ODU/HSS Unit Connection Pinout
6. If further ODUs are required, observe the convention that additional even 
numbered units are populated in descending order from SYNC 9 and odd 
numbered HSS units are populated in ascending order from SYNC 2.
If an ODU is disconnected from an HSS unit, then all remaining ODUs must 
be moved up or down to maintain the connectivity.
Note
Condition 2: Total HSS Cable Length
The total path of the HSS sync pulse must not exceed 300m. This applies no matter how many 
HSS units are used. To illustrate the method for calculating the sync pulse path length we 
show three examples. For our purpose, let:
Lmn denote the length of the ODU‐HSS unit cable at SYNC n on HSS unit m
Hm be the length of the cable joining HSS unit m to HSS unit m+1
One HSS unit with five collocated ODUs
=
+
2 L
PathLength
L
11
Two cascaded HSS units as shown in Figure 14‐4
=
+
2 L
PathLength
L
11
2
+
+
2 L
+
L
H
15
1
29
Three cascaded HSS units as shown in Figure 14‐5
=
+
2 L
PathLength
L
11
2
+
+
2 L
+
L
H
15
1
29
+
2 L
+
2 L
+
H
2
32
33
ODU/HSS Unit Connection Pinout
See Table
B‐3.
Sector Configuration and HSS
The Hub Site Synchronization Settings dialog box appears in the HBS Site Configuration 
window.
RADWIN 5000 HPMP User Manual
+
2
+
2 L
L
12
13
14
+
2
+
2 L
L
12
13
14
2
+
2
+
L
L
L
28
27
26
+
2
+
2 L
L
12
13
14
2
+
2
+
2 L
L
L
28
27
2 L
+
L
34
35
Release  3.5.70
+
L
15
+
+
+
26
14‐5