Private MIB Parameters
Table C‐3: Private MIB Parameters ‐ HSU (Sheet 2 of 33)
Name
winlink1000OduReadCommunity
winlink1000OduReadWriteCommu
nity
winlink1000OduTrapCommunity
winlink1000OduAdmSnmpAgentVe
rsion
winlink1000OduAdmRemoteSiteNa
me
winlink1000OduAdmSnmpAgentMi
norVersion
winlink1000OduAdmLinkPassword
winlink1000OduAdmSiteLinkPassw
ord
winlink1000OduAdmDefaultPasswo
rd
winlink1000OduAdmConnectionTy
pe
winlink1000OduAdmBackToFactory
SettingsCmd
winlink1000OduAdmIpParamsCnfg
winlink1000OduAdmVlanID
winlink1000OduAdmVlanPriority
winlink1000OduAdmSN
winlink1000OduAdmProductName
winlink1000OduAdmActivationKey
winlink1000OduAdmRmtPermitted
OduType
winlink1000OduAdmCpuID
RADWIN 5000 HPMP User Manual
OID
Type
1.3.6.1.4.1.4458.1000.1.1.1
DisplayString
5
1.3.6.1.4.1.4458.1000.1.1.1
DisplayString
6
1.3.6.1.4.1.4458.1000.1.1.1
DisplayString
7
1.3.6.1.4.1.4458.1000.1.1.1
Integer
8
1.3.6.1.4.1.4458.1000.1.1.1
DisplayString
9
1.3.6.1.4.1.4458.1000.1.1.2
Integer
0
1.3.6.1.4.1.4458.1000.1.1.2
DisplayString
1
1.3.6.1.4.1.4458.1000.1.1.2
DisplayString
2
1.3.6.1.4.1.4458.1000.1.1.2
Integer
3
1.3.6.1.4.1.4458.1000.1.1.2
Integer
4
1.3.6.1.4.1.4458.1000.1.1.2
Integer
5
1.3.6.1.4.1.4458.1000.1.1.2
DisplayString
6
1.3.6.1.4.1.4458.1000.1.1.2
Integer
7
1.3.6.1.4.1.4458.1000.1.1.2
Integer
8
1.3.6.1.4.1.4458.1000.1.1.2
DisplayString
9
1.3.6.1.4.1.4458.1000.1.1.3
DisplayString
0
1.3.6.1.4.1.4458.1000.1.1.3
DisplayString
1
1.3.6.1.4.1.4458.1000.1.1.3
DisplayString
2
1.3.6.1.4.1.4458.1000.1.1.3
Integer
3
Release 3.5.70
Description
RW Read Community String. This parameter always 
returns ***** when retrieving its value.   It is 
used by the Manager application to change the 
Read Community String.   The SNMP agent 
accepts only encrypted values. 
RW Read/Write Community String. This parameter 
always returns ***** when retrieving its value.   
It is used by the Manager application to change 
the Read/Write Community String.   The SNMP 
agent accepts only encrypted values. 
RW Trap Community String. This parameter is used 
by the Manager application to change the Trap 
Community String.   The SNMP agent accepts 
only encrypted values. 
RO
Major version of the SNMP agent. 
RO
Remote site name. Returns the same value as 
sysLocation parameter of the remote site. 
RO
Minor version of the SNMP agent. 
RW Link Password. This parameter always returns 
***** when retrieving its value.   It is used by 
the Manager application to change the Link 
Password.   The SNMP agent accepts only 
encrypted values. 
RW Site Link Password. This parameter always 
returns ***** when retrieving its value.   It is 
used by the Manager application to change the 
Link Password of the site.   The SNMP agent 
accepts only encrypted values. 
RO
This parameter indicates if the current Link 
Password is the default password. 
RO
This parameter indicates if the Manager 
application is connected to the local ODU   or to 
the remote ODU over the air. A value of 
'unknown' indicates community string 
mismatch. 
RW Back to factory settings Command. A change is 
effective after reset.    The read value is always 
0. 
RW ODU IP address Configuration. The format is: 
<IP_Address>|<Subnet_Mask>|<Default_Gatew
ay>| 
RW VLAN ID. Valid values are 1 to 4094.   Initial value 
is 0 meaning VLAN unaware. 
RW VLAN Priority. 0 is lowest priority  7 is highest 
priority. 
RO
ODU Serial Number 
RO
This is the product name as it exists at EC 
RW Activates a general key. 
RW Mobile Application: permitted partner OduType. 
RO
CPU ID 