Private MIB Parameters
Table C‐3: Private MIB Parameters ‐ HSU (Sheet 10 of 33)
Name
winlink1000OduAirHssAssociatedC
UTableEntry
winlink1000OduAirHssAssociatedC
UIndex
winlink1000OduAirHssAssociatedC
UDescription
winlink1000OduAirHssSyncStatusEt
h
winlink1000OduAirHssEthVLANTag
winlink1000OduAirHssHSMIPAddre
ss
winlink1000OduAirHssDelayToHSM
winlink1000OduAirHssSyncAcquisiti
onSeconds
winlink1000OduAirHssHSMIPv6Add
ress
winlink1000OduAirLockRemote
winlink1000OduAirAntennaGain
winlink1000OduAirFeederLoss
winlink1000OduAirMaxAntennaGai
n
winlink1000OduAirMinAntennaGai
n
winlink1000OduAirMaxEIRP
winlink1000OduAirAntennaGainCo
nfigSupport
winlink1000OduAirAntennaType
winlink1000OduAirRssBalance
winlink1000OduAirTotalTxPower
RADWIN 5000 HPMP User Manual
OID
Type
1.3.6.1.4.1.4458.1000.1.5.4
Integer
1
1.3.6.1.4.1.4458.1000.1.5.4
Integer
2
1.3.6.1.4.1.4458.1000.1.5.4
Integer
3
1.3.6.1.4.1.4458.1000.1.5.4
Integer
4
1.3.6.1.4.1.4458.1000.1.5.4
Integer
5
1.3.6.1.4.1.4458.1000.1.5.4
Integer
6
1.3.6.1.4.1.4458.1000.1.5.4
Integer
7
1.3.6.1.4.1.4458.1000.1.5.4
Integer
8
1.3.6.1.4.1.4458.1000.1.5.4
Integer
9
1.3.6.1.4.1.4458.1000.1.5.5
Integer
0
Release 3.5.70
Description
N/A Associated Ethernet HSS Clients Table Entry. 
Releant for Ethernet HSS Masters only.   INDEX { 
winlink1000OduAirHssAssociatedCUIndex } 
RO
Associated Ethernet HSS Clients Table Index. 
Releant for Ethernet HSS Masters only. 
RO
Holds Associated Ethernet HSS Clients 
Description in compress format:   IP Delay 
Compatibility Ethernet Speed  Ethernet Rx rate  
IPv6 
RO
Ethernet HSS Client Synchronization Level 
RW Ethernet HSS VLan Tag:    The least significate 
decimal digit is the VLan Priority(0‐6)    and the 
rest of the digits represents VLan ID (2‐4094) 
RO
HSMs IP address. Relevant for HSC synchronized 
over Ethernet. 
RO
Delay in microseconds to HSM. Relevant for HSC 
synchronized over Ethernet. 
RW Accumulated quantity of seconds in clock 
acquisition while connected to current HSM 
RO
HSMs IPv6 address. Relevant for HSC 
synchronized over Ethernet. 
RW This parameter enables locking the link with a 
specific ODU.    The following values can be set:    
Unlock (default) ‐ The ODU is not locked on a 
specific remote ODU. Unlock can only be 
performed when the link is not connected.    
Lock ‐ The ODU is locked on a specific remote 
ODU. Lock can only be performed when the link 
is active. 
RW Current Antenna Gain in 0.1 dBi resolution. User 
defined value for    external antenna.   Legal 
range: 
MinAntennaGain<AntennaGain<MaxAntennaG
ain. 
RW Current Feeder Loss in 0.1 dBm resolution. User 
defined value for    external antenna. 
RO
Maximum allowed Antenna Gain in 0.1 dBi 
resolution. 
RO
Minimum allowed Antenna Gain in 0.1 dBi 
resolution. 
RO
Maximum EIRP value as defined by regulation in 
0.1 dBm resolution. 
RO
Antenna Gain Configurability  options are 
product specific: supported  not supported. 
RW External Antenna Type: Monopolar or Bipolar. 
RO
RSS balance. Relation between RSS in radio 1 
and RSS in radio 2.   ‐2 : Radio 2 RSS is much 
stronger than Radio 1 RSS.   ‐1 : Radio 2 RSS is 
stronger than Radio 1 RSS.   ‐0 : Radio 2 RSS is 
equal to Radio 1 RSS.   1  : Radio 1 RSS is stronger 
than Radio 2 RSS.   2  : Radio 1 RSS is much 
stronger than Radio 2 RSS. 
RO
Total Transmit Power in dBm. This is a nominal 
value While the actual transmit power includes 
additional attenuation. 
C‐48