non- unicast (i.e., a Subnetwork-broadcast or Subnetwork-multicast) address, including those that were discarded or not sent. a. x is the interface ID RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 278 RW Read/Write Community String. This parameter always returns ***** when retrieving its value. It is used by the Manager application to change the Read/Write Community String. The SNMP agent accepts only encrypted values. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 279 } winlink1000OduSrvRingVlanIdIndex Index of VLAN ID of the internal ring messages. winlink1000OduSrvRingVlanId RW VLAN ID of the internal ring messages. Valid values are 1 to 4094. Initial value is 0 meaning VLAN unaware. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 280 RW Failure action of the interface. winlink1000OduEthernetNumOfPorts 1.3.6.1.4.1.4458.1000.1.3.3 Integer Number of ODU network interfaces. winlink1000OduEthernetGbeSupported 1.3.6.1.4.1.4458.1000.1.3.4 Integer An indication of the vaildity of the channel's data. If the channel was scanned the data is valid, else not. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 281 For Channel Bandwidth of 20 10 5 MHz divide the value by 1 2 4 respectively. winlink1000OduAirCurrentRateIdx 1.3.6.1.4.1.4458.1000.1.5.9.5 Integer Index of current air rate. winlink1000OduAirTxPower36 1.3.6.1.4.1.4458.1000.1.5.10 Integer RW Deprecated parameter. Actual behavior is read- only. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 282 Integer RW Channel bandwidth in KHz. A change is effective after reset. winlink1000OduAirChannelBWTable N/A Channel Bandwidths table. winlink1000OduAirChannelBWEntry N/A Channel Bandwidth table entry. INDEX { winlink1000OduAirChannelBWIndex } winlink1000OduAirChannelBWIndex 1.3.6.1.4.1.4458.1000.1.5.25.1.1 Integer Channel Bandwidth index. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 283 N/A ODU Radio Frame Patterns (RFP) Table. winlink1000OduAirHssRfpEntry N/A ODU RFP Table entry. INDEX { winlink1000OduAirHssRfpIndex } winlink1000OduAirHssRfpIndex 1.3.6.1.4.1.4458.1000.1.5.40.7.1.1 Integer ODU RFP Table index. The index represent the Radio Frame Pattern: typeA(2) typeB(3) typeC(4) typeD(5) typeE(6). RADWIN 5000 HPMP User Manual Release 3.2.00 C-10...
  • Page 284 Maximum allowed Antenna Gain in 0.1 dBi resolution. winlink1000OduAirMinAntennaGain 1.3.6.1.4.1.4458.1000.1.5.45 Integer Minimum allowed Antenna Gain in 0.1 dBi resolution. winlink1000OduAirMaxEIRP 1.3.6.1.4.1.4458.1000.1.5.46 Integer Maximum EIRP value as defined by regulation in 0.1 dBm resolution. RADWIN 5000 HPMP User Manual Release 3.2.00 C-11...
  • Page 285 1.3.6.1.4.1.4458.1000.1.5.56.5.1.4 TimeTicks Channel last scan timestamp in hundredths of a Timestamp second since device up time. If the channel was not scanned than the return value will be 0. RADWIN 5000 HPMP User Manual Release 3.2.00 C-12...
  • Page 286 The latter lasts no more than a predetermined interval (default 30 sec). winlink1000OduAirDesiredNetMasterTxRatio 1.3.6.1.4.1.4458.1000.1.5.60.1 Integer RW This parameter is reserved to the element manager provided with the product. winlink1000OduAirCurrentNetMasterTxRatio 1.3.6.1.4.1.4458.1000.1.5.60.2 Integer Represents the actual Net Master Tx RAtio. RADWIN 5000 HPMP User Manual Release 3.2.00 C-13...
  • Page 287 TxMBytes (4) EthCapacityThreshUnder (4) HighTrafficThreshExceed (4) Compressed Etherent ODU interface (size in brackets): (4) ES (4) SES (4) BBE (4) Integrity (1) RxMBytes (4) TxMBytes (4) EthCapacityThreshUnder (4) HighTrafficThreshExceed (4) ActiveSeconds (4) RADWIN 5000 HPMP User Manual Release 3.2.00 C-14...
  • Page 288 Current number of Severely Errored Seconds per interval of 24 hours. winlink1000OduPerfMonDayBBE Current number of Background Block Errors per interval of 24 hours. winlink1000OduPerfMonDayIntegrity Indicates the integrity of the entry per interval of 24 hours. RADWIN 5000 HPMP User Manual Release 3.2.00 C-15...
  • Page 289 Number of seconds Receive Signal Level 2Exceed exceeded the RSL2 threshold ACCESS read- only per interval. winlink1000OduPerfMonAirIntervalMinTSL Current Min Transmit Signal Level per interval. winlink1000OduPerfMonAirIntervalMaxTSL Current Max Transmit Signal Level per interval. RADWIN 5000 HPMP User Manual Release 3.2.00 C-16...
  • Page 290 The number of times actual traffic was above ThreshExceed threshold in the each interval. winlink1000OduPerfMonEthIntervalActiveSeco The number of seconds in which RPL Ethernet service was not blocked in the each interval. RADWIN 5000 HPMP User Manual Release 3.2.00 C-17...
  • Page 291 RW When the RX power exceeds this threshold a performance monitoring RSL2 counter is incremented. winlink1000OduPerfMonBBERThresh1 1.3.6.1.4.1.4458.1000.1.6.23 Integer RW When the BBER exceeds this threshold a performance monitoring BBER counter is incremented. The units are 1/10 of a percent. RADWIN 5000 HPMP User Manual Release 3.2.00 C-18...
  • Page 292 Timestamp of this alarm. This number is in seconds from Midnight January 1st 1970. winlink1000OduAgnCurrAlarmText Alarm display text (same as the text in the sent trap). winlink1000OduAgnLastEventsNumber 1.3.6.1.4.1.4458.1000.1.7.4.1 Integer This counter indicates the size of the winlink1000OduAgnLastEventsTable RADWIN 5000 HPMP User Manual Release 3.2.00 C-19...
  • Page 293 RW VLAN untagged VIDs for Sfp port winlink1000IduAdmVlanLan1FilteredVIDs RW VLAN filtered VIDs for LAN1 port winlink1000IduAdmVlanLan2FilteredVIDs RW VLAN filtered VIDs for LAN2 port winlink1000IduAdmVlanSfpFilteredVIDs RW VLAN filtered VIDs for Sfp port RADWIN 5000 HPMP User Manual Release 3.2.00 C-20...
  • Page 294 Cost of the TDM Service in bps. winlink1000IduSrvAvailServicesTable N/A ODU Possible TDM Services table. winlink1000IduSrvAvailServicesEntry N/A ODU TDM Services table entry. INDEX { winlink1000IduSrvAvailServicesIndex } winlink1000IduSrvAvailServicesIndex Table index. The index is the bit mask of the TDM service. RADWIN 5000 HPMP User Manual Release 3.2.00 C-21...
  • Page 295 5 = Local Internal bit 6 = Remote Internal winlink1000IduTdmTxClockDesiredState RW Required state of the TDM Transmit Clock Control. A change is effective after re-activation of the TDM service. winlink1000IduTdmTxClockActualState Actual state of the TDM Transmit Clock Control. RADWIN 5000 HPMP User Manual Release 3.2.00 C-22...
  • Page 296 N/A IDU TDM Links Statistics table entry. INDEX { winlink1000IduTdmBackupIndex } winlink1000IduTdmBackupIndex Table index. winlink1000IduTdmBackupMode RW TDM backup mode: Enable or Disable where the main link is the air link or the external link. Changes will be effective immediatly. RADWIN 5000 HPMP User Manual Release 3.2.00 C-23...
  • Page 297 RW Downlink MIR towards specific HSU in units of kbps. winlink1000HbsAirConfHsuName 1.3.6.1.4.1.4458.1000.3.1.6.2.1.4 DisplayString RW HSU name. winlink1000HbsAirConfHsuLocation 1.3.6.1.4.1.4458.1000.3.1.6.2.1.5 DisplayString RW HSU location. winlink1000HbsAirConfDualAntTxMode 1.3.6.1.4.1.4458.1000.3.1.6.2.1.6 Integer RW Spatial multiplexing: MIMO (1) or Diversity (2) RADWIN 5000 HPMP User Manual Release 3.2.00 C-24...
  • Page 298 (32 bytes) HSU Serial number (16 bytes) MAC Address (12 bytes) Air Link Range Max Throughput Down (4 bytes) Max Throughput Up. (4 bytes) Cpacity Limit (4 bytes) HSU Antenna type (1 byte) RADWIN 5000 HPMP User Manual Release 3.2.00 C-25...
  • Page 299 1.3.6.1.4.1.4458.1000.3.3.2.1.1.6 Integer RW The Vlan mode in the Ingress direction winlink1000OduServiceVlanTblEgressFilter1 1.3.6.1.4.1.4458.1000.3.3.2.1.1.7 Integer RW VLAN Filter1 VID winlink1000OduServiceVlanTblEgressFilter2 1.3.6.1.4.1.4458.1000.3.3.2.1.1.8 Integer RW VLAN Filter2 VID winlink1000OduServiceVlanTblEgressFilter3 1.3.6.1.4.1.4458.1000.3.3.2.1.1.9 Integer RW VLAN Filter3 VID RADWIN 5000 HPMP User Manual Release 3.2.00 C-26...
  • Page 300 15 minutes period. Relevant for point to point systems. winlink1000HbsPerfMonAirGenCurrHighTraffic 1.3.6.1.4.1.4458.1000.3.4.2.1.4 Gauge The number of times actual traffic was above ThreshExceed threshold in the present 15 minutes period. RADWIN 5000 HPMP User Manual Release 3.2.00 C-27...
  • Page 301 (4 bytes) Tx Rate In Kbps of the whole sector (4 bytes) Rx Rate In Fps of the whole sector (4 bytes) Tx Rate In Fps of the whole sector (4 bytes) RADWIN 5000 HPMP User Manual Release 3.2.00 C-28...
  • Page 302: Mib Traps

    Community string or by the trap description text. Each trap contains a trap description and additional relevant information such as alarm sever- ity, interface index, time stamp and additional parameters. RADWIN 5000 HPMP User Manual Release 3.2.00 C-29...
  • Page 303: Trap Parameters

    Indicates that the ODU recovered from an error but there are configuration changes. Contains two parameters: 1 - Description: Configuration changed. Error code is: %n. 2 - %n number. RADWIN 5000 HPMP User Manual Release 3.2.00 C-30...
  • Page 304 %n 2 - %n number lanPort1DisconnectedAlarm major Indicates the LAN port 1 status changed to disconnected.Contains a single parameter which is its description: 1 - Description: LAN port 1 status changed to disconnected. RADWIN 5000 HPMP User Manual Release 3.2.00 C-31...
  • Page 305 %n0 MHz and the other is %n1 MHz. %n0 is the local Channel Bandwidth value in MHz. %n1 is the remoet Channel Bandwidth value in MHz. gpsNotSynchronized major Indicates that the GPS is not synchronized with satellites. Pulses are self generated. RADWIN 5000 HPMP User Manual Release 3.2.00 C-32...
  • Page 306 1 - Description: Software Versions compatible hssMultipleSourcesDisappearedClear normal Indicates that multiple sync pulse sources disappeared. Contains a single parameter which is its description: 1 - Description: HSS multiple sync pulse sources disappeared. RADWIN 5000 HPMP User Manual Release 3.2.00 C-33...
  • Page 307 RADWIN Manager Traps The RADWIN Manager application issues traps to indicate various events. These traps are shown in the RADWIN Managerr Events Log. A list of Trap Messages as displayed by the RADWIN Manager is shown in Table 8-4. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 308 The antennas used for the following transmitters must be installed so as to provide a mini- mum separation distance from bystanders as specified in the following tables: Table D-1: Safety Distances for RADWIN 5000 HPMP FCC and IC Products Frequency Antenna Min.
  • Page 309 RF Exposure Appendix D RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 310: Dual Antennas At The Hbs And An Hsu

    About Single and Dual Antennas Each RADWIN 5000 HPMP ODU is made of two radio transceivers (radios). The radios make use of algorithms that utilize both MIMO and Diversity resulting in enhanced capacity, range and link availability. The number of antennas (i.e. radios) used is determined by user configu- ration and by automatic system decisions, explained below.
  • Page 311: Single Antennas At Both Sites

    Appendix E Upon selecting Antenna Type as Dual, RADWIN 5000 HPMP automatically selects MIMO mode and doubles the air rates. RADWIN Manager indicates a case of unbalanced RSS between the two antennas in the HBS panels. Diversity Mode Diversity Mode uses two antennas to improve the quality and reliability of the link. Often, there is not a clear line-of-sight (LOS) between transmitter and receiver.
  • Page 312 Diversity 25 Mbps 25 Mbps 25 Mbps 25 Mbps Site A and B may be HBS or HSU. The rates used by RADWIN 5000 HPMP are shown in Table E-2 below: Table E-2: RADWIN 5000 HPMP Air rates Air-Rate Antenna...
  • Page 313 Required Tx Power (per radio) will be adjusted down to the lesser of the value entered and maxAvailableTxPower • Tx Power (system) is maxAvailableTxPower + 3 (for 2 radios) • Max EIRP is maxRegEIRP. • EIRP is maxAvailableTx Power + Antenna Gain - Cable Loss RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 314: Mise À La Terre

    éléments sous tension. Mise à la terre Tous les produits RADWIN doivent être mis à la terre pendant l'usage courant. La mise à la terre est assurée en reliant la fiche d'alimentation à une prise de courant avec une protection de terre.
  • Page 315: Précautions De Sécurité Pendant Le Montage De Odu

    Connecter un câble de terre de 18 AWG à la borne de masse de l'appareil. L'appareil doit être constamment connecté à la terre. Installation sur pylône et mur L' ODU ou l'O-PoE peuvent être montés sur un pylône ou un mur. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 316: Figure F-3 Bras

    M8x70 • quatre rondelles plates M8 • trois rondelles élastiques M8 • deux écrous M8. Figure F-1: Figure F-2: Figure F-3: grande clame petite clame bras Montage sur un pylône RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 317 Montage sur un pylône Appendix F Figure F-4: Montage sur un pylône RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 318: Figure F-5 Montage Sur Un Mur

    Montage sur un mur Appendix F Montage sur un mur Figure F-5: Montage sur un mur RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 319: Montage D'une Antenne Externe

    3. Passer les deux courroies de fixation par les fentes verticales dans le support à pivot- ement. 4. Attacher l'antenne au pylône en utilisant les deux courroies de fixation . Ajuster l'inclinaison nécessaire en utilisant l'échelle angulaire et serrer tous les boulons et écrous à la position requise. RADWIN 5000 HPMP User Manual Release 3.2.00...
  • Page 320 Manage, Detail Panel button bar functions 4- manager, HSUs Panel 4-12 Manager, main window Events package contents Package, contents of Hardware Installation ODU/HSS Connection Pinout Radio Frame Pattern Table RADWIN 5000 HPMP User Manual Release 3.2.00 Index 1...
  • Page 321 Unsupported Device Internal ESD Protection circuits 17-7 Login showing Community Options Login showing user types Manager Software 15-1 Link Budget Calculator, see LBC Overview 15-1 Link Site setting up, ff 15-1 Survey RADWIN 5000 HPMP User Manual Release3.2.00 Index 2...
  • Page 322 Ethernet Thresholds - Capacity 8-13 Ethernet Thresholds - Traffic 8-13 RSL Threshold 8-12 TSL THreshold 8-12 Performance monitoring Manager, Base Station Panel Manager, Status Panel Managing from HBS Software Upgarde Multiple sites 11-3 Single Site 11-2 RADWIN 5000 HPMP User Manual Release3.2.00 Index 3...

Table of Contents

Save PDF