Private MIB Parameters
Table C‐3: Private MIB Parameters ‐ HSU (Sheet 8 of 33)
Name
winlink1000OduAirLinkWorkingMo
de
winlink1000OduAirMajorLinkIfVersi
on
winlink1000OduAirMinorLinkIfVersi
on
winlink1000OduAirHssDesiredOpSt
ate
winlink1000OduAirHssCurrentOpSt
ate
winlink1000OduAirHssSyncStatus
winlink1000OduAirHssExtPulseStat
us
winlink1000OduAirHssExtPulseType 1.3.6.1.4.1.4458.1000.1.5.4
winlink1000OduAirHssDesiredExtPu
lseType
winlink1000OduAirHssRfpTable
winlink1000OduAirHssRfpEntry
winlink1000OduAirHssRfpIndex
winlink1000OduAirHssRfpEthChann
elBW5MHz
winlink1000OduAirHssRfpTdmChan
nelBW5MHz
winlink1000OduAirHssRfpEthChann
elBW10MHz
winlink1000OduAirHssRfpTdmChan
nelBW10MHz
winlink1000OduAirHssRfpEthChann
elBW20MHz
winlink1000OduAirHssRfpTdmChan
nelBW20MHz
winlink1000OduAirHssRfpEthChann
elBW40MHz
RADWIN 5000 HPMP User Manual
OID
Type
1.3.6.1.4.1.4458.1000.1.5.3
Integer
0
1.3.6.1.4.1.4458.1000.1.5.3
Integer
1
1.3.6.1.4.1.4458.1000.1.5.3
Integer
2
1.3.6.1.4.1.4458.1000.1.5.4
Integer
0.1
1.3.6.1.4.1.4458.1000.1.5.4
Integer
0.2
1.3.6.1.4.1.4458.1000.1.5.4
Integer
0.3
1.3.6.1.4.1.4458.1000.1.5.4
Integer
0.4
Integer
0.5
1.3.6.1.4.1.4458.1000.1.5.4
Integer
0.6
1.3.6.1.4.1.4458.1000.1.5.4
Integer
0.7.1.1
1.3.6.1.4.1.4458.1000.1.5.4
Integer
0.7.1.2
1.3.6.1.4.1.4458.1000.1.5.4
Integer
0.7.1.3
1.3.6.1.4.1.4458.1000.1.5.4
Integer
0.7.1.4
1.3.6.1.4.1.4458.1000.1.5.4
Integer
0.7.1.5
1.3.6.1.4.1.4458.1000.1.5.4
Integer
0.7.1.6
1.3.6.1.4.1.4458.1000.1.5.4
Integer
0.7.1.7
1.3.6.1.4.1.4458.1000.1.5.4
Integer
0.7.1.8
Release 3.5.70
Description
RO
Link working mode as a result of comparing
versions of both sides of the link. Possible
modes are: Unknown ‐ no link Normal ‐ versions
on both sides are identical with full
compatibility with restricted compatibility or
versions on both sides are different with
software upgrade or versions incompatibility.
RO
Major link interface version
RO
Minor link interface version
RW Required Hub Site Synchronization operating
state. For HssSyncUnits : For hssISU :[2 7] For
hssGSU :[2 6] For HBS: [2 3 4 5]
RO
Current Hub Site Synchronization operating
state.
RO
Hub Site Synchronization sync status.
RO
Hub Site Synchronization external pulse
detection status. In GSS mode: if generating
then 1PSP is auto generated by the GSS Unit. if
generatingAndDetecting then 1PSP is generated
by GPS satellites signal.
RO
Hub Site Synchronization external pulse type.
RW Hub Site Synchronization required external
pulse type. Valid values for read write:
{typeA(2) typeB(3) typeC(4) typeD(5) typeE(6)
typeF(7)}. Valid value for read only:
{notApplicable(1)}.
N/A ODU Radio Frame Patterns (RFP) Table.
N/A ODU RFP Table entry. INDEX {
winlink1000OduAirHssRfpIndex }
RO
ODU RFP Table index. The index represent the
Radio Frame Pattern: typeA(2) typeB(3)
typeC(4) typeD(5) typeE(6).
RO
Represents the compatibility of Ethernet service
under Channel BW of 5MHz in the specific
Radio Frame Pattern.
RO
Represents the compatibility of TDM service
under Channel BW of 5MHz in the specific
Radio Frame Pattern.
RO
Represents the compatibility of Ethernet service
under Channel BW of 10MHz in the specific
Radio Frame Pattern.
RO
Represents the compatibility of TDM service
under Channel BW of 10MHz in the specific
Radio Frame Pattern.
RO
Represents the compatibility of Ethernet service
under Channel BW of 20MHz in the specific
Radio Frame Pattern.
RO
Represents the compatibility of TDM service
under Channel BW of 20MHz in the specific
Radio Frame Pattern.
RO
Represents the compatibility of Ethernet service
under Channel BW of 40MHz in the specific
Radio Frame Pattern.
C‐46