Radwin 5000 HPMP User Manual page 481

5000 series point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Private MIB Parameters
Table C‐3: Private MIB Parameters ‐ HSU (Sheet 24 of 33)
Name
winlink1000IduTdmConfigEntry
winlink1000IduTdmConfigIndex
winlink1000IduTdmIfIndex
winlink1000IduTdmLineCoding
winlink1000IduTdmLoopbackConfig
winlink1000IduTdmLineStatus
winlink1000IduTdmCurrentTable
winlink1000IduTdmCurrentEntry
winlink1000IduTdmCurrentIndex
winlink1000IduTdmCurrentBlocks
winlink1000IduTdmCurrentDrops
winlink1000IduTdmCurrentTxClock
winlink1000IduTdmCurrentBlocksHi
gh
winlink1000IduTdmRemoteQual
winlink1000IduTdmRemoteQualEva
l
winlink1000IduTdmSrvEval
winlink1000IduTdmBackupAvailabl
eLinks
winlink1000IduTdmBackupTable
winlink1000IduTdmBackupEntry
winlink1000IduTdmBackupIndex
winlink1000IduTdmBackupMode
winlink1000IduTdmBackupCurrentA
ctiveLink
winlink1000IduTdmJitterBufferSize
RADWIN 5000 HPMP User Manual
OID
Type
Release 3.5.70
Description
N/A IDU TDM Links Configuration table entry.   
INDEX { winlink1000IduTdmConfigIndex } 
RO
Table index. 
RO
Link index in the interface table. 
RW This parameter applies to T1 trunks only. The 
parameter controls the line coding.   Setting the 
value to each of the indices applies to all.   A 
change is effective after the next open of the 
TDM service. 
RW Loop back configuration table. Each of the 
trunks can be set Normal  Line loop back or 
Reverse line loop back.   A change is effective 
immediately. 
RO
Line status. 
N/A IDU TDM Links Statistics table. 
N/A IDU TDM Links Statistics table entry.   INDEX { 
winlink1000IduTdmCurrentIndex } 
RO
Table index (Same as 
winlink1000IduTdmLineIndex). 
RO
Number of correct blocks transmitted to the 
line. 
RO
Number of error blocks transmitted to the line. 
RW TDM Transmit Clock. A change is effective after 
re‐activation of the TDM service. 
RO
High part of the 64 bits counter Current Blocks 
RO
Estimated average interval between error 
second events.    The valid values are 1‐2^31 
where a value of ‐1 is used to indicate an 
undefined state. 
RO
Estimated average interval between error 
second events during evaluation process.   The 
valid values are 1‐2^31 where a value of ‐1 is 
used to indicate an undefined state. 
RW Evaluated TDM service bit mask.   Setting this 
parameter to value that is bigger than the 
activated TDM service bit mask    will execute 
the evaluation process for 30 seconds.    Setting 
this parameter to 0 will stop the evaluation 
process immediately. 
RO
Number of TDM backup trunks. 
N/A IDU TDM Links Statistics table. 
N/A IDU TDM Links Statistics table entry.   INDEX { 
winlink1000IduTdmBackupIndex } 
RO
Table index. 
RW TDM backup mode: Enable or Disable  where 
the     main link is the air link or the external link.    
Changes will be effective immediatly. 
RO
TDM backup current active link: N/A      air link is 
active or external link is active. 
RW TDM Jitter Buffer Size.    The value must be 
between the minimum and the maximum TDM 
Jitter Buffer Size.      The units are 0.1 x 
millisecond. 
C‐62

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents