Radwin 5000 HPMP User Manual page 457

5000 series point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Private MIB Parameters
Table C‐2: Private MIB Parameters ‐ HBS (Sheet 33 of 33)
Name
winlink1000HsuAirAlignmentLastRe
portMcsIndexDown
winlink1000HsuAirAlignmentLastRe
portState
winlink1000HsuServiceCommandSt
r
winlink1000HsuServiceHsuType
winlink1000HsuServiceHsuLevel
winlink1000HsuEthernetPoESuppor
ted
winlink1000HsuEthernetPoETempe
rature
winlink1000HsuEthernetPoEEquCo
nsumption
winlink1000HsuEthernetPoEEquVol
tage
winlink1000GeneralTrapDescription 1.3.6.1.4.1.4458.1000.100.1 DisplayString
winlink1000GeneralTrapSeverity
winlink1000GeneralCookie
winlink1000GeneralEcChangesCoun
ter
winlink1000GeneralTelnetSupport
winlink1000GeneralWISupport
winlink1000GeneralSNMPSupport
RADWIN 5000 HPMP User Manual
OID
Type
1.3.6.1.4.1.4458.1000.100.2 Integer
1.3.6.1.4.1.4458.1000.100.3 DisplayString
1.3.6.1.4.1.4458.1000.100.4 Integer
1.3.6.1.4.1.4458.1000.100.5 Integer
1.3.6.1.4.1.4458.1000.100.6 Integer
1.3.6.1.4.1.4458.1000.100.7 Integer
Release 3.5.70
Description
RO
MCS index of the link in the downlink direction. 
RO
State of the Evaluation    1 Finished successfully    
2 Partial Evaluation (Timeout Exceeded)    3 
Evaluation Aborted (Timeout Exceeded)    4 
Evaluation aborted (Unstable Antenna)    5 
Evaluation aborted (Sync Lost)    6 Evaluation 
aborted (External command)    7 Evaluating. 
RW Ability to perform special command in the HSU.   
Format (string): Operation  Param1  Param2 ....| 
ParamN. 
RW HSU type (1 = Fixed  2 = Stationary  3 = Mobile  4 
= Transport) 
RW HSU level (1 .. 4) 
RO
Indicated if this HSU has special port for PoE 
devices.
RO
Holds the temperature (Celsius) of the POE 
component. 
RO
Holds the consumption of the connected 
equipment (milliampere). 
RO
Holds the voltage of the connected equipment 
(Volt). 
RO
Trap's Description. Used for Trap parameters. 
RO
Trap's Severity. Used for Trap parameters. 
RW Reserved for the Manager application provided 
with the product  used for saving user 
preferences affecting ODU operation. 
RO
This counter is initialized to 0 after a device 
reset and is incremented upon each element 
constant write operation   via SNMP or Telnet. 
RW Enable/Disable Telnet protocol. 
RW Enable/Disable Web Interface protocol.     
Mandatory Disabled ‐ No option to enable the 
feature.     Mandatory Enabled ‐ No option to 
disable the feature. 
RW Enable/Disable SNMP protocols 
C‐38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents