Calculations - Radwin 5000 HPMP User Manual

5000 series point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Calculations

Maximum linear input power (used to calculate minimum distance)
Antenna gain and cable loss for ODU with integrated antenna
Available Channel Bandwidths
Calculations
EIRP
=
+
EIRP
TxPower
AntennaGain
Expected RSS and Fade Margin
=
ExpectedRSS
EIRP PathLoss
where:
Site A is the transmitting site
Site B is the receiving site
PathLoss is calculated according to the free space model,
=
32.45
+
20
PathLoss
arg
ExpectedFadeM
in
where Sensitivity is dependent on air‐rate.
Min and Max Range
MinRange is the shortest range for which 
MaxRange (with Adaptive checked) is the largest range for which 
ExpectedRSS
Sensitivity
link with adaptive rate this will be the actual behavior. 
MaxRange (for a given air‐rate) is the largest range for which 
ExpectedRSS
Sensitivity
Service
The Ethernet and configured TDM trunks throughput is calculated according to internal 
product algorithms.
Availability
The Service Availability calculation is based on the Vigants Barnett method which predicts the 
downtime probability based on a climate factor (C factor).
RADWIN 5000 HPMP User Manual
CableLoss
SiteA
+
AntennaGain
log
frequency
MHz
10
=
ExpectedRSS Sensitivity
ExpectedRSS
, at the highest air‐rate for which this relationship is true. In a 
+
RequiredFadeM
Release  3.5.70
SiteA
CableLoss
SiteB
SiteB
+
20
log
RequiredRange
10
MaxInputPower
arg
in
.
Km
 per air‐rate.
23‐2