Radwin 5000 HPMP User Manual page 234

5000 series point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Example 3
Since all unused downlink slots are available to the busy HSU, the utilization graphs for this 
case are very similar to those of Example 1 and we will not repeat them all. The main 
difference is in the sector utilization:
Figure 10‐12: Sector Utilization ‐ Example 2
The downlink utilization is higher than for Example 1, reflecting the fact that the HBS must 
spend proportionally more time checking the inactive HSUs.
Similarly, the Sector relative HSU downlink utilization is higher by the same amount.
Example 3
Downlink
Uplink
allocation
allocation
Busy HSU 1 TS, others take all 
All HSUs 2 TS
remaining TS
In this case, we are deliberately "starving" the busy HSU, by allocating it one uplink time slot 
and dividing the rest between the inactive HSUs. The situation is shown in Figure
RADWIN 5000 HPMP User Manual
Purpose
Busy HSU "starved" in uplink direction
Release  3.5.70
10‐13.