Advertisement

Private MIB Parameters
Table C‐3: Private MIB Parameters ‐ HSU (Sheet 23 of 33)
Name
winlink1000IduSrvEthThroughput
winlink1000IduSrvEthMaxInfoRate
winlink1000IduSrvAvailableTrunksT
1
winlink1000IduEthernetIfTable
winlink1000IduEthernetIfEntry
winlink1000IduEthernetIfIndex
winlink1000IduEthernetIfAddress
winlink1000IduEthernetNumOfLan
Ports
winlink1000IduEthernetNumOfSfpP
orts
winlink1000IduEthernetSfpProperti
es
winlink1000IduEthernetGbeSuppor
ted
winlink1000IduEthernetOduInError
s
winlink1000IduBridgeTpAging
winlink1000IduTdmTxClockAvailStat
es
winlink1000IduTdmTxClockDesiredS
tate
winlink1000IduTdmTxClockActualSt
ate
winlink1000IduTdmMasterClockAva
ilOptions
winlink1000IduTdmMasterClockDes
ired
winlink1000IduTdmMasterClockAct
ual
winlink1000IduTdmConfigTable
RADWIN 5000 HPMP User Manual
OID
Type
Release 3.5.70
Description
RO
Current available Ethernet service throughput in 
bps. 
RW Holds the maximum bandwidth (kbps) to be 
allocated for Ethernet service.    Value of zero 
means that Ethernet service works as best 
effort.    The maximum value is product specific. 
Refer to the user manual. 
RO
A bitmap describing the TDM trunks that can be 
opened under T1 configuration.    The values 
take into account the IDU hardware 
configuration  the air rate and the installation 
range. 
N/A IDU Ethernet Interface table. 
N/A IDU Ethernet Interface table entry.   INDEX { 
winlink1000IduEthernetIfIndex } 
RO
If Index corresponding to this Interface. 
RO
IDU MAC address. 
RO
Number of LAN interfaces in the IDU. 
RO
The number of SFP interfaces in the IDU. 
RO
SFP venfor properties : Vendor Name  PN and 
Revision. 
Supported Giga bit Ethernet in IDU.
RO
The number of inbound packets that contained 
errors preventing them from being deliverable 
to a higher‐layer protocol. 
RW Timeout in seconds for aging. Note that for this 
parameter to be effective    the ODU must be 
configured to HUB mode. A change is effective 
immediately. 
RO
Available states of the TDM Transmit Clock 
Control  each input status is represented by a 
bit.   When the state is available  the bit value is 
1. When the state is unavailable  the bit    value 
is 0.   The available states are:     bit 2 = 
Transparent   bit 3 = Local Loop Timed   bit 4 = 
Remote Loop Timed   bit 5 = Local Internal   bit 6 
= Remote Internal 
RW Required state of the TDM Transmit Clock 
Control. A change is effective after re‐activation 
of the TDM service. 
RO
Actual state of the TDM Transmit Clock Control. 
RO
Available options of the TDM Master Clock 
Control  each input status is represented by a 
bit.   When the option is available  the bit value 
is 1. When the option is unavailable  the bit 
value is 0.   The available options are:     bit 2 = 
Automatic   bit 3 = Trunk #1   bit 4 = Trunk #2   bit 
5 = Trunk #3   bit 6 = Trunk #4   When no options 
are available the returned value is: 1 
RW Required TDM Master Clock. A change is 
effective after re‐activation of the TDM service. 
RO
Actual Trunk used for TDM Master Clock. 
N/A IDU TDM Links Configuration table. 
C‐61